Home » Industrial Flexible & Special Cable Products » 2000V Symmetrical 3+3+GC Mining VFD Power Cable | Foil + Copper Braid Shielded EPDM/CPE Drive Cable

2000V Symmetrical 3+3+GC Mining VFD Power Cable | Foil + Copper Braid Shielded EPDM/CPE Drive Cable

2000 V Symmetrical 3+3+GC Mining VFD Power Cable eliminates variable-frequency PWM common-mode shaft currents and high-frequency EMI in surface and underground mine AC drives—combining three rope-lay tinned copper 90°C Type II EPDM phases, three symmetrical green-insulated grounds, a yellow ground-check core, and a 100% aluminum/polyester foil + overall tinned copper braid shield.

Rated Voltage
2,000 V AC PWM Variable-Frequency Drive (VFD) Duty
Symmetrical Topology
3 Power Cores + 3 Green Symmetrical Grounds + 1 Yellow GC
Conductor Size Range
2 AWG (33.62 mm²) through 500 kcmil (253.4 mm²)
VFD Dielectric
90°C Corona- & Ozone-Resistant Type II EPDM (EPR)
Dual EMC Shielding
100% Al/Polyester Tape + Overall Tinned Copper Braid
Jacket & Standards
Mold-Cured Black CPE | ICEA S-75-381 & CSA C22.2 No.96
Engineering Datasheet: Full 2 AWG–500 kcmil 3+3+GC OD, weight & reel derating tables

SKU: MINING-VFD-2KV-3C3GGC Category:

Application & Operating Conditions

2000 V Symmetrical 3+3+GC Mining VFD Power Cable is purpose-engineered for variable-frequency AC motor drives on underground longwall shearers, armored face conveyors, continuous haulage systems, mine hoist/slurry pump skids, and surface excavator/crusher VFDs. Splitting the equipment ground into three equal green-insulated conductors arranged at 120-degree intervals inside a 100% foil-plus-copper-braid shield balances phase-to-ground capacitance, suppresses reflected voltage spikes, and diverts destructive bearing currents away from mine motor shafts while maintaining continuous MSHA ground-check loop monitoring.

Balanced 3+3 Low-Impedance Ground Return

Three symmetrically phased green-insulated tinned copper grounds cancel electromagnetic field imbalance and provide a low-inductance return path for high-dV/dt IGBT switching currents.

100% Foil + Tinned Braid EMC Containment

Combination aluminum/polyester tape (high-frequency MHz containment) and heavy tinned copper braid (low-frequency kHz drain & mechanical flex durability) prevents PLC and gas-sensor interference.

Monitored Ground-Check (Center or Interstice)

Includes a yellow-insulated flexible tinned copper ground-check conductor (14 AWG minimum in interstice, or neutral-axis center GC configuration) compatible with standard mine ground-fault relays.

Why Standard Asymmetric Type SHD-GC Can Trip VFD Drives: Conventional two-ground trailing cables have unequal phase-to-ground capacitance across the three phases, driving zero-sequence common-mode currents into motor bearings. Use Symmetrical 3+3+GC VFD Cable between IGBT inverter cabinets and AC mine motors.

Cable Construction (2000 V Symmetrical 3+3+GC Braid + Foil Shielded)

Engineered to ICEA S-75-381 / NEMA WC 58 and CSA C22.2 No. 96 for rugged portable and mobile VFD mining installations.

