UL 10362 PFA 250°C 600V High Temperature Wire is a single-core hook-up wire for protected internal wiring in appliances and electronic equipment. It combines PFA insulation with tinned, nickel-plated or silver-plated copper conductor options. The documented product family is rated 600 V and 250°C and covers conductor sizes from 8 AWG to 30 AWG.
This PFA insulated wire is intended for engineers and buyers selecting compact, high-temperature equipment wire where conductor plating, finished diameter and insulation colour must be matched to the installation. TEBAOFLEX can confirm the final conductor construction, colour, length and packaging after reviewing the application.
What is UL 10362 wire?
UL 10362 wire is a 600 V, 250°C single-conductor PFA wire used for internal equipment connections. PFA is a fluoropolymer insulation material selected for high-temperature electrical insulation, a smooth surface and resistance to demanding operating environments. The conductor may be tinned copper, nickel-plated copper or silver-plated copper, depending on the requested configuration.
Key product features
- Single-core PFA insulated high-temperature hook-up wire.
- Documented electrical rating of 600 V.
- Documented conductor temperature rating of 250°C.
- Tinned, nickel-plated or silver-plated copper conductor options.
- Documented conductor-size range from 8 AWG to 30 AWG.
- Multiple insulation colours and customised cut lengths available for confirmation.
UL 10362 technical specifications
| Parameter | Specification |
|---|---|
| Product model | UL 10362 |
| Product type | Single-core PFA insulated high-temperature wire |
| Rated voltage | 600 V |
| Rated temperature | 250°C |
| Conductor options | Tinned, nickel-plated or silver-plated copper |
| Insulation | PFA fluoropolymer |
| Documented size range | 8 AWG to 30 AWG |
| Typical installation | Protected internal appliance and electronic-equipment wiring |
AWG size and dimensional guide
The values below are documented reference constructions. Several AWG sizes have alternative conductor builds; the final stranding, conductor diameter, insulation thickness and finished outside diameter must be confirmed for the ordered configuration.
| AWG | Example conductor (No./mm) | Nominal insulation | Finished outside diameter |
|---|---|---|---|
| 8 AWG | 133 / 0.287 mm | 0.76 mm | 5.34 ± 0.15 mm |
| 10 AWG | 37 / 0.42 mm | 0.30 mm | 3.54 ± 0.15 mm |
| 12 AWG | 37 / 0.374 mm | 0.30 mm | 3.22 ± 0.10 mm |
| 14 AWG | 19 / 0.361 mm | 0.30 mm | 2.45 ± 0.10 mm |
| 16 AWG | 19 / 0.287 mm | 0.25 mm | 2.00 ± 0.10 mm |
| 18 AWG | 19 / 0.235 mm | 0.25 mm | 1.67 ± 0.10 mm |
| 20 AWG | 19 / 0.19 mm | 0.25 mm | 1.46 ± 0.10 mm |
| 22 AWG | 19 / 0.15 mm | 0.25 mm | 1.25 ± 0.10 mm |
| 24 AWG | 7 / 0.20 mm | 0.25 mm | 1.10 ± 0.10 mm |
| 26 AWG | 7 / 0.16 mm | 0.25 mm | 0.98 ± 0.10 mm |
| 28 AWG | 7 / 0.127 mm | 0.25 mm | 0.88 ± 0.10 mm |
| 30 AWG | 7 / 0.10 mm | 0.25 mm | 0.80 ± 0.10 mm |
Typical applications
Typical uses include protected internal wiring for high-temperature appliances, electronic equipment, control assemblies, instruments and compact electrical devices. Product selection must account for the actual conductor temperature, voltage, current, routing, enclosure, bending and surrounding materials.
This single-core wire is not intended to replace a multi-core control cable, outdoor power cable, continuously flexing cable or wet-location cable unless a separately confirmed construction is specified for that duty.
How to specify the correct PFA wire
- Select the required conductor size from 8 AWG to 30 AWG.
- Choose tinned, nickel-plated or silver-plated copper according to the equipment design.
- State the insulation colour, required length and packaging preference.
- Provide operating temperature, voltage, routing and equipment details for confirmation.
Compare related options in the high-temperature and specialty cable range, including UL 1330 FEP high-temperature wire for applications requiring a different fluoropolymer construction.
Frequently asked questions
What temperature is UL 10362 PFA wire designed for?
The documented conductor temperature rating is 250°C. The complete assembly and installation environment still require confirmation.
What is the voltage rating?
The documented rated voltage is 600 V.
Which conductor plating should I choose?
Tinned, nickel-plated and silver-plated copper configurations are available for confirmation. Selection depends on temperature, termination method and equipment requirements.
What sizes are available?
The documented family covers 8 AWG through 30 AWG, with alternative conductor constructions available for several sizes.
Can insulation colour and packaging be customised?
Yes. State the required colour, length and packaging in the enquiry so TEBAOFLEX can confirm the production configuration.