Home » Industrial Flexible & Special Cable Products » (N)3GRDC5G-J/O Screened Rubber Festoon Cable | 0.6/1 kV EMC Crane Trolley & Drag Chain Cable

(N)3GRDC5G-J/O Screened Rubber Festoon Cable | 0.6/1 kV EMC Crane Trolley & Drag Chain Cable

(N)3GRDC5G-J/O EMC-screened round rubber festoon and drag-chain cable (0.6/1 kV, VDE 0250-812 reference) featuring Class 5 bare copper conductors, HEPR insulation, extruded GM1b inner sheath, an 80% tinned copper and synthetic fibre braid screen, and an oil- and UV-resistant black CR 5GM5 polychloroprene jacket for crane trolleys up to 240 m/min.

Standard & Designation
VDE 0250-812 Ref. | (N)3GRDC5G-J/O
Rated & Max. System Voltage
0.6/1 kV (Um = 1.2 kV | Test 2.5 kV)
Core & EMC Screen
Class 5 Bare Cu + 80% Tinned Cu/Fibre Braid
Insulation / Inner / Outer
HEPR / Rubber GM1b / Black CR 5GM5
Festoon Speed & Bend Radius
240 m/min | 4ר Fixed / 5ר Moving
Temperature & Resistance
−30 °C to +80 °C (+90 °C Cu) | Oil & UV
Available Range: 1×95–185, 3×16+3G2.5 to 3×95+3G16, 4G4–35, 24G2.5

Application & Operating Conditions

(N)3GRDC5G-J/O is a 0.6/1 kV EMC-screened heavy-duty rubber power and control cable engineered with reference to DIN VDE 0250-812 for high mechanical stress and frequent cyclic bending in a single plane. It operates reliably at festoon travel speeds up to 240 m/min across indoor dry, humid, and wet rooms as well as outdoor crane installations.

High-Speed Crane Festoon Trolleys

Built for motorized I-beam and C-track festoon trolley systems on ship-to-shore (STS) container cranes, RTGs, steelworks ladle cranes, and bulk material handling bridges running up to 240 m/min.

VFD Drives & Linear Drag Chains

Symmetrical 3+3 split-earth cores and an 80% tinned copper/synthetic braid suppress electromagnetic interference on inverter-fed hoist and travel motors in unidirectional drag chains (5ר min. bend).

Wet, Oily & Outdoor Port Duty

The black CR 5GM5 polychloroprene outer sheath resists mineral oils (EN 60811-404), UV radiation, coastal salt mist, and vertical flame spread (IEC 60332-1-2) from −30 °C to +80 °C in moving service.

Mechanical Bending Plane Notice: (N)3GRDC5G-J/O is specifically constructed for frequent cyclic bending in one direction (single bending plane), such as suspended festoon loops and linear energy chains. For vertical gravity-fed spreader baskets or multi-plane torsional twisting, consult our Port, Crane & Festoon Cables engineering catalog.

Cable Construction (DIN VDE 0250-812 Reference)

Constructed with a dual-sheath elastomer core-locking architecture, (N)3GRDC5G-J/O combines Class 5 bare copper conductors and 90 °C HEPR insulation inside a pressure-extruded GM1b rubber inner sheath, an 80% hybrid tinned copper/synthetic braid screen, and an abrasion-resistant 5GM5 outer jacket.

LayerMaterial & Engineering Specification
1. ConductorElectrolytic bare copper wire, finely stranded Class 5 flexible per DIN EN 60228 / IEC 60228
2. InsulationHigh-grade ethylene-propylene elastomer (HEPR), rated for +90 °C continuous conductor temperature and low dielectric loss under PWM inverter voltage spikes
3. Core Identification-J version: Green-yellow protective earth (PE / split 3G) + black cores with white numbers
-O version: Without green-yellow protective conductor (single-core feeder cables 1×95, 1×185)
4. Inner SheathPressure-extruded rubber compound GM1b filling core interstices to stabilize core lay and prevent corkscrewing under rapid trolley acceleration
5. EMC Braid ScreenHybrid braid of tinned copper wires + synthetic reinforcing fibres over inner sheath; approx. 80% optical coverage for flex-fatigue endurance and low transfer impedance
6. Outer SheathHeavy-duty polychloroprene elastomer (CR compound 5GM5), colour black; flame-retardant, oil-resistant, UV-stabilized, and weather-resistant
Cross-sectional diagram of TEBAOFLEX (N)3GRDC5G-J/O 0.6/1 kV screened festoon cable comparing 3+3 symmetrical VFD power cores and 4-core control/power designs

Cross-Sectional Comparison: Symmetrical 3+3 VFD motor supply geometry (e.g., 3×50 + 3G10, left) places three split earth cores in the outer interstices to balance capacitive coupling, alongside 4G / 24G multi-core power and control constructions (right).

