Home » Products » DLO 2kV Flexible Diesel Locomotive Cable

DLO 2kV Flexible Diesel Locomotive Cable

DLO 2kV flexible diesel locomotive cable with Class I stranded tinned-copper conductor, EPR insulation and a black XL-CPE jacket for locomotives, switchgear, mining equipment and heavy-duty flexible power connections.

What Is DLO Cable?

DLO cable, short for diesel locomotive cable, is a flexible single-conductor power cable for 2 kV industrial connections. This construction uses a Class I flexible stranded tinned-copper conductor, EPR insulation and a black XL-CPE jacket. It is specified for diesel-electric locomotives, switchgear, mining and earth-moving equipment, motors, generators, battery systems and other heavy-duty power leads where routing flexibility and mechanical durability are important.

The cable carries a 2,000 V UL RHH/RHW-2 rating and a 1,000 V c(UL) RW90 rating for the listed construction. DLO is a cable family name, not permission for every installation. Engineers must confirm conductor size, ampacity, cable length, ambient temperature, route, movement, terminations, applicable code and required documentation. Read the DLO cable technical guide or ask the TEBAOFLEX special cable team to review the project specification.

  • UL RHH/RHW-2 rating: 2,000 V
  • c(UL) RW90 rating: 1,000 V
  • Temperature range: -40°C to +90°C
  • Conductor-size range: 14 AWG to 1111.1 kcmil
  • Minimum bending radius: 8 × overall cable diameter

How Is DLO Cable Constructed?

DLO 2 kV cable construction with stranded tinned-copper conductor, separator, EPR insulation and XL-CPE jacket
DLO 2 kV cable construction with flexible tinned-copper conductor, separator, EPR insulation and XL-CPE outer jacket.

The DLO 2 kV construction uses a Class I fully annealed flexible stranded tinned-copper conductor in accordance with AAR 589. A paper separator tape assists stripping, while the flame-retardant, lead-free cross-linked EPR insulation supports the electrical insulation system. The standard outer jacket is black, flame-retardant, sunlight-, ozone- and oil-resistant lead-free XL-CPE. Fully annealed bare copper and alternative jacket colours can be reviewed for project requirements.

DLO 2 kV Technical Information

ParameterConfirmed data
UL RHH/RHW-2 voltage rating2,000 V
c(UL) RW90 voltage rating1,000 V
Temperature range-40°C to +90°C
Minimum bending radius8 × overall cable diameter
Torsion endurance±180°/m for 5,000 cycles at -40°C; cable weight compensated to 18 m
Primary standardsUL 44; CSA C22.2 No. 38
Industry standardsICEA S-95-658; NEMA WC70; NEC
Flame performanceUL 2556 VW-1; IEEE 1202 / CSA FT4 for 1/0 AWG and larger
Additional complianceMSHA flame resistant; RoHS compliant

Product selection must confirm the required marking, conductor size, installation method and project compliance scope. Cable-tray use applies to sizes 1/0 AWG and larger only where the applicable installation requirements are met.

DLO Cable Size Chart

The following nominal dimensions and approximate net weights are listed for the supplied 2 kV DLO construction. Values are shown in dual units to support both North American and international project review.

14 AWG to 3/0 AWG

Size AWG / mm²StrandConductor OD in / mmInsulation in / mmJacket in / mmOverall diameter in / mmApprox. weight lb/1000 ft / kg/km
14 / 2.0819/.01470.070 / 1.80.045 / 1.10.015 / 0.40.20 / 5.130 / 45
12 / 3.3119/.01850.088 / 2.20.045 / 1.10.015 / 0.40.22 / 5.639 / 58
10 / 5.2627/240.117 / 3.00.045 / 1.10.015 / 0.40.25 / 6.456 / 83
8 / 8.3637/240.144 / 3.70.055 / 1.40.030 / 0.80.33 / 8.387 / 129
6 / 13.361/240.190 / 4.80.060 / 1.50.030 / 0.80.38 / 9.7131 / 195
4 / 21.1105/240.262 / 6.70.060 / 1.50.030 / 0.80.46 / 11.7202 / 301
2 / 33.6158/240.315 / 8.00.060 / 1.50.030 / 0.80.51 / 13.0285 / 424
1 / 42.4224/240.375 / 9.50.080 / 2.00.045 / 1.10.64 / 16.3417 / 621
1/0 / 53.5280/240.435 / 11.00.080 / 2.00.045 / 1.10.70 / 17.8494 / 735
2/0 / 67.4329/240.465 / 11.80.080 / 2.00.045 / 1.10.73 / 18.5587 / 874
3/0 / 85456/240.535 / 13.60.080 / 2.00.045 / 1.10.80 / 20.3718 / 1069

