Home » Industrial Flexible & Special Cable Products » SANS 1520-2 Type 63 Medium Voltage Trailing Cable | 1.9/3.3kV Reeling Mining Cable

SANS 1520-2 Type 63 Medium Voltage Trailing Cable | 1.9/3.3kV Reeling Mining Cable

SANS 1520-2 Type 63 medium-voltage flexible trailing and reeling cable rated at 1.9/3.3 kV (25 mm² to 240 mm²) for underground 3.3 kV continuous miners, longwall shearers, jumbo drills, and open-cast mobile machinery. Constructed with Class 5 tinned annealed copper conductors, 3.3 kV EPR thermosetting insulation, 3 composite tinned-copper/nylon screened power cores + 3 interstitial pilot cores, 16-string open nylon anti-torsion braid, and heavy-duty black polychloroprene (CR) inner and outer sheaths.

Standard
SANS 1520-2; SANS 1411-1; SANS 1411-3
Rated Voltage
1.9 / 3.3 kV AC (Medium Voltage)
Core Architecture
3 Screened MV Power Cores + 3 Interstitial Pilots
Cross-Section & Ampacity
25–240 mm² (130 A to 520 A @ 30 °C)
Operating Temp. & Bend
-25 °C to +90 °C | Min. 6 × OD
Max. Tension & Fault
1.1–10.8 kN Pull | Up to 29 kA Sym. S/C (1s)
Engineering Datasheet: Download Verified SANS 1520-2 Type 63 PDF (3 Pages):

Application & Operating Conditions

SANS 1520-2 Type 63 is an unarmoured 1.9/3.3 kV medium-voltage flexible trailing and reeling cable manufactured to South African National Standard SANS 1520-2 to deliver primary 3.3 kV power (130 A to 520 A) to high-output underground continuous miners, longwall shearers, tunnel boring machines, and mobile open-cast mining equipment in hazardous areas.

3.3 kV Continuous Miners & Shearers

Covers nine standard cross-sections from 25 mm² up to 240 mm² (520 A continuous at 30 °C; 29 kA 1s symmetrical short-circuit) for modern high-tonnage 3.3 kV coal and hard-rock cutting faces.

Reeling & Non-Reeling Dynamic Service

Composite nylon/tinned-copper phase screens (31–64 mm² screen cross-section) flex repeatedly at 6 × OD without metallic work-hardening, while the 16-string open nylon braid handles up to 10.8 kN axial tension.

Three Interstitial Pilot Cores

Integrates three unscreened pilot/control cores (10 mm², 16 mm², or 25 mm²) nestled in the outer phase valleys for earth-continuity monitoring, pilot-relay interlocking, and telemetry.

Cross-Standard Identification Notice (SANS 1520-2 vs BS 6708): Do not confuse South African SANS 1520-2 Type 63 (unarmoured 1.9/3.3 kV medium-voltage flexible reeling/trailing cable, 25–240 mm²) with British Standard BS 6708 Type 63 (640/1100 V pliable steel-wire armoured roadway cable). Always verify both standard prefix and rated voltage before ordering couplers.

Cable Construction (SANS 1520-2 Type 63)

Manufactured to SANS 1520-2, SANS 1411-1, and SANS 1411-3, Type 63 balances medium-voltage 3.3 kV dielectric integrity with tight 6 × OD bending flexibility.

Layer / ComponentMaterial & SANS 1520-2 Engineering Specification
1. Power & Pilot ConductorsClass 5 flexible stranded tinned annealed copper to SANS 1411-1 (power cores 25–240 mm²; three interstitial pilot cores 10–25 mm²).
2. Medium-Voltage Insulation3.3 kV grade thermosetting Ethylene Propylene Rubber (EPR) compound to SANS 1411-3 rated for continuous +90 °C conductor temperature.
3. Composite Phase ScreensIndividual composite braid of 0.31 mm tinned copper wires and nylon yarn (31 mm² to 64 mm² screen cross-section) applied over each of the three MV power cores.
4. Six-Core Lay-Up & CentreThree composite-screened MV power cores (Red, Yellow, Blue) and three unscreened insulated pilot cores laid up symmetrically around a central rubber filler cradle.
5. Inner SheathExtruded heavy-duty Polychloroprene (CR) rubber inner bedding maintaining core geometry under reel compression.
6. Anti-Torsion ReinforcementOpen nylon reinforcement braid (minimum 16 strings) bonded between the inner and outer sheaths for axial tensile stability (1.1–10.8 kN).
7. Outer SheathHeavy-duty black Polychloroprene (CR) outer sheath resistant to abrasion, mine water, hydraulic oil, ozone, and flame propagation (optional TPU outer sheath available for severe rock-drag applications).
Cross-section diagram of SANS 1520-2 Type 63 Medium Voltage Trailing Cable 1.9/3.3kV

SANS 1520-2 Type 63 (25–240 mm²): 3 medium-voltage EPR power cores with composite tinned-copper/nylon braided screens + 3 interstitial pilot cores laid around a central rubber filler, with CR inner sheath, 16-string open nylon braid, and black CR outer sheath.