Technical Characteristics

Electrical, thermal, dynamic mechanical, and environmental test parameters for (N)3GRDC5G-J/O cables are rated at Uo/U = 0.6/1 kV (maximum three-phase system voltage 1.2 kV, AC test voltage 2.5 kV) with a tight 5ר moving bend radius and 15 N/mm² dynamic tensile capacity.

ParameterRated Value / Applicable Standard
Reference Design StandardDIN VDE 0250-812 (with reference to)
Nominal Voltage (Uo / U)0.6 / 1 kV AC
Max. Permitted Three-Phase Voltage (Um)1.2 kV
AC Routine Test Voltage2.5 kV
Max. Conductor Operating Temperature+90 °C
Permitted Outer Cable Temp. (Moved / Flexing)−30 °C to +80 °C
Minimum Bending Radius (Fixed Installation)4 × Ø (cable outer diameter)
Minimum Bending Radius (Moving Application)5 × Ø (unidirectional bending in festoon trolleys and drag chains)
Max. Dynamic Tensile Stress at Conductor15 N/mm² (see part-specific Fzd ratings from 240 N to 4,275 N below)
Max. Operating Speed (Festoon System)240 m/min
EMC Braid Optical CoverageApprox. 80% (tinned copper wire + synthetic fibre)
Flame RetardancyDIN VDE 0482-332-1-2 / IEC 60332-1-2
Oil ResistanceDIN EN 60811-404 (IEC 60811-404)
UV, Weather & ConformityUV-resistant; suitable for dry, humid, wet indoor rooms & outdoor crane service; CE compliant

Specification & Dimensional Data

Dimensional, DC conductor resistance, dynamic tensile force (Fzd), and weight specifications cover 10 standard (N)3GRDC5G-J/O constructions spanning single-core main feeders, 3+3 symmetrical VFD motor cables, 4-core power cables, and 24-core festoon control cables.

Sub-Series ArchitectureType CodeCross-Section RangeApprox. OD RangeDynamic Pull FzdPrimary Crane Duty
Single-Core Power Feeder(N)3GRDC5G-O1×95 mm², 1×185 mm² (2 sizes)24 – 31 mm1,425 – 2,775 NHigh-current single-phase / trefoil crane bus & DC link feeders
Symmetrical 3+3 VFD Supply(N)3GRDC5G-J3×16+3G2.5 to 3×95+3G16 (5 sizes)26 – 49 mm757 – 4,275 NInverter-driven hoist, trolley & gantry motors (EMC low shaft current)
4-Core Crane Power(N)3GRDC5G-J4G4 mm², 4G35 mm² (2 sizes)19 – 36 mm240 – 2,100 NAuxiliary drives, brakes, hydraulic units & conveyor motors
Multi-Core Festoon Control(N)3GRDC5G-J24G2.5 mm² (1 size)33 mm900 NEMI-protected PLC control, limit switches & trolley signaling
Core Configuration (mm²)VersionMax. Rl (Ω/km)Ø Min. (mm)Ø Max. (mm)Ø Approx. (mm)Moving Bend 5ר (mm)Dynamic Pull Fzd (N)Cu Index (kg/km)Net Weight (kg/km)
1 × 95-O0.2062124241201,4251,0651,190
1 × 185-O0.1062831311552,7751,9692,172
3 × 16 + 3G2.5-J1.2102426261307576421,170
3 × 35 + 3G6-J0.5543033331651,5751,3022,050
3 × 50 + 3G10-J0.3863639391952,2501,9732,875
3 × 70 + 3G10-J0.2724043432153,1502,5553,685
3 × 95 + 3G16-J0.2064649492454,2753,5774,956
4G4-J4.95016191995240381579
4G35-J0.5543336361802,1001,5772,348
24G2.5-J7.9803133331659008051,600

Table Legend: Rl = Max. DC conductor resistance at 20 °C (Ω/km); Ø Min. / Ø Max. / Ø Approx. = Outer diameter tolerance window and nominal outer diameter (mm); Fzd = Maximum permissible dynamic tensile force (N) based on 15 N/mm² active copper cross-section; Net Weight = Approximate cable weight per 1,000 m. Custom core counts and cross-sections available on request.

Selection, EMC Grounding & Festoon Installation Guidelines

Proper core geometry selection and 360-degree shield termination are critical to achieving full EMC compliance and multi-year flex life on high-speed crane festoons (up to 240 m/min) and inverter-fed linear drag chains.

