Home » Industrial Flexible & Special Cable Products » 50V Underground Longwall Mining Signal Cable | 2–9 Core (18–10 AWG) Extra-Tough TPU Signal Cable

50V Underground Longwall Mining Signal Cable | 2–9 Core (18–10 AWG) Extra-Tough TPU Signal Cable

50 V Underground Longwall Mining Signal Cable delivers crush- and cut-resistant low-voltage roof-shield electrohydraulic control, pull-cord emergency stop, and face communication circuits—built with extra-flexible ASTM B-174 copper conductors (2 to 9 cores in 18, 16, 14, 12 & 10 AWG), +90°C non-chlorinated cross-linked FR polyolefin insulation, and an extra-tough TPU outer jacket.

Rated Voltage & Temp
50 V Underground Signal & Control | +90°C Continuous
Core Count & Gauges
2 to 9 Conductors across 18, 16, 14, 12 & 10 AWG (40 Sizes)
Conductor Stranding
Extra-Flexible Bunch-Stranded Copper per ASTM B-174
Core Insulation
Chemically Cross-Linked Non-Chlorinated FR Polyolefin
Outer Jacket
Extra-Tough TPU (Black Standard; Safety Orange Optional)
Shielding Option
Unshielded Standard | 100% Full Copper Braid on Request
Engineering Datasheet: All 40 sizes (18, 16, 14, 12 & 10 AWG, 2C–9C) dual-unit OD & weight

SKU: LONGWALL-SIGNAL-50V Category:

Application & Operating Conditions

50 V Underground Longwall Mining Signal Cable is designed for intrinsically safe and low-voltage control, telemetry, methane/airflow monitoring, electrohydraulic roof-support shield interconnects, conveyor pull-cord lockout switches, and voice/audio paging lines along underground longwall faces and gate roads. Chemically cross-linked, non-chlorinated flame-retardant polyolefin core insulation prevents conductor pinch-through under falling coal/rock, while the extra-tough thermoplastic polyurethane (TPU) jacket outlasts conventional PVC or rubber control cables by 3× to 5× in abrasive pan-line service.

Longwall Roof-Support & E-Stop Lines

Connects shield controller pods, solenoid valves, conveyor pull-key lockout switches, and face communication boxes across dynamic advancing longwall panels.

XL-FR Polyolefin + Extra-Tough TPU

Thermosetting non-chlorinated cross-linked polyolefin resists soldering/crush deformation, paired with high-tear-strength TPU in black or high-visibility safety orange.

Optional Full Copper Braid Shielding

Available with a full-coverage flexible copper wire braid beneath the TPU jacket for EMI immunity alongside high-horsepower shearer and VFD power cables.

Need 110 V Permissible Underground Mine Lighting Circuits? For 110 V AC/DC longwall face luminaires and drift lighting strings, select our companion 110V Underground Mine Lighting Cable (2–9C TPU).

Cable Construction (50 V Multi-Core XL-Polyolefin / Extra-Tough TPU)

Compact round multi-conductor signal architecture engineered for relentless flexing, pinch impact, and moisture exposure in underground coal and hard-rock mines.

Layer / ComponentMaterial & ASTM B-174 / Underground Mining TPU Engineering Specification
1. Signal Conductors (2–9×)Extra-flexible bunch-stranded annealed copper conductors manufactured to ASTM B-174 in 18 AWG, 16 AWG, 14 AWG, 12 AWG, and 10 AWG.
2. XL-FR Polyolefin InsulationChemically cross-linked, non-chlorinated thermosetting flame-retardant polyolefin (+90°C rated) offering high cut-through resistance and crisp color coding.
3. Round Cabled Core & Wrap2 to 9 insulated conductors concentrically cabled into a round profile with non-wicking fillers (where required) and a smooth core separator binder tape.
4. Optional Copper Braid ShieldFull flexible copper wire braid shield available upon request for high-EMI longwall pan-line troughs and shearer proximity zones.
5. Extra-Tough TPU Outer JacketAbrasion-, tear-, oil-, and water-resistant Thermoplastic Polyurethane (TPU) jacket in standard Black or high-visibility Safety Orange (±5% OD tolerance).
50V underground longwall mining signal cable cross-section showing multi-core XL-FR polyolefin conductors inside extra-tough TPU sheath

50V Longwall Signal Cable cross-section (7-conductor example): ASTM B-174 flexible copper cores, cross-linked FR polyolefin insulation, binder wrap (optional full Cu braid), and extra-tough TPU sheath.

Extra-Tough Orange / Black TPU XL-FR Non-Chlorinated Polyolefin

Technical Characteristics

Electrical, thermal, dimensional tolerance, and material parameters for 50 V Longwall Mining Signal Cable.

