RFOU vs BFOU Cable: Offshore Cable Comparison

RFOU vs BFOU: What’s the Difference?

Both RFOU and BFOU are offshore and marine power cables rated 0.6/1kV, manufactured to NEK 606. The key difference: RFOU is flame-retardant only (self-extinguishing, IEC 60332), while BFOU is fire-resistant (maintains circuit integrity during fire, IEC 60331). BFOU includes a mica glass tape fire barrier that RFOU does not have. This makes BFOU essential for fire-critical safety circuits and RFOU the economical choice for general offshore power distribution.

TEBAOFLEX manufactures both types. View RFOU product page and BFOU product page for specifications.

RFOU 0.6/1kV offshore power cable drum by TEBAOFLEX showing orange LSZH sheath
RFOU 0.6/1kV offshore cable — flame-retardant but not fire-resistant. For fire-critical circuits, use BFOU instead.

Designation Breakdown

ElementRFOUBFOU
R vs BR = Rubber/EPR insulatedB = Fire resistant (IEC 60331)
FFlexible conductorFlexible conductor
OOil-resistant sheathOil-resistant sheath
ULSZH outer sheathLSZH outer sheath
StandardNEK 606 / IEC 60502NEK 606 / IEC 60331
Fire BarrierNo mica glass tapeMica glass tape (yes)
RFOU vs BFOU cable material comparison showing fire barrier and insulation differences
Construction comparison: BFOU includes a mica glass tape fire barrier over each conductor — RFOU does not. This is the critical difference for fire survival.

Performance Comparison

PropertyRFOUBFOUAdvantage
Fire resistance (IEC 60331)NoYes (750-950°C, 90+ min)BFOU
Flame retardancyIEC 60332-3-22 Cat AIEC 60332-3-22 Cat ATie
Smoke densityIEC 61034 (>60%)IEC 61034 (>60%)Tie
Halogen contentZero halogen (LSZH)Zero halogen (LSZH)Tie
Voltage rating0.6/1kV0.6/1kVTie
Conductor temp90°C90°CTie
Oil resistanceGood (IR2)Good (IR2)Tie
Mechanical protectionSteel wire braidSteel wire braidTie
CostLower (reference)~20-30% higherRFOU
RFOU vs BFOU cable application comparison for general offshore power and fire-critical emergency systems
Application scenarios: RFOU for general offshore power distribution (left) vs BFOU for fire-critical emergency systems (right)

When to Choose RFOU

  • General power distribution: Non-fire-critical circuits don’t require fire resistance
  • Process equipment: Production equipment that will be shut down during emergency
  • Normal lighting: Non-emergency lighting circuits
  • HVAC: Standard ventilation and air conditioning
  • Motor power: LV motor supply for non-safety equipment
  • Cost optimization: RFOU is 20-30% less expensive — use where fire resistance isn’t required

When to Choose BFOU

  • Fire pumps: Must maintain power during fire — only BFOU (IEC 60331) guarantees this
  • Emergency lighting: Escape route lighting must remain lit during fire
  • ESD systems: Emergency shutdown requires fire-survivable power
  • Emergency generator output: Power must reach emergency switchboard during fire
  • Alarm/communication: Fire alarms and PA systems need continuous power
  • Mandatory by code: SOLAS and classification rules require IEC 60331 cable for critical safety circuits
RFOU vs BFOU technical specification comparison table showing fire resistance insulation and construction differences
Specification comparison: the only structural difference is the mica glass tape fire barrier — but it determines whether the cable survives a fire or merely self-extinguishes

Cost Comparison

RFOU is the baseline cost. BFOU costs 20-30% more due to:

  • Mica glass tape fire barrier material and wrapping process
  • More stringent testing (IEC 60331 fire test)
  • Additional quality control for fire-critical applications

Best practice: Use BFOU only where fire resistance is mandatory, and RFOU for all other circuits. This optimizes cost while meeting all safety requirements.

Can RFOU and BFOU Be Interchanged?

BFOU can replace RFOU — it has all RFOU properties plus fire resistance. But this adds unnecessary cost for non-critical circuits.

RFOU cannot replace BFOU — RFOU lacks the fire barrier and IEC 60331 rating. Substituting RFOU for BFOU in fire-critical circuits violates classification rules and compromises safety.

Summary: Which Cable Should You Choose?

If your application is…Recommended cable
General offshore power distributionRFOU
Process equipment, motors, HVACRFOU
Normal (non-emergency) lightingRFOU
Fire pump, emergency systemsBFOU (mandatory)
Escape route emergency lightingBFOU (mandatory)
Emergency generator outputBFOU (mandatory)

Contact TEBAOFLEX engineering for expert offshore cable selection and competitive pricing on both RFOU and BFOU cables.