IEC 60245-4:2011 Flexible Rubber
TÜV Rheinland J 50687206
Issued 22 Aug 2025 for approved 60245 IEC 66 flexible rubber power cable models.
Open Full PDFTEBAOFLEX maintains verifiable third-party product approvals—including TÜV Rheinland (Certificate J 50687206), UL and cUL Component Recognition (File E556567), VDE, CE, Korea KTL, and 0.38/0.66 kV to 8.7/15 kV Coal Mine Safety (MA) certificates—supported by in-house partial discharge and AC high-voltage routine test reports for global EPC tenders.
Each third-party certificate covers specific cable series, voltage ratings, and standard editions. Use this engineering compliance matrix to match TEBAOFLEX credentials with your target market and connected product lines prior to tender submission.
| Certification / Approval | Reference Standard & ID | Approved Scope & Voltage Span | Applicable TEBAOFLEX Cable Lines |
|---|---|---|---|
| TÜV Rheinland Mark Cert No. J 50687206 | IEC 60245-4:2011 60245 IEC 66 (YCW / H07RN-F family) | Heavy-duty polychloroprene (PCP) sheathed flexible rubber power cables up to 450/750 V for mobile industrial equipment. | |
| UL & cUL Recognition File No. E556567 | UL 758 / CSA C22.2 No. 210 UL Portable & High-Temp Styles | Listed AWM high-temperature PTFE/FEP/Silicone lead wires, industrial control styles, and North American portable cords (300 V–600 V). | |
| VDE Product Approval European Standard Compliance | DIN VDE 0250 / EN 50525 | Selected low- and medium-voltage elastomer flexible, reeling, and trailing cable constructions for European OEMs and EPC projects. | |
| CE & Korea KTL EU LVD & Korean Market | EU Directive 2014/35/EU Korea Testing Laboratory (KTL) | Low-voltage industrial power, crane festoon, submersible pump, and offshore marine instrumentation cables for EU and Korean imports. | |
| Coal Mine Safety (MA) 6 Voltage Grades Certified | MT 818 / Coal Mine Safety Flame-Retardant Standard | Approved across 0.38/0.66 kV, 0.66/1.14 kV, 1.9/3.3 kV, 3.6/6 kV, 6/10 kV, and 8.7/15 kV underground & open-pit trailing cables. | |
| ISO 9001 / 14001 / 45001 Factory Management Systems | ISO 9001 (Quality), ISO 14001 (Environment), ISO 45001 (OHS) | Covers raw copper incoming inspection, rubber compounding, extrusion, continuous vulcanization, HV testing, and OEM export manufacturing. |
Click any certificate preview below to inspect the high-resolution scan or full multi-page PDF document. All files are grouped into international product approvals, voltage-specific mining safety certificates, and factory management credentials.
Issued 22 Aug 2025 for approved 60245 IEC 66 flexible rubber power cable models.
Open Full PDF
Issued 18 Sep 2026 for listed Appliance Wiring Material (AWM) styles.
Open Full PDF
Supports European OEM and project review for approved rubber and reeling models.
Inspect Scan
North American safety approval record for designated wire and portable cord styles.
Inspect Scan
Canadian standard compliance record for approved industrial and control styles.
Inspect Scan
Supports European Union customs clearance and project conformity files.
Inspect Scan
Korea Testing Laboratory approval for designated industrial cable specifications.
Inspect Scan
Flame-retardant flexible trailing cables for underground drills and auxiliary equipment.
Inspect Scan
Screened elastomeric mobile power cables with pilot/monitoring cores.
Inspect Scan
Heavy-duty longwall coal shearer, continuous miner, and roadheader power cables.
Inspect Scan
Semiconductive-screened EPR/PCP flexible trailing cables for mobile substations.
Inspect Scan
Approved for high-load tunnel boring machines, draglines, and mine power feeders.
Inspect Scan
Triple-extruded medium-voltage reeling and trailing cables for electric rope shovels.
Inspect Scan
Audited quality control from copper drawing and rubber compounding to final FAT.
Inspect Scan
Compliant environmental governance across vulcanization and material processing.
Inspect Scan
Workplace safety management for heavy braiding, extrusion, and HV testing lines.
Inspect Scan
Recognizes proprietary R&D in anti-torsion reeling and specialty rubber formulations.