ParameterASTM B-174 / Underground Mining TPU Rated Value
Rated Voltage50 V AC / DC underground mining signal, telemetry, and control circuits
Conductor Counts & Sizes2, 3, 4, 5, 6, 7, 8, or 9 conductors across 18 AWG, 16 AWG, 14 AWG, 12 AWG, and 10 AWG
Temperature Rating+90°C maximum continuous conductor operating temperature
Conductor StandardASTM B-174 extra-flexible bunch-stranded copper
Shielding & Jacket OptionsUnshielded standard or full copper braid on request | Black TPU standard; Orange TPU optional
Outside Diameter Tolerance±5% of nominal overall cable diameter

50 V Longwall Signal Cable Dimensions & Weights (18 AWG to 10 AWG, 2–9 Cores)

Complete 40-size engineering matrix covering 18, 16, 14, 12, and 10 AWG in 2-conductor through 9-conductor builds (dual imperial and metric units).

Table 1: 18 AWG (0.82 mm²) & 16 AWG (1.31 mm²) — 50 V Longwall Signal Cable (2 to 9 Conductors)
ConstructionCore Area (mm²)ConductorsInsulated Core OD (in / mm)Nominal Cable OD (in / mm)Approx. Weight (lb/kft / kg/km)
2 × 18 AWG0.8220.115 / 2.90.440 / 11.287 / 129
3 × 18 AWG0.8230.115 / 2.90.460 / 11.7100 / 149
4 × 18 AWG0.8240.115 / 2.90.490 / 12.4117 / 174
5 × 18 AWG0.8250.115 / 2.90.520 / 13.2136 / 202
6 × 18 AWG0.8260.115 / 2.90.560 / 14.2156 / 232
7 × 18 AWG0.8270.115 / 2.90.560 / 14.2163 / 243
8 × 18 AWG0.8280.115 / 2.90.630 / 16.0197 / 293
9 × 18 AWG0.8290.115 / 2.90.660 / 16.8215 / 320
2 × 16 AWG1.3120.125 / 3.20.460 / 11.799 / 147
3 × 16 AWG1.3130.125 / 3.20.480 / 12.2114 / 170
4 × 16 AWG1.3140.125 / 3.20.510 / 13.0133 / 198
5 × 16 AWG1.3150.125 / 3.20.550 / 14.0158 / 235
6 × 16 AWG1.3160.125 / 3.20.590 / 15.0183 / 272
7 × 16 AWG1.3170.125 / 3.20.590 / 15.0190 / 283
8 × 16 AWG1.3180.125 / 3.20.660 / 16.8225 / 335
9 × 16 AWG1.3190.125 / 3.20.690 / 17.5247 / 368
Table 2: 14 AWG (2.08 mm²) & 12 AWG (3.31 mm²) — 50 V Longwall Signal Cable (2 to 9 Conductors)
ConstructionCore Area (mm²)ConductorsInsulated Core OD (in / mm)Nominal Cable OD (in / mm)Approx. Weight (lb/kft / kg/km)
2 × 14 AWG2.0820.140 / 3.60.490 / 12.4118 / 176
3 × 14 AWG2.0830.140 / 3.60.510 / 13.0138 / 205
4 × 14 AWG2.0840.140 / 3.60.550 / 14.0166 / 247
5 × 14 AWG2.0850.140 / 3.60.590 / 15.0196 / 292
6 × 14 AWG2.0860.140 / 3.60.630 / 16.0225 / 335
7 × 14 AWG2.0870.140 / 3.60.630 / 16.0238 / 354
8 × 14 AWG2.0880.140 / 3.60.710 / 18.0278 / 414
9 × 14 AWG2.0890.140 / 3.60.750 / 19.0300 / 446
2 × 12 AWG3.3120.160 / 4.10.526 / 13.4148 / 220
3 × 12 AWG3.3130.160 / 4.10.555 / 14.1177 / 263
4 × 12 AWG3.3140.160 / 4.10.596 / 15.1213 / 317
5 × 12 AWG3.3150.160 / 4.10.642 / 16.3254 / 378
6 × 12 AWG3.3160.160 / 4.10.690 / 17.5297 / 442
7 × 12 AWG3.3170.160 / 4.10.690 / 17.5316 / 470
8 × 12 AWG3.3180.160 / 4.10.770 / 19.6388 / 577
9 × 12 AWG3.3190.160 / 4.10.815 / 20.7426 / 634
Table 3: 10 AWG (5.26 mm²) Heavy Valve & Solenoid Bus Series — 50 V Longwall Signal Cable (2 to 9 Conductors)
ConstructionCore Area (mm²)ConductorsInsulated Core OD (in / mm)Nominal Cable OD (in / mm)Approx. Weight (lb/kft / kg/km)
2 × 10 AWG5.2620.180 / 4.60.570 / 14.5186 / 277
3 × 10 AWG5.2630.180 / 4.60.598 / 15.2226 / 336
4 × 10 AWG5.2640.180 / 4.60.645 / 16.4276 / 411
5 × 10 AWG5.2650.180 / 4.60.696 / 17.7331 / 493
6 × 10 AWG5.2660.180 / 4.60.750 / 19.0391 / 582
7 × 10 AWG5.2670.180 / 4.60.750 / 19.0462 / 688
8 × 10 AWG5.2680.180 / 4.60.835 / 21.2519 / 772
9 × 10 AWG5.2690.180 / 4.60.875 / 22.2626 / 932
Dimensional & Braid Note: Listed outside diameters and weights apply to unshielded TPU builds (±5% OD tolerance; 1 lb/ft = 1,000 lb/kft = 1,488.16 kg/km). When ordered with optional full copper braid shielding, nominal OD increases by approximately 0.030–0.050 in (0.8–1.3 mm).