4/0 AWG to 1111.1 kcmil

Size kcmil / mm²StrandConductor OD in / mmInsulation in / mmJacket in / mmOverall diameter in / mmApprox. weight lb/1000 ft / kg/km
4/0 / 107551/240.581 / 14.80.080 / 2.00.045 / 1.10.84 / 21.3845 / 1258
262.6 / 133650/240.617 / 15.70.090 / 2.30.065 / 1.70.94 / 23.91050 / 1563
313.3 / 158777/240.671 / 17.00.090 / 2.30.065 / 1.71.00 / 25.31195 / 1778
373.7 / 189925/240.735 / 18.70.090 / 2.30.065 / 1.71.06 / 26.91384 / 2060
444.4 / 2251110/240.786 / 20.00.090 / 2.30.065 / 1.71.11 / 28.21634 / 2432
535.3 / 2711332/240.877 / 22.30.090 / 2.30.065 / 1.71.20 / 30.51925 / 2865
646.4 / 3271609/240.960 / 24.40.090 / 2.30.065 / 1.71.29 / 32.82307 / 3433
777.7 / 3941924/241.054 / 26.80.090 / 2.30.065 / 1.71.38 / 35.12728 / 4060
929.9 / 4752318/241.230 / 31.20.090 / 2.30.065 / 1.71.56 / 39.63570 / 5313
1111.1 / 5622745/241.328 / 33.70.115 / 2.90.095 / 2.41.77 / 44.94232 / 6298

Where Is DLO Cable Used?

DLO cable is used for flexible single-conductor power connections in heavy equipment and industrial electrical systems. Common applications include:

  • Diesel-electric locomotive power leads
  • Switchgear, transformer and power-distribution connections
  • Mining and tunnelling equipment
  • Earth-moving machinery and mobile industrial equipment
  • Motor, generator and battery-system leads
  • Heavy-duty flexible power connections requiring the specified 2 kV construction

This product is a single-conductor power cable, not a multi-core trailing cable with integrated grounding or ground-check conductors. Review the Type W and DLO application guide when comparing flexible power-cable families.

How Do You Select the Correct DLO Cable?

Confirm the voltage and required markings

State the system voltage, destination market, installation method and required cable markings. The listed construction is rated 2,000 V as UL RHH/RHW-2 and 1,000 V as c(UL) RW90; verify that the required marking is appropriate for the project.

Calculate conductor size and ampacity

Select the conductor size from the design current, ambient temperature, grouping, duty cycle and installation conditions. DLO cable ampacity is installation-dependent and should not be chosen from a generic current value alone. Use the cable ampacity calculation guide as a planning reference, then confirm the result against the applicable code and engineering data.

Check cable length and voltage drop

Provide the complete circuit length and allowable voltage drop. Long power runs may need a larger conductor even when the thermal ampacity is sufficient.

Define routing and movement

Confirm fixed or flexible routing, bend locations, available space, pulling conditions, vibration, oils, sunlight and mechanical exposure. The listed minimum bending radius is 8 times the finished cable diameter; terminations and strain relief must also suit the selected size.

Specify documents and terminations

State the lug or connector arrangement, packing length, inspection requirements and documentation needed with the order. For more background on construction and sizes, see the DLO cable specification guide.

Can DLO Cable Replace Welding Cable?

DLO and welding cable can both be highly flexible, but the names do not make them interchangeable. Compare voltage rating, conductor and insulation system, markings, temperature, installation method and termination requirements before specifying either cable.

Selection pointDLO cableWelding cable
Typical purposeFlexible industrial power connections, locomotive and equipment leadsSecondary leads for welding equipment
Construction reviewConfirm 2 kV rating, marking and installation requirementsConfirm welding-duty requirements and permitted use
Selection ruleDo not substitute by cable name alone; review voltage, installation method, approvals, temperature, route and termination requirements.

How Do You Request a DLO Cable Specification and Price?

Send the conductor size, required length, system voltage, installation route, equipment type, ambient conditions, destination market, termination details and required documents. TEBAOFLEX can review bare-copper options, jacket colours, printed marking, packing length and project-specific documentation before quotation.

Frequently Asked Questions

What is DLO cable?

DLO means Diesel Locomotive Cable. This product is a flexible single-conductor power cable listed in the supplied data sheet for 2 kV RHH/RHW-2 applications, with EPR insulation and an XL-CPE jacket.

What DLO cable sizes are listed?

The supplied construction lists sizes from 14 AWG through 1111.1 kcmil. The size chart above provides conductor stranding, nominal dimensions and approximate cable weight for each listed size.

What is DLO cable ampacity?

Ampacity depends on the conductor size and actual installation conditions, including ambient temperature, cable grouping, routing and applicable code requirements. Submit the installation details for a project-specific review rather than selecting only from a generic current value.

Can I request a DLO cable data sheet and price?

Yes. Send the required size, length, application, destination and required approvals through the Request a Quote form so the applicable construction and documentation can be confirmed.

Can DLO cable be installed in cable tray?

For this listed construction, cable-tray use applies to sizes 1/0 AWG and larger only when the applicable installation requirements are met. Confirm the cable marking, tray method, fill, spacing, ampacity and local code before installation.

Can DLO cable replace welding cable?

Not by product name alone. DLO and welding cable are designed around different ratings and intended uses. Verify voltage, installation method, cable marking, temperature, route and termination requirements before considering any substitution.

