Home » Industrial Flexible & Special Cable Products » BS 6708 Type 70 & Type 71 Pliable Wire Armoured Mining Cable | 320/550V Power & Lighting Cable

BS 6708 Type 70 & Type 71 Pliable Wire Armoured Mining Cable | 320/550V Power & Lighting Cable

BS 6708 Type 70 (4×4 mm²) and Type 71 (5×4 mm²) pliable wire armoured mining cables (320/550 V) engineered with IEC 60228 Class 5 tinned copper conductors, unscreened EPR-insulated cores, a 2.0 mm extruded rubber inner bedding, 7/0.45 mm galvanized steel pliable wire armour (PWA), and a 2.5 mm heavy-duty chloroprene (PCP) outer sheath for coalface lighting, crushing, and excavating equipment.

Standard & Models
BS 6708 — Type 70 (4×4) & Type 71 (5×4)
Rated / Test Voltage
320/550 V (AC Test: 1.5 kV)
Core Design
4 or 5 Unscreened EPR Cores (56/0.30 mm Class 5)
Mechanical Armouring
Galvanized Steel Pliable Wire Armour (7/0.45 mm)
Inner / Outer Sheaths
2.0 mm Rubber Bedding + 2.5 mm Black PCP Jacket
Ampacity & Armour Res.
28 A @ 25 °C | Armour DC Res.: 4.63–5.07 Ω/km
Engineering Datasheet: BS 6708 Type 70 & Type 71 Datasheet (PDF, 2 Pages)

Application & Operating Conditions

BS 6708 Type 70 and Type 71 are 320/550 V pliable wire armoured (PWA) flexible cables used for coalface roadway lighting strings, auxiliary crushing and excavating plant, and semi-mobile stage-loader substations in deep mines where explosive gases and coal dust accumulate, as well as heavy-duty surface quarries.

Coalface & Roadway Lighting Systems

Widely specified as the backbone interconnecting feeder between flameproof lighting transformers and armoured roadway luminaire fittings along advancing or retreating longwall gates.

Pliable Steel Strand Armour (7/0.45 mm)

Unlike rigid single-wire SWA cables, BS 6708 pliable armour uses stranded 7×0.45 mm galvanized steel wire bundles—combining rockfall crush protection with 234–247 mm bending flexibility.

High-Conductance Earth Armour Path

The helical galvanized steel pliable armour maintains a low maximum DC resistance of 5.07 Ω/km (Type 70) and 4.63 Ω/km (Type 71), matching the 5.09 Ω/km phase conductor resistance.

Type 70 vs Type 71 Quick Choice: Specify Type 70 (4×4 mm²) for 3-phase + earth or 3-phase lighting circuits using the pliable armour plus fourth core, and Type 71 (5×4 mm²) when an additional pilot-interlock, switched lighting phase, or dedicated neutral conductor is required.

Cable Construction (BS 6708 Type 70 & Type 71 Pliable Armour)

Built to BS 6708 with four (Type 70) or five (Type 71) unscreened 4 mm² EPR cores enclosed inside a dual-sheath rubber/PCP envelope reinforced by stranded galvanized steel pliable wire armour.

Layer / ComponentMaterial & BS 6708 Engineering Specification
1. ConductorsElectrolytic flexible stranded tinned copper wire, IEC 60228 Class 5 (56/0.30 mm stranding, 2.60 mm diameter, 4 mm² nominal cross-section).
2. Core InsulationExtruded Ethylene Propylene Rubber (EPR) insulation, 1.0 mm nominal radial thickness.
3. Core Lay-UpFour unscreened cores (Type 70) or five unscreened cores (Type 71) laid up in contact with each other in a compact circular assembly.
4. Inner Sheath / BeddingExtruded rubber-based inner bedding compound, 2.0 mm radial thickness (15.8–17.8 mm diameter on Type 70; 17.2–19.2 mm on Type 71).
5. Pliable Wire Armour (PWA)Helical layer of galvanized steel pliable wire strands (7/0.45 mm strand construction) applied between the inner and outer sheaths.
6. Outer SheathHeavy-duty black chloroprene (PCP) outer sheath, 2.5 mm nominal radial thickness, resistant to mine water, oils, rock impact, and flame spread.
Cross-section diagram of TEBAOFLEX BS 6708 Type 70 & Type 71 320/550V Pliable Wire Armoured Mining Cable

BS 6708 Type 70 / 71 Cross-Section: Unscreened Class 5 tinned copper EPR cores cushioned in 2.0 mm rubber inner bedding, armoured with 7/0.45 mm galvanized steel pliable wire strands, and oversheathed in 2.5 mm black PCP.

7/0.45 mm Galvanized Pliable Steel Armour Heavy-Duty Chloroprene (PCP) Sheath

Technical Characteristics

Dimensional, mechanical, and electrical characteristics compliant with British Standard BS 6708 Type 70 and Type 71.

ParameterBS 6708 Rated Value
Reference StandardBS 6708 (Pliable Wire Armoured Mining Power & Coalface Lighting Cables)
Rated Voltage (Uo/U)320 / 550 V AC
Routine AC Test Voltage1.5 kV AC
Model BreakdownType 70: 4×4 mm² Unscreened + PWA | Type 71: 5×4 mm² Unscreened + PWA
Armour Wire Construction7/0.45 mm Galvanized Steel Pliable Wire Strands
Minimum Bending Radius234 mm (Type 70) / 247 mm (Type 71)
Max. Pulling Tension96 kgf (Type 70) / 100 kgf (Type 71)
Continuous Current & DC Resistance28 A (@ 25 °C) | Phase Cond.: 5.09 Ω/km | Armour: 5.07 Ω/km (T70) / 4.63 Ω/km (T71)

BS 6708 Type 70 & Type 71 Complete Specification Tables

Full dimensional, armour, mechanical, current, and resistance specifications for BS 6708 Type 70 (4×4 mm²) and Type 71 (5×4 mm²).

