4.70 mm Mono Conductor Wireline Cable

Armored 4.70 mm mono conductor wireline cable with a 20 AWG copper core and 12 inner / 15 outer armor wire construction.

The 4.70 mm Mono Conductor Wireline Cable is an armored electrical cable for downhole logging, intervention, and well-service applications. Its construction combines a stranded copper conductor, insulation, and two mechanical armor layers to carry an electrical signal while supporting controlled deployment in the well. TEBAOFLEX can review the required load, sheave diameter, temperature, fluid exposure, and length before configuration selection.

Key Features

  • Armored mono conductor construction for electrical continuity and mechanical support.
  • Specified voltage, resistance, and tensile data for the documented configuration.
  • Multiple insulation options where stated in the technical data, allowing selection by temperature requirement.
  • Suitable for controlled wireline deployment where the selected load and sheave arrangement remain within the documented limits.

Downhole Application

Armored mono conductor wireline cable deployed from a logging winch to an oil and gas wellhead
Armored mono conductor wireline cable deployed from a logging winch during an oil and gas well-service operation.

Wireline systems are used to lower and retrieve downhole tools while providing a reliable electrical path. Installation should follow the selected cable’s documented load limits, bend guidance, and environmental requirements.

Technical Parameters

ParameterSpecification
Center conductor20 AWG, 7 x 0.0128 in; 0.038 in / 0.965 mm nominal diameter
Insulation outside diameter0.084 in / 2.135 mm
Inner armor layer12 galvanized steel wires x 0.0240 in; 0.125 in / 3.175 mm layer OD
Outer armor layer15 galvanized steel wires x 0.0298 in; 0.185 in / 4.699 mm layer OD
Rated voltage1000 VDC
DC conductor resistance at 20 °C9.8 Ω/kft / 32.2 Ω/km
DC armor resistance at 20 °C6.4 Ω/kft / 21.0 Ω/km
Minimum insulation resistance1500 MΩ·kft / 457 MΩ·km
Breaking strength, fixed ends3,900 lb / approx. 1,769 kg
Maximum working load1,950 lb / approx. 885 kg
Suggested minimum sheave diameter12 in / 305 mm
Outside diameter tolerance+0.003 / -0.002 in; +0.102 / -0.051 mm
Stretch coefficient4.0 ft/kft/klb / 4.5 m/km/5 kN

Configuration and Insulation Options

Construction codeInsulationMaximum temperatureCapacitanceWeight in air / water
1-P-185-12/15-G-7Polypropylene300 °F / 149 °C46 pF/ft / 151 pF/m94 / 80 kg/km
1-T-185-12/15-G-7ETFE500 °F / 260 °C53 pF/ft / 174 pF/m97 / 83 kg/km
1-A-185-12/15-G-7PFA550 °F / 288 °C45 pF/ft / 146 pF/m98 / 83 kg/km
1-Q-185-12/15-G-7Q600600 °F / 315 °C45 pF/ft / 146 pF/m98 / 83 kg/km

Selection Guidance

Match the exact conductor, armor material, insulation system, working load, sheave diameter, temperature, and well environment to the project requirement. The listed values are configuration-specific; confirm the final construction before purchasing.

Request a Quote

Request a quote with the required length, operating conditions, load, temperature range, and target configuration.

Product Model

4.70 mm Mono Conductor Wireline Cable

Product Type

Mono conductor armored wireline cable

Conductor

20 AWG, 7 x 0.0128 in stranded copper

Insulation OD

2.135 mm

Inner Armor

12 wires x 0.0240 in

Outer Armor

15 wires x 0.0298 in

Overall Diameter

4.699 mm

Rated Voltage

1000 VDC

Suggested Minimum Sheave Diameter

305 mm

Temperature Rating

149 °C to 315 °C, by insulation type