(N)TSCGEWCUEUS 6/10 kV is a water-resistant medium-voltage flexible cable designed around a supplied 3 × 50 mm² phase-conductor configuration, two 25/2 mm² earth conductors and four 0.5 mm² auxiliary cores. It combines EPR-insulated power cores, semiconductive screens, an overall tinned-copper braid and PCP outer-sheath construction for defined wet-service, trailing and heavy-duty handling conditions.
The supplied configuration is intended for project power connections where electrical power, earthing and auxiliary monitoring or control circuits need to run together. Typical environments include dredgers, floating docks, pumps, pontoons, water-handling equipment and mining routes exposed to water, mud, vibration and mechanical handling. Final selection must consider the actual route, movement, water exposure, bend path and installation correction factors.
Product Overview
| Item | Supplied configuration |
|---|---|
| Product family | (N)TSCGEWCUEUS 6/10 kV screened medium-voltage flexible cable for use in water |
| Reference voltage | 6/10 kV AC (U0/U); maximum system voltage Um 12 kV |
| Core arrangement | 3 × 50 mm² phase cores + 2 × 25/2 mm² earth conductors + 4 × 0.5 mm² auxiliary cores |
| Conductor | Flexible, finely stranded tinned annealed copper; Class 5 reference |
| Insulation | EPR with semiconductive conductor and insulation screens |
| Overall screen | Tinned-copper wire braid over the assembled cable |
| Inner / outer sheath | GM1b inner sheath and 5GM5 PCP outer sheath |
| Identification | Cable designation and length marking |
Why This Configuration Is Used in Wet-Service Routes
For wet or submerged power service, the construction brings the phase conductors, earth conductors and auxiliary circuits into one screened flexible cable. EPR insulation provides the primary dielectric layer, while semiconductive layers support electric-field control around the medium-voltage cores. In addition, the tinned-copper braid provides a flexible low-impedance bonding and screening layer around the assembly.
The tinned-copper conductor construction is selected for corrosion resistance in fresh, brackish or salt-water-exposed routes. Meanwhile, the rubber-based inner and outer sheath system is specified for water exposure and heavy mechanical handling. The cable should still be selected against the actual installation conditions; sustained tension, reeling geometry, guide rollers, water pressure and grouped-cable heat conditions must be reviewed before approval.
Cable Construction

- Finely stranded tinned-copper phase conductors for flexible handling.
- Semiconductive conductor screen to smooth the electric field.
- EPR insulation as the main dielectric layer.
- Semiconductive insulation screen and tape wrap.
- Tinned-copper earth conductors with semiconductive rubber insulation.
- Four EPR-insulated auxiliary cores in a screened control group.
- GM1b inner sheath around the assembled cores.
- Overall tinned-copper wire braid for bonding and electromagnetic screening.
- 5GM5 PCP outer sheath for the specified mechanical and environmental protection.
Electrical, Thermal and Mechanical Data
| Parameter | Reference value | Selection note |
|---|---|---|
| AC test voltage | 17 kV AC for 5 min | Reference test value from the supplied configuration. |
| Current-carrying capacity | Approx. 200 A per phase at 30 °C in free air | Apply installation, grouping, water and temperature correction factors. |
| Phase-conductor resistance | Approx. 0.393 Ω/km at 20 °C for each 50 mm² phase conductor | Earth and auxiliary conductor values vary by size. |
| Operating temperature | -40 to +90 °C | Maximum continuous conductor temperature: 90 °C. |
| Short-circuit temperature | 250 °C maximum conductor temperature | Short-duration fault condition reference. |
| Minimum bend radius | 6 × overall cable diameter | Approx. 348 mm when calculated from the stated 58 mm maximum OD. |
| Finished outer diameter | 54-58 mm | Calculated nominal range from the supplied construction. |
| Copper index | Approx. 2,073.2 kg/km | Includes the overall braid in the supplied calculation. |
| Cable weight | Approx. 5,094.0 kg/km | Calculated nominal value; confirm final production tolerance. |
| Insulation resistance | Minimum 1,000 MΩ·km at 20 °C | EPR reference value. |
Environmental and Fire Behaviour
The supplied design data identifies a water-blocking GM1b inner sheath and a tough 5GM5 PCP outer sheath for wet, oil-exposed and mechanically demanding routes. It also references water, oil, ozone, ultraviolet-light, abrasion and tearing resistance for the selected sheath system. Where the project requires a specific test report, installation approval or third-party certificate, confirm the applicable scope before ordering.
| Design or test reference | Supplied data statement |
|---|---|
| Flame behaviour | Flame-retardant and self-extinguishing reference: IEC 60332-1-2. |
| Oil resistance | Reference: IEC 60811-404. |
| Ozone resistance | Reference: IEC 60811-403. |
| UV resistance | Reference: ISO 4892-2. |
| Halogen status | Not halogen-free; the outer sheath is polychloroprene based. |
| Applicable cable standards | Design references: DIN VDE 0250-813, IEC 60502-2 and IEC 60228 Class 5. |
Typical Applications
- Dredgers, floating docks and water-handling equipment requiring a flexible medium-voltage power connection.
- Pumps, pontoons and wet-service installations where a screened cable with integrated auxiliary circuits is required.
- Open-pit and underground mining routes exposed to water, mud, abrasion, vibration and mechanical stress.
- Heavy-duty trailing, free-hanging or fixed installations after review of movement and installation conditions.


Ordering and Installation Information
For a correct quotation, provide the required cable length, equipment type, route layout, expected movement, installation method, operating voltage, temperature, water exposure, drum or guide design and auxiliary-core requirement. The 200 A ampacity is a free-air reference at 30 °C and must be corrected for the final installation. TEBAOFLEX assigns the final order number, finished dimensions and production tolerances before purchase release.
FAQ
Can this cable be used in water or submerged power service?
The supplied configuration is intended for wet and submerged power-service applications such as dredgers, floating docks, pumps and pontoons. Confirm the actual water exposure, route and installation requirements before ordering.
What is the purpose of the four auxiliary cores?
The four 0.5 mm² EPR-insulated auxiliary cores are provided for monitoring, signalling or control functions alongside the medium-voltage phase conductors.
Is the stated 200 A ampacity the final design value?
No. It is a 30 °C free-air reference for the supplied configuration. Installation, grouping, water and temperature correction factors must be applied to the actual route.
Which standards apply to this cable?
The supplied design references DIN VDE 0250-813, IEC 60502-2 and IEC 60228 Class 5. Confirm the project-specific compliance or certificate requirement before purchase.
Request a Project-Specific Quote
Send the required length, application, installation route and environmental conditions so that the final construction can be confirmed.
Related TEBAOFLEX product categories: Submersible & Underwater Cables and Mining & Tunneling Cables.