Inspect ScanEvery cable drum produced by TEBAOFLEX undergoes mandatory electrical, dimensional, and mechanical verification before dispatch. Medium-voltage reeling and trailing cables up to 35 kV are tested inside our shielded partial-discharge Faraday room with drum-traceable Factory Acceptance Test (FAT) reports.


| Inspection / Test Item | Reference Method & Criteria | Issued Record |
|---|---|---|
| 20°C Conductor DC Resistance | Verified per IEC 60228 Class 5 / Class 6 maximum Ω/km limits on 100% of finished drums. | Batch Routine Test Report |
| AC High-Voltage Withstand | Power-frequency dielectric test (e.g., 2.5 kV–3.5 U₀ for 5 min per IEC 60245 / IEC 60502) without breakdown. | HV Dielectric Certificate |
| Partial Discharge (MV Cables) | Tested at 1.5 U₀ to 1.73 U₀ in shielded room (DIN VDE 0250-813/814; typical discharge ≤ 5–10 pC). | MV PD Inspection Log |
| Hot-Set, Tensile & Oil Immersion | Elastomer cross-linking (≤ 175% load elongation), tensile strength (≥ 15 N/mm²), and IRM 902 oil test per IEC 60811. | Compound Type / Sample Record |
| Wall Thickness & Outer Diameter | Insulation eccentricity, inner/outer sheath minimum thickness, and OD tolerance checked against signed drawing. | Dimensional Inspection Sheet |
| Flame & Submersion Verification | Single/bunched vertical flame (IEC 60332-1-2 / 60332-3) and hydrostatic AD8 water-pressure verification where specified. | Compliance & Witness Report |
From initial vendor prequalification to final port customs clearance, TEBAOFLEX aligns certification copies, engineering drawings, and drum-level test reports with each milestone of your project schedule.
Submit factory audit files to register TEBAOFLEX in your approved vendor list (AVL) for mining, port, marine, or OEM supply.
Match exact cable models with applicable TÜV, UL, VDE, CE, or MA certificates alongside 2D cross-section drawings and ampacity data.
Review routine DC/HV/PD inspection reports, sheath marking photos, and optional third-party witness testing (SGS, BV, or TÜV) prior to dispatch.
Receive complete shipping documentation synchronized with drum flange plates, net/gross weights, and destination import rules.
Clear answers for EPC compliance engineers, QA/QC inspectors, and international cable distributors regarding certificate verification and factory testing.
No. Third-party product approvals—such as TÜV Rheinland J 50687206, UL/cUL File E556567, VDE, KTL, and Coal Mine Safety (MA) certificates—each govern specific model designations, conductor size ranges, and rated voltages, while ISO 9001, ISO 14001, and ISO 45001 govern our factory management system. Always confirm your exact cable model and voltage with our engineers before specifying sheath certification marks.
You can download the complete multi-page PDF documents directly from this page (TÜV Rheinland Certificate No. J 50687206 and UL/cUL File No. E556567) and verify the certificate or file numbers on the official TÜV Rheinland Certipedia and UL Product iQ online databases.
Yes. Every confirmed production order includes a drum-traceable Factory Acceptance Test (FAT) / routine test report covering 20°C conductor DC resistance, AC high-voltage dielectric testing, insulation resistance, dimensional checks, and partial discharge records for medium-voltage cables.
Yes. When specified in the purchase contract prior to production, TEBAOFLEX welcomes customer-appointed third-party inspectors (such as SGS, BV, Intertek, or TÜV) to witness on-site laboratory electrical, mechanical, and drum-length inspections at our factory before container loading.
Yes. Send us the tender technical schedule, target cable specification, project destination country, and submission deadline. Our engineers will compile the matching datasheets, 2D structure drawings, ISO credentials, and applicable product certificates for your bid package.
Standard export document sets include Commercial Invoice, Drum-by-Drum Packing List, Bill of Lading (B/L), Certificate of Origin (CO or regional FTA certificates such as Form E), ISPM-15 heat-treatment fumigation certificates for wooden drums, and signed factory routine test reports.
Send your cable specification, voltage rating, and destination standard. Our engineering team will confirm certificate applicability and prepare your project documentation within 24 hours.
Work directly with TEBAOFLEX engineers to verify operating duty, bending radius, and international standard specifications before production.
Work directly with TEBAOFLEX engineers to verify operating duty, bending radius, and international standard specifications before production.