Engineering CriterionRecommended Practice for (N)3GRDC5G-J/O
VFD Motor Drives (3+3 Split Earth)Select symmetrical 3×16+3G2.5 through 3×95+3G16 sizes for PWM frequency-converter hoist and gantry motors. Splitting the protective earth into three interstitial green-yellow cores balances phase-to-earth capacitance and mitigates destructive motor bearing currents.
360° EMC Screen TerminationTerminate the 80% tinned copper braid at both the inverter cabinet and motor terminal box using 360-degree Compression EMC brass cable glands rather than twisted pigtail leads to maintain low high-frequency transfer impedance.
Festoon Saddle & Drag-Chain RadiusSize trolley cable saddles and drag-chain bend shoes so the inner bend radius is never tighter than 5 × Ø max in moving service (4 × Ø in fixed clamping zones), and keep peak acceleration tension below the listed Fzd [N] rating.
Alternative Sheath & Unscreened OptionsFor unscreened rubber festoon circuits without VFD EMI exposure, compare our (N)GRDGÖU 0.6/1 kV Rubber Festoon Cable; for halogen-free polyurethane crane duty, see (N)12YRDC11Y-J/O Screened PUR Crane Cable.

Frequently Asked Questions (FAQ)

Key engineering answers covering DIN VDE type code nomenclature, -J versus -O core coding, dynamic pull limits, and custom manufacturing options for (N)3GRDC5G-J/O cables.

What does the German DIN VDE code (N)3GRDC5G-J/O stand for?

(N) indicates construction based on DIN VDE standards (VDE 0250-812 reference); 3G denotes 90 °C HEPR ethylene-propylene rubber core insulation; RD designates a round cable engineered for dynamic crane festoon and drag-chain flexing; C specifies the overall tinned copper EMC braid screen; 5G denotes the heavy-duty polychloroprene (CR 5GM5) rubber outer sheath; -J includes a green-yellow protective earth core, while -O omits the green-yellow earth core (used on single-core 1×95 and 1×185 power feeders).

Why is the EMC braid made from both tinned copper wire and synthetic fibre?

Pure metallic copper braids can work-harden and snap strands when subjected to millions of rapid unidirectional bending cycles at 240 m/min and 5ר tight radii. Interweaving high-tenacity synthetic fibres with tinned copper strands (~80% optical coverage) absorbs mechanical shear stress over the extruded GM1b inner sheath while preserving reliable high-frequency EMI shielding.

How is the maximum dynamic tensile load (Fzd) calculated for crane trolleys and drag chains?

Per DIN VDE 0250-812 mechanical design rules, maximum dynamic conductor stress is capped at 15 N/mm² across the active phase conductor cross-section. For example, 3×50 + 3G10 (150 mm² phase copper) yields Fzd = 2,250 N, whereas 1×185 yields Fzd = 2,775 N.

What parameters are needed to request a custom quotation or project drum length?

Provide your required core configuration (e.g., 3×35+3G6, 1×185, or 24G2.5), individual cut lengths or continuous drum lengths, festoon travel speed or drag-chain inner bend radius, ambient temperature range, and destination port. TEBAOFLEX supplies custom cut-to-length export wooden drums and routine test reports.

Need a Custom (N)3GRDC5G-J/O Festoon or Drag-Chain Cable Quotation?

Share your cross-section, VFD motor power, festoon loop length, and delivery schedule with TEBAOFLEX engineering sales for factory-direct pricing and technical datasheet confirmation.

Explore All Port, Crane & Festoon Cables
Product Model

(N)3GRDC5G-J / (N)3GRDC5G-O

Standard

With reference to DIN VDE 0250-812

Rated Voltage

0.6/1 kV (Max. three-phase operating voltage Um = 1.2 kV; Test voltage 2.5 kV)

Conductor Material

Class 5 flexible bare copper (IEC 60228 / DIN EN 60228)

Insulation Material

HEPR high-grade ethylene-propylene rubber

Inner Sheath

Extruded GM1b rubber compound

EMC Screen

Tinned copper braid + synthetic fibre (80% optical coverage)

Outer Sheath

Black polychloroprene rubber (CR 5GM5), oil-resistant (EN 60811-404) & UV-resistant

Operating Temperature

−30 °C to +80 °C (moved outer cable surface); +90 °C max. conductor temperature

Minimum Bending Radius

4 × Ø (fixed installation) / 5 × Ø (moving festoon & drag chain)

Mechanical Duty

Festoon speed up to 240 m/min; max. dynamic conductor tensile stress 15 N/mm²