Layer / ComponentMaterial & ICEA S-75-381 / CSA C22.2 No. 96 Engineering Specification
1. Power Conductors (3×)Three extra-flexible rope-lay stranded annealed tinned copper conductors (2 AWG to 500 kcmil) per ASTM B172 and ASTM B33.
2. 90°C Type II EPDM InsulationHigh-dielectric-strength, ozone- and corona-resistant Type II EPDM (EPR) rubber rated +90°C continuous to withstand repetitive PWM inverter voltage reflections.
3. Symmetrical Grounds (3×)Three flexible rope-lay stranded tinned copper grounding conductors (8 AWG to 1/0 AWG), insulated and colored Green, placed symmetrically at 120° intervals.
4. Ground-Check Conductor (GC)Flexible stranded tinned copper pilot conductor with yellow insulation (available as neutral-axis center ground-check or interstitial ≥14 AWG pilot).
5. 100% Foil + Cu Braid ShieldOverall 100%-coverage aluminum/polyester metallic tape combined with a high-coverage flexible tinned copper wire braid shield.
6. Mold-Cured Black CPE JacketReinforced extra-heavy-duty mold-cured thermosetting Chlorinated Polyethylene (CPE) outer sheath (155 mil to 265 mil wall; ±5% OD tolerance).
2000V symmetrical 3+3+GC mining VFD cable cross-section showing 3 power cores, 3 symmetrical grounds, center GC, foil and tinned copper braid shield

2000V 3+3+GC VFD cross-section: 3 Type II EPDM power cores, 3 symmetrical green-insulated grounds, yellow GC pilot, 100% Al/polyester foil + tinned copper braid, and mold-cured CPE jacket.

100% Foil + Tinned Cu Braid EMC Shield Symmetrical 3 Power + 3 Ground + GC

Technical Characteristics

Electrical, thermal, shielding, and reel-layer correction parameters for 2,000 V Mining VFD Power Cable.

ParameterICEA S-75-381 / CSA C22.2 No. 96 Rated Value
Rated Voltage2,000 V AC continuous (engineered for PWM variable-frequency AC drives up to 2 kV class)
Conductor ArchitectureRound symmetrical: 3 power + 3 green insulated grounds + 1 yellow ground-check
Overall EMC Shielding100% coverage aluminum/polyester tape + overall tinned copper wire braid
Temperature Rating+90°C maximum continuous conductor temperature | +40°C base ampacity ambient
Manufacturing OD Tolerance±5% of nominal overall cable outside diameter
Standards ReferenceICEA S-75-381 / NEMA WC 58; ASTM B172 & ASTM B33; CAN/CSA-C22.2 No. 96

2000 V Symmetrical 3+3+GC Mining VFD Dimensions & Ampacity (2 AWG to 500 kcmil)

Complete dual-unit nominal dimensions, symmetrical three-ground gauges, jacket wall thicknesses, weights, and +90°C continuous ampacity ratings.

Table 1: 2000 V Symmetrical 3 Power + 3 Ground + Ground-Check VFD Cable — Foil + Braid Shielded CPE
Power CoresArea (mm²)Symmetrical GroundsGC CoreEMC ShieldJacket Wall (in / mm)Nominal OD (in / mm)Weight (lb/kft / kg/km)Ampacity 40°C (A)
3 × 2 AWG33.623 × 8 AWGYellow GCBraid + Foil0.155 / 3.91.43 / 36.31,790 / 2,664159
3 × 1 AWG42.413 × 7 AWGYellow GCBraid + Foil0.170 / 4.31.64 / 41.72,150 / 3,199184
3 × 1/0 AWG53.493 × 6 AWGYellow GCBraid + Foil0.170 / 4.31.74 / 44.22,550 / 3,795211
3 × 2/0 AWG67.433 × 5 AWGYellow GCBraid + Foil0.190 / 4.81.89 / 48.03,100 / 4,613243
3 × 3/0 AWG85.013 × 4 AWGYellow GCBraid + Foil0.190 / 4.82.01 / 51.14,050 / 6,027279
3 × 4/0 AWG107.23 × 3 AWGYellow GCBraid + Foil0.220 / 5.62.17 / 55.14,390 / 6,533321
3 × 250 kcmil126.73 × 3 AWGYellow GCBraid + Foil0.220 / 5.62.40 / 61.05,950 / 8,855355
3 × 350 kcmil177.33 × 1 AWGYellow GCBraid + Foil0.235 / 6.02.68 / 68.17,840 / 11,667435
3 × 500 kcmil253.43 × 1/0 AWGYellow GCBraid + Foil0.265 / 6.73.03 / 77.09,730 / 14,480536
Reel Layer Correction Factors: Base ampacities apply at +90°C conductor temperature in +40°C free air. When wound on mobile reels, multiply ampacity by 0.85 (1 layer), 0.65 (2 layers), 0.45 (3 layers), or 0.35 (4 layers). Center ground-check and custom colored CPE/TPU jackets are available upon request.

