Home » Industrial Flexible & Special Cable Products » Type 440 Composite Screened Cable (AS/NZS 2802) | 1.1/1.1 kV to 22/22 kV Class 2 3-Pilot Trailing & Reeling Mining Cable

Type 440 Composite Screened Cable (AS/NZS 2802) | 1.1/1.1 kV to 22/22 kV Class 2 3-Pilot Trailing & Reeling Mining Cable

AS/NZS 2802 Type 440 Class 2 composite screened trailing and reeling cable (1.1 kV to 22 kV; 6–300 mm²) engineered with heavy Class 2 R-EP-90 EPR insulation, composite tinned-copper/polyester phase screens (8.2–71 mm²/phase), three large interstitial pilot cores (1–35.7 mm² each), and a polyaramid-reinforced HD-85-PCP sheath for long open-cut feeder runs, trailing equipment, and heavy reeling duty.

Standard & Radial Class
AS/NZS 2802 — Class 2 Heavy Radial
Rated Voltage Range
1.1 kV, 3.3 kV, 6.6 kV, 11 kV & 22 kV
Core & 3-Pilot Layout
3 Composite-Screened Phases + 3 Pilots
Screen & Pilot Capacity
8.2–71 mm²/ph Screen | 1–35.7 mm² Pilots
Reinforced Sheath
HD-85-PCP + Polyaramid Braid Reinforcement
Operating Temp & Flame
−25 °C to +90 °C | C1 Flame Retardant
Engineering Datasheet: AS/NZS 2802 Type 440 (PDF, 6 Pages)

Application & Operating Conditions

AS/NZS 2802 Type 440 is a Class 2 composite screened trailing and reeling mining cable (1.1 kV to 22 kV, 6–300 mm²) incorporating three heavy-section interstitial pilot cores for long-distance open-cut power runs, pit-rim substation interconnects, draglines, shovels, and multi-channel interlocked reeling equipment.

Long Pit-Bench Feeder Runs

Generously sized interstitial pilots (up to 3 × 35.7 mm² on 300 mm²) minimize pilot-loop resistance drop across multi-kilometer open-cut bench runs and mobile skid substations.

Three-Channel Control & Earth-Continuity

Three independent elastomer-covered and proofed-tape pilots support earth-continuity tripping alongside two spare control, emergency-stop, or pilot-interlock circuits.

Polyaramid-Reinforced Class 2 Armouring

Full Class 2 R-EP-90 EPR insulation radials paired with polyaramid braid reinforcement inside a heavy-duty HD-85-PCP sheath withstand high reeling tension and abrasive pit rock.

Only Need a Single Central Pilot? Where standard single-pilot earth-continuity protection suffices, compare AS/NZS 2802 Type 409 (Class 2, 1 central pilot) or underground coal AS/NZS 1802 Type 240.

Cable Construction (AS/NZS 2802 Type 440)

Type 440 arranges three composite-screened Class 2 EPR power cores in trefoil with three elastomer-covered and proofed-tape pilot cores occupying the outer interstices beneath a polyaramid-reinforced HD-85-PCP jacket.

Layer / ComponentMaterial & AS/NZS 2802 Specification
1. Phase ConductorsFlexible stranded tinned annealed copper, three power cores (6 mm² to 300 mm²)
2. Conductor Barrier / ScreenPolyester barrier tape for 1.1/1.1 kV; extruded semiconductive conductor screen for 3.3 kV and above
3. Class 2 EPR InsulationWhite R-EP-90 EPR Class 2 compound (1.5–3.0 mm @ 1.1 kV; 3.0 mm @ 3.3 kV; 5.0 mm @ 6.6 kV; 7.6 mm @ 11 kV; 10.5 mm @ 22 kV)
4. Composite Earth ScreenComposite braid of tinned annealed copper wire and polyester yarn with Red, White, and Blue braid tracers (8.2–71 mm² per phase)
5. Three Interstitial PilotsThree elastomer-covered and proofed-tape tinned copper pilots disposed in the outer cable interstices (1–35.7 mm² each)
6. Polyaramid-Reinforced SheathHeavy-duty black HD-85-PCP sheath (3.8–11.1 mm) incorporating polyaramid braid reinforcement
Cross-section diagram of TEBAOFLEX AS/NZS 2802 Type 440 composite screened 3-pilot mining cable

Type 440 Cross-Section Geometry: Three composite-screened Class 2 EPR phase cores with Red/White/Blue tracer braids, balanced by three symmetrical interstitial pilot cores inside a heavy HD-85-PCP sheath.

3 Screened Phases 3 Interstitial Pilots

Technical Characteristics

Compliant with AS/NZS 2802 from 1.1 kV through 22 kV, Type 440 delivers high earth-screen fault capacity, multi-pilot versatility, and immersion-grade elastomer durability.