1. Core, Inner Sheath, Pliable Armour & Overall Dimensions
BS 6708 TypeNominal Size (mm²)Stranding (No./mm)Cond. Dia. (mm)Insul. Thick. (mm)Inner Sheath (mm)Inner Sheath Dia. (mm)Armour Size (No./mm)Outer Sheath (mm)Min. OD (mm)Max. OD (mm)
Type 704×456/0.302.601.02.015.8 – 17.87/0.452.523.526.0
Type 715×456/0.302.601.02.017.2 – 19.27/0.452.524.927.4
2. Mechanical Ratings, Current Capacity & DC Resistance
BS 6708 TypeNominal Size (mm²)Min. Bend Radius (mm)Max. Pulling Tension (kgf)Approx. Weight (kg/km)Copper Weight (kg/km)Current @ 25 °C (A)Phase Cond. DC Res. (Ω/km)Armour DC Res. (Ω/km)
Type 704×4234961100154285.095.07
Type 715×42471001230192285.094.63

Selection Guide: BS 6708 Auxiliary, Lighting & Control Cables

Compare BS 6708 Type 70 & Type 71 against multi-core armoured control cables (Types 506–524) and other BS 6708 underground cables.

BS 6708 ModelCore & Pilot Architecture, Earth Design & Primary Duty
BS 6708 Type FS4 (640/1100V Flat)BS 6708 Type FS4 (640/1100V Flat): Flat parallel 4-core geometry (4×2.5 & 4×4 mm²) with tinned copper braided screens on all phase and pilot cores for monorail festoon and overhead catenary loops (100–120 mm bend radius).
BS 6708 Type 44 (125/72V Screened Drill)BS 6708 Type 44 (125/72V Screened Drill): 5×6 mm² handheld drilling machine cable with composite copper/nylon braided screens on 3 phase cores + unscreened pilot & earth cores around an elastomeric cradle.
BS 6708 Type 43 (125/72V Conducting Rubber Drill)BS 6708 Type 43 (125/72V Conducting Rubber Drill): 5×6 mm² metal-braid-free drilling cable with cores separated around a semiconducting elastomeric cradle and 1.5 mm conducting rubber inner sheath for non-fraying flex fatigue resistance.
BS 6708 Type 70 & Type 71 (320/550V Armoured) (This Product)4-core (Type 70, 4×4 mm²) and 5-core (Type 71, 5×4 mm²) unscreened EPR power & coalface lighting cables protected by 7/0.45 mm galvanized steel pliable wire armour.
BS 6708 Type 506 / 512 / 518 / 524 (320/550V Control)BS 6708 Type 506 / 512 / 518 / 524 (320/550V Control): 6-, 12-, 18-core (1.34 mm²) and 24-core (0.93 mm²) individually composite-screened & pliable wire armoured control cables for inter-segment mining machine telemetry and pilot interlocks.
BS 6708 Type 7 (640/1100V Trailing)BS 6708 Type 7 (640/1100V Trailing): Primary 640/1100 V unarmoured coalcutter trailing feeder (16–150 mm²) with 3 composite-screened phase cores, 1 unscreened pilot core, and central bare earth.

Frequently Asked Questions (FAQ)

Answers to common engineering questions on BS 6708 pliable wire armour (PWA) vs standard SWA and voltage upgrades.

How does BS 6708 pliable wire armour (7/0.45 mm) differ from standard BS 5467 SWA?

Standard BS 5467 SWA cables use solid single galvanized steel wires over rigid XLPE/PVC bedding for fixed installation only. BS 6708 Type 70 and Type 71 use 7-wire stranded 0.45 mm galvanized steel bundles over flexible EPR/rubber bedding, allowing repeated relocation as coalface lighting and crushing equipment advance with the face.

What if our circuit requires 640/1100 V or individually screened 4 mm² armoured cores?

BS 6708 Type 70 and Type 71 are unscreened cables rated at 320/550 V. For 640/1100 V pliable wire armoured circuits, specify BS 6708 Type 20/21 (unscreened, 2.5–150 mm²) or BS 6708 Type 62/63/64 (individually composite-screened 4 mm² pliable wire armoured cables).

Does the galvanized pliable armour meet earth-fault conductance requirements?

Yes. The 7/0.45 mm galvanized steel pliable armour provides a maximum DC resistance at 20 °C of 5.07 Ω/km on Type 70 and 4.63 Ω/km on Type 71—equal to or lower than the 5.09 Ω/km resistance of the 4 mm² tinned copper phase conductors.

Request a Quote for BS 6708 Type 70 or Type 71 Cable

Specify Type 70 (4×4 mm²) or Type 71 (5×4 mm²), required drum lengths, and destination port for a rapid factory quotation.

Explore All Mining & Tunneling Cables
Standard

BS 6708

Cable Type

Type 70 (4-Core) & Type 71 (5-Core) Pliable Wire Armoured Cable

Voltage Rating

320/550V (Test Voltage 1.5kV)

Cross-Section

4×4 mm² (Type 70), 5×4 mm² (Type 71)

Conductor Material

Flexible Stranded Tinned Copper (IEC 60228 Class 5, 56/0.30 mm)

Armour Construction

Galvanized Steel Pliable Wire Armour (7/0.45 mm)

Sheath Material

Rubber Inner Bedding + Heavy Duty Chloroprene (PCP) Outer Sheath

Application

Coalface Lighting, Underground Crushing & Excavating Equipment