Specialty Mining VFD, Drill Mast, Signal & Lighting Selection

Compare 2000 V Symmetrical VFD Cable against Drilling Mast, Longwall Signal, Underground Lighting, and Type SHD-PCG cables.

Mining Cable ModelVoltage Class, Ground / Shield Architecture & Primary Mining Duty
Mining VFD 2kV (3+3+GC)Symmetrical 3 power + 3 green grounds + yellow GC (2 AWG–500 kcmil) with 100% Al/polyester foil + overall tinned copper braid EMC shield for AC variable-frequency mine drives.
Blast-Hole Drilling Mast (600–2000V)High-flex round hybrid cable combining 2 EPR power cores (1/0–500 kcmil) + tinned ground + user-configurable multi-core control group for rotary drill masts, festoons, and loops.
Longwall Signal Cable (50V TPU)Extra-flexible 50 V underground control & signal cable (2–9 cores, 18 to 10 AWG) with cross-linked FR polyolefin insulation, extra-tough TPU jacket, and optional copper braid.
Underground Lighting Cable (110V TPU)Heavy-duty 110 V mine luminaire & drift lighting cable (2–9 cores, 18 to 10 AWG) with non-chlorinated cross-linked FR polyolefin insulation and cut-resistant TPU outer sheath.
Type SHD-PCG (2kV & 5kV)Shielded 3-phase power + 2 integrated control/pilot cores + ground trailing cable for continuous miners and longwall face equipment.

Frequently Asked Questions (FAQ)

Engineering FAQs on 3+3+GC VFD grounding termination, corona resistance, and ground-check placement.

How should the overall foil/braid shield and three green ground wires be terminated at VFD cabinets and motors?

Terminate the overall tinned copper braid 360 degrees at both the inverter enclosure and motor terminal box using EMC compression glands, and bond all three symmetrical green ground conductors equally onto the ground bus at both ends to preserve balanced low-impedance high-frequency return.

Why is Type II EPDM rubber preferred over PVC/nylon (THHN) in 2000V mining VFD cables?

Type II EPDM (EPR) exhibits a low dielectric constant (~2.8–3.2 vs. 6–8 for PVC) and superior corona/partial-discharge inception voltage, dramatically cutting capacitive charging spikes on long motor feeder runs while retaining full cold-weather flexibility.

Can this 2000V VFD cable be built with a neutral-axis Center Ground-Check (CGC)?

Yes. We supply both center-positioned yellow ground-check builds (ideal for dynamic cable-handler chains and reels) and interstitial ground-check builds (14 AWG minimum) to match your mine coupler pinout.

Request a 2000V Symmetrical 3+3+GC Mining VFD Cable Quote

Specify power conductor size (2 AWG to 500 kcmil), center or interstitial ground-check preference, and required drum cut lengths for factory pricing.

Explore All Mining & Tunneling Cables
Voltage Rating

2000 V AC (Variable-Frequency Drive Rated)

Core Configuration

Symmetrical 3 Power + 3 Green Grounds + 1 Yellow Ground-Check

Shielding

100% Aluminum/Polyester Foil Tape + Overall Tinned Copper Braid

Conductor Material

Extra-Flexible Rope-Lay Stranded Tinned Copper (2 AWG – 500 kcmil)

Insulation & Jacket

90°C Type II EPDM (EPR) + Reinforced Mold-Cured Black CPE

Standard

ICEA S-75-381 / NEMA WC 58, ASTM B172/B33, CSA C22.2 No. 96