ParameterAS/NZS 2802 Rated Value
Manufacturing StandardAS/NZS 2802 (Reeling and trailing cables for mining and general use)
Voltage Grades & Sub-Types440.1 (1.1 kV) | 440.3 (3.3 kV) | 440.6 (6.6 kV) | 440.11 (11 kV) | 440.22 (22 kV)
Phase Screen Area (Per Phase)8.2 mm²/phase up to 71 mm²/phase (up to 213 mm² combined 3-phase copper screen area!)
Interstitial Pilot Sizing3 × 1.0 mm² (on 6 mm²) scaling up to 3 × 35.7 mm² (on 300 mm²)
Operating Temperature Range−25 °C min. installation to +90 °C max. continuous conductor temperature
Immersion & Flame PerformanceExcellent oil/water immersion stability, polyaramid anti-torsion reinforcement, C1 flame retardant

Specification, Screen & Pilot Data (47 Standard Sizes, 1.1 kV – 22 kV)

Unified electrical and dimensional tables combining conductor diameter, Class 2 EPR wall, AC impedance, per-phase copper screen area, individual pilot cross-section, overall diameter, and mass.

Type 440.1 — Rated Voltage: 1.1/1.1 kV (6 mm² to 300 mm² | 13 Sizes)
Area (mm²)Cond. Dia. (mm)Insul. (mm)AC Res. (Ω/km)React. (Ω/km)Volt Drop (mV/A·m)Cap. (μF/km)Screen (mm²/ph)Pilot Each (mm²)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
3 × 63.51.54.320.1417.490.2598.213.831.0150
3 × 104.61.52.580.1304.470.3148.21.53.833.3175
3 × 166.21.61.580.1182.740.3791034.037.3230
3 × 257.21.60.9510.1121.660.432124.54.340.3295
3 × 358.41.60.6980.1071.220.4931464.643.6350
3 × 509.71.70.5230.1040.9240.5261485.047.7425
3 × 7012.01.80.3460.09810.6230.5991612.55.454.0565
3 × 9513.32.00.2710.09640.4980.5912212.56.059.5695
3 × 12015.32.10.2100.09320.3980.6402513.756.465.2845
3 × 15017.22.30.1660.09280.3290.65237176.972.31065
3 × 18518.82.50.1370.09150.2850.65740227.477.81245
3 × 24021.72.80.1060.09050.2410.67258278.288.11610
3 × 30024.33.00.08490.08830.2120.7196335.78.895.51930
Type 440.3 — Rated Voltage: 3.3/3.3 kV (16 mm² to 300 mm² | 11 Sizes)
Area (mm²)Cond. Dia. (mm)Insul. (mm)AC Res. (Ω/km)React. (Ω/km)Volt Drop (mV/A·m)Cap. (μF/km)Screen (mm²/ph)Pilot Each (mm²)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
3 × 166.23.01.580.1312.750.2551435.347.3340
3 × 257.23.00.9510.1251.660.280154.55.650.4410
3 × 358.43.00.6980.1191.230.3111665.953.5475
3 × 509.73.00.5230.1140.9270.3471786.357.2555
3 × 7012.03.00.3460.1060.6270.4081912.56.662.6690
3 × 9513.33.00.2710.1020.5020.4392112.57.166.4785
3 × 12015.33.00.2100.09850.4020.4922813.757.472.0960
3 × 15017.23.00.1660.09540.3320.54132177.876.71130
3 × 18518.83.00.1370.09420.2880.58442228.282.31330
3 × 24021.73.00.1060.09060.2420.65948278.889.61615
3 × 30024.33.00.08490.08900.2130.7276335.79.497.71980
Type 440.6 — Rated Voltage: 6.6/6.6 kV (16 mm² to 300 mm² | 11 Sizes)
Area (mm²)Cond. Dia. (mm)Insul. (mm)AC Res. (Ω/km)React. (Ω/km)Volt Drop (mV/A·m)Cap. (μF/km)Screen (mm²/ph)Pilot Each (mm²)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
3 × 166.25.01.580.1432.750.1811736.458.2480
3 × 257.25.00.9510.1371.660.193194.56.761.7570
3 × 358.45.00.6980.1301.230.2122167.064.8645
3 × 509.75.00.5230.1240.9310.2342287.368.2730
3 × 7012.05.00.3460.1160.6320.2712312.57.773.8880
3 × 9513.35.00.2710.1130.5090.2923012.58.178.01020
3 × 12015.35.00.2100.1080.4090.3253213.758.583.21180
3 × 15017.25.00.1660.1050.3400.35446178.989.21410
3 × 18518.85.00.1360.1020.2940.38149229.393.61590
3 × 24021.75.00.1060.09810.2500.42653279.91011885
3 × 30024.35.00.08450.09590.2210.4677135.710.41092275
Type 440.11 — Rated Voltage: 11/11 kV (25 mm² to 185 mm² | 8 Sizes)
Area (mm²)Cond. Dia. (mm)Insul. (mm)AC Res. (Ω/km)React. (Ω/km)Volt Drop (mV/A·m)Cap. (μF/km)Screen (mm²/ph)Pilot Each (mm²)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
3 × 257.27.60.9510.1501.670.150244.58.175.9815
3 × 358.47.60.6980.1431.230.1633068.479.6930
3 × 509.77.60.5230.1360.9360.1783288.783.01025
3 × 7012.07.60.3460.1270.6380.2043512.59.188.71210
3 × 9513.37.60.2710.1240.5160.2194812.59.693.81385
3 × 12015.37.60.2100.1190.4180.2415313.759.998.71565
3 × 15017.27.60.1650.1140.3470.261561710.31031765
3 × 18518.87.60.1360.1110.3040.279562210.71081945
Type 440.22 — Rated Voltage: 22/22 kV (35 mm² to 95 mm² | 4 Sizes)
Area (mm²)Cond. Dia. (mm)Insul. (mm)AC Res. (Ω/km)React. (Ω/km)Volt Drop (mV/A·m)Cap. (μF/km)Screen (mm²/ph)Pilot Each (mm²)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
3 × 358.410.50.6980.1601.240.14753610.01021430
3 × 509.710.50.5230.1530.9440.15956810.31061550
3 × 7012.010.50.3460.1430.6480.1786012.510.71111755
3 × 9513.310.50.2710.1380.5270.1896212.511.11151890