Brand

TEBAOFLEX

Cable Model

DLO

Cable Type

Flexible Diesel Locomotive Power Cable

Rated Voltage

2 kV UL RHH/RHW-2; 1 kV c(UL) RW90

Conductor

Class I flexible stranded tinned copper; bare copper option

Core Configuration

Single conductor

Insulation / Sheath

EPR insulation; black XL-CPE jacket

Application

Locomotives, switchgear, mining, earth-moving equipment and flexible power leads

Temperature Range

-40°C to +90°C

Minimum Bending Radius

8 × overall cable diameter

Conductor Size Range

14 AWG to 1111.1 kcmil

Standards / Compliance

UL 44; CSA C22.2 No. 38; ICEA S-95-658; NEMA WC70; NEC; MSHA flame resistant; RoHS compliant

Engineering & Customization Capabilities

Configurable Cable Solutions for Demanding Industrial Applications

Application-Specific Engineering

Cable constructions can be configured according to voltage, installation method, operating environment and equipment requirements.

Flexible Conductor & Core Options

Conductor size, core configuration and cable construction can be selected to match power, control and signal requirements.

Shielding & EMC Options

Screening and shielding constructions are available for applications requiring signal integrity and electromagnetic compatibility.

Sheath Material Options

Rubber, PUR, PVC, silicone and other sheath solutions can be selected according to flexibility, temperature and environmental requirements.

Mechanical Protection Options

Reinforcement, armour and heavy-duty constructions can be provided where additional tensile, abrasion or mechanical protection is required.

Custom Sizes, Lengths & Configurations

Cable dimensions, conductor sizes, colours, markings, reel lengths and project-specific configurations can be reviewed for customization.

Project Support

Quality, Manufacturing & Export Support

From certification and cable testing to manufacturing and export delivery, TEBAOFLEX provides product-specific documentation, production support and shipment preparation for industrial cable projects.

01 / Documentation

Certifications & Quality Documentation

Quality management, product certification and compliance documentation can be reviewed according to product and project requirements.

TEBAOFLEX ISO 9001 quality management system certificate for industrial cable manufacturing
ISO 9001 Quality Management Quality management system documentation.
TEBAOFLEX VDE product certification for industrial and specialty cable products
VDE Product Certification Product certification and compliance documentation.
TEBAOFLEX UL cable certification and product compliance documentation
UL Certification Cable product compliance and certification documentation.
View Certifications & Documentation
02 / Testing

Cable Testing & Quality Inspection

Electrical, insulation and flame-performance testing supports quality verification for flexible, rubber, mining, industrial and specialty cable products according to applicable requirements.

TEBAOFLEX cable partial discharge and high voltage testing in shielded electrical test room
Partial Discharge & High-Voltage Testing Electrical testing supports insulation quality evaluation for applicable medium-voltage and specialty cable products.
TEBAOFLEX cable water immersion electrical testing equipment for insulation resistance and cable quality inspection
Water Immersion Electrical Testing Water-immersion testing supports evaluation of cable insulation and electrical performance under specified conditions.
TEBAOFLEX single cable vertical flame test chamber for flame retardant cable testing and quality inspection
Single Cable Vertical Flame Testing Flame testing supports evaluation of flame propagation performance for applicable cable constructions.
View Testing & Factory Videos
03 / Manufacturing

Cable Manufacturing & Processing

Production lines support planetary stranding and cabling, steel-wire armouring, take-up and reeling for heavy-duty, flexible and specialty cable constructions.

TEBAOFLEX heavy-duty cable planetary stranding and cabling production line for industrial and specialty cable manufacturing
Planetary Stranding & Cabling Planetary stranding equipment supports multi-core heavy-duty and flexible cable constructions.
TEBAOFLEX steel wire cable armouring machine for heavy-duty mining industrial and specialty cable manufacturing
Steel-Wire Cable Armouring Steel-wire armouring provides additional mechanical protection for applicable heavy-duty cable constructions.
TEBAOFLEX heavy-duty cable take-up and reeling production line for flexible rubber and industrial cable manufacturing
Cable Take-Up & Reeling Take-up and reeling equipment supports controlled handling of finished heavy-duty and specialty cable lengths.
View Cable Manufacturing Videos
04 / Export & Delivery

Export Packing & Delivery

Cable reel size, packing method, drum length and shipment preparation can be arranged according to cable dimensions, destination and handling requirements.

TEBAOFLEX industrial cable material flow and cable reel handling during production and packing
Material & Reel Handling Cable reels are prepared and handled according to product dimensions.
TEBAOFLEX industrial cable packing and export delivery preparation for overseas customers
Cable Packing Preparation Packing methods can be selected for project and export requirements.
TEBAOFLEX industrial cable reel container loading and export packing for international shipment
Container Loading Cable reels prepared for container loading and international shipment.
Discuss Packing & Delivery Requirements

Need a Project-Specific Cable Solution?

Share your voltage, conductor size, cable length, application and destination for review.

Request a Quote