Underground Signal, Lighting, VFD & Control Cable Matrix

Select between 50 V Longwall Signal, 110 V Underground Lighting, 2 kV Symmetrical VFD, and composite power-control cables.

Mining Cable ModelVoltage Class, Ground / Shield Architecture & Primary Mining Duty
Mining VFD 2kV (3+3+GC)Symmetrical 3 power + 3 green grounds + yellow GC (2 AWG–500 kcmil) with 100% Al/polyester foil + overall tinned copper braid EMC shield for AC variable-frequency mine drives.
Blast-Hole Drilling Mast (600–2000V)High-flex round hybrid cable combining 2 EPR power cores (1/0–500 kcmil) + tinned ground + user-configurable multi-core control group for rotary drill masts, festoons, and loops.
Longwall Signal Cable (50V TPU)Extra-flexible 50 V underground control & signal cable (2–9 cores, 18 to 10 AWG) with cross-linked FR polyolefin insulation, extra-tough TPU jacket, and optional copper braid.
Underground Lighting Cable (110V TPU)Heavy-duty 110 V mine luminaire & drift lighting cable (2–9 cores, 18 to 10 AWG) with non-chlorinated cross-linked FR polyolefin insulation and cut-resistant TPU outer sheath.
Type SHD-PCG (2kV & 5kV)Shielded 3-phase power + 2 integrated control/pilot cores + ground trailing cable for continuous miners and longwall face equipment.

Frequently Asked Questions (FAQ)

Answers to longwall electrical questions on non-chlorinated cross-linked polyolefin insulation, orange vs. black TPU, and braided EMI shielding.

Why does TEBAOFLEX use chemically cross-linked non-chlorinated FR polyolefin instead of PVC on the signal cores?

Cross-linked thermosetting polyolefin will not melt or cold-flow when pinched under roof-shield hydraulic hoses or hot overloads (+90°C continuous rating), and its non-chlorinated formulation reduces corrosive acid gas release in confined underground workings.

When should we choose 14–10 AWG versus 18–16 AWG in a 50V longwall signal cable?

18 AWG and 16 AWG are ideal for short shield-to-shield jumper harnesses, pull-cord switches, and digital RS-485/CAN telemetry; 14 AWG, 12 AWG, and 10 AWG minimize DC voltage drop across 250 m to 450 m full-face solenoid power buses and paging trunk lines.

Can we order high-visibility safety orange TPU with MSHA-compliant flame resistance?

Yes. Both standard Black TPU and high-visibility Safety Orange TPU outer jackets are compounded with flame-retardant mining-grade polyurethane elastomers and can be custom-printed with sequential footage markers.

Request a 50V Longwall Mining Signal Cable Quote

Specify conductor gauge (18, 16, 14, 12, or 10 AWG), core count (2 to 9 conductors), black or orange TPU jacket, and unshielded or copper-braided option.

Explore All Mining & Tunneling Cables
Voltage Rating

50 V Underground Mining Signal & Control

Conductor Range

2 to 9 Conductors in 18, 16, 14, 12 & 10 AWG (40 Sizes)

Conductor Material

Extra-Flexible Bunch-Stranded Copper per ASTM B-174

Insulation Material

+90°C Cross-Linked Non-Chlorinated Flame-Retardant Polyolefin

Sheath Material

Extra-Tough TPU (Black Standard; Safety Orange Optional)

Shielding Option

Unshielded Standard or Full Copper Braid Shield on Request