Selection: Type 440 vs. Type 409 vs. Type 240

All three models utilize composite tinned-copper/polyester phase screens; selection is governed by pilot core count, voltage ceiling, and surface vs. underground coal mine standards.

Cable ModelPilot Architecture, Voltage Ceiling & Best-Fit Application
Type 440 (This Product)AS/NZS 2802 Class 2, 3 interstitial pilots (1–35.7 mm² each), rated 1.1 kV to 22 kV. Ideal for long open-cut feeder runs, dragline/shovel substations, and multi-pilot reeling systems.
Type 409 (AS/NZS 2802)Type 409 shares the same Class 2 1.1–22 kV ratings but replaces the three interstitial pilots with a single central extensible pilot for standard trailing machines.
Type 240 (AS/NZS 1802)For underground coal mine 3-pilot feeders up to 11 kV, specify AS/NZS 1802 Type 240.

Frequently Asked Questions (FAQ)

Technical answers covering Type 440 interstitial pilot sizing, per-phase screen ratings, and reeling capability.

Why are the three pilots in Type 440 scaled up to 35.7 mm² on larger cable sizes?

Open-cut pit bench runs from perimeter substations to shovel/dragline skids frequently span several kilometers. Scaling the three interstitial pilots proportionally with phase size (from 1 mm² on 6 mm² up to 35.7 mm² each on 300 mm²) maintains mechanical lay symmetry and low loop resistance over long runs.

How is the Screen Area column reported in the Type 440 specification tables?

Per the AS/NZS 2802 Type 440 datasheet, Screen Area is stated in mm² per phase (8.2 mm²/phase up to 71 mm²/phase), providing substantial per-core earth-fault current capacity across all three power phases.

Does Type 440 include anti-torsion reinforcement for reeling drums?

Yes. Type 440 incorporates an integral polyaramid yarn reinforcement braid within the heavy-duty HD-85-PCP outer sheath to resist tensile stretch and torsional twist in reeling and long trailing service.

Request a Quote for AS/NZS 2802 Type 440 3-Pilot Mining Cables

Specify your voltage rating (1.1 kV to 22 kV), conductor cross-section (6–300 mm²), sheath colour, and drum length for factory pricing.

Explore All Mining & Tunneling Cables
Product Model

Type 440 Class 2 (Sub-Types 440.1, 440.3, 440.6, 440.11, 440.22)

Standard

AS/NZS 2802

Voltage Rating

1.1/1.1 kV, 3.3/3.3 kV, 6.6/6.6 kV, 11/11 kV, 22/22 kV

Insulation Radial Class

Class 2 Heavy-Duty Radial Insulation (White R-EP-90 EPR, 1.5–10.5 mm wall)

Nominal Conductor Area

6–300 mm² (1.1 kV), 16–300 mm² (3.3 & 6.6 kV), 25–185 mm² (11 kV), 35–95 mm² (22 kV)

Conductor Material

Flexible stranded tinned annealed copper (3 power cores + 3 interstitial pilot cores)

Composite Earth Screen

Composite braid of tinned annealed copper wire & polyester yarn with Red/White/Blue tracers (8.2–71 mm²/phase)

Interstitial Pilot Cores

Three elastomer-covered & proofed-tape pilots in the outer interstices (1–35.7 mm² each)

Outer Sheath & Reinforcement

Heavy-duty black HD-85-PCP sheath (3.8–11.1 mm) incorporating polyaramid braid reinforcement

Operating Temperature & Flame

−25 °C min. installation to +90 °C max. continuous conductor, C1 flame performance