Composite Nylon / Tinned Copper MV Core Screens Heavy-Duty Black Polychloroprene (CR) Inner & Outer Sheath

Technical Characteristics

Verified electrical, fault-current, thermal, and mechanical specifications for SANS 1520-2 Type 63 1.9/3.3 kV trailing cables.

ParameterSANS 1520-2 Rated Value
Applicable StandardsSANS 1520-2; SANS 1411-1; SANS 1411-3
Rated Voltage (Uo/U)1.9 / 3.3 kV AC
Operating Temperature Range-25 °C to +90 °C
Minimum Bending Radius6 × Overall Cable Diameter (264 mm to 468 mm across 25–240 mm²)
Ambient Current Rating Basis130 A (25 mm²) to 520 A (240 mm²) Laid Out Straight at 30 °C Ambient
Installation UseReeling and Non-Reeling Operation for Portable & Mobile 3.3 kV Mining Equipment
Maximum Pulling Tension1.1 kN (25 mm²) up to 10.8 kN (240 mm²)
1-Second Fault RatingsSymmetrical S/C: 3.1–29 kA | Earth Fault: 1.6–4.1 kA (1s)

SANS 1520-2 Type 63 Complete Dimensional & Electrical Tables (9 Sizes)

Complete nominal dimensional, screen cross-section, tensile load, standardized mass (kg/km), impedance, current rating, and 1-second short-circuit tables for all nine 1.9/3.3 kV sizes.

1. SANS 1520-2 Type 63 — Dimensions, Screen Cross-Section, Tension & Nominal Weight (25–240 mm²)
Configuration (mm²)Power Wire Dia. (mm)Power Cond. Dia. (mm)Screen Wire Dia. (mm)Screen Area (mm²)Pilot Size (mm²)Pilot Wire Dia. (mm)Pilot Cond. Dia. (mm)Max. Tension (kN)Overall Dia. (mm)Nominal Weight (kg/km)
Type 63 3×25 + 3×100.416.80.3131100.414.21.144.03,600
Type 63 3×35 + 3×100.418.50.3133100.414.21.648.04,200
Type 63 3×50 + 3×100.4110.30.3138100.414.22.350.54,200
Type 63 3×70 + 3×160.5111.90.3142160.415.33.256.06,400
Type 63 3×95 + 3×160.5113.50.3147160.415.34.361.07,700
Type 63 3×120 + 3×160.5115.50.3150160.415.35.463.08,500
Type 63 3×150 + 3×250.5117.30.3155250.416.86.866.010,500
Type 63 3×185 + 3×250.5120.20.3160250.416.88.372.011,400
Type 63 3×240 + 3×250.5122.90.3164250.416.810.878.014,000
2. SANS 1520-2 Type 63 — DC Resistance, Reactance, Impedance, Current & 1s Fault Ratings
Configuration (mm²)DC Res. @ 20 °C (Ω/km)DC Res. @ 90 °C (Ω/km)Reactance (Ω/km)Impedance @ 90 °C (Ω/km)Current Laid Straight @ 30 °C (A)Sym. S/C 1s (kA)Earth Fault 1s (kA)
Type 63 3×25 + 3×100.8591.100.1221.111303.11.6
Type 63 3×35 + 3×100.6100.7780.1130.7861604.32.1
Type 63 3×50 + 3×100.4240.5420.1070.5522006.13.1
Type 63 3×70 + 3×160.2990.3820.1030.3962458.53.5
Type 63 3×95 + 3×160.2270.2900.0900.30429511.64.1
Type 63 3×120 + 3×160.1770.2270.0880.24334514.64.1
Type 63 3×150 + 3×250.1430.1830.0850.20239018.34.1
Type 63 3×185 + 3×250.1170.1500.0840.172440234.1
Type 63 3×240 + 3×250.08820.1150.0830.142520294.1
Engineering Mass & Pilot Verification Note: Nominal weights in Table 1 are standardized to true kg/km (3,600–14,000 kg/km, equivalent to 360–1,400 kg/100m) and verified for 10 mm² pilot conductor diameter (4.2 mm) so reel torque and shipping calculations remain exact.

SANS 1520-1 & SANS 1520-2 South African Mining Cable Selection Matrix

Compare Type 63 (1.9/3.3 kV medium-voltage trailing & reeling cable) across the complete SANS 1520 underground and open-cast voltage hierarchy from 640/1100 V up to 19/33 kV.

SANS 1520 ModelVoltage, Core & Pilot Architecture & Primary Mining Duty
SANS 1520-1 Type 41 (640/1100V)SANS 1520-1 Type 41 (640/1100V): 640/1100 V 4-core (3 composite-screened power cores + 1 unscreened pilot, 2.5–25 mm²) CR-sheathed reeling & trailing cable for drills, pumps, and portable underground tools.
SANS 1520-1 Type 61A (640/1100V TPU)SANS 1520-1 Type 61A (640/1100V TPU): 640/1100 V heavy-duty 6-core (3 composite-screened power cores + 3 interstitial pilots) reeling & trailing cable with abrasion-resistant TPU outer sheath (black or reflective transparent).
SANS 1520-1 Type 61B (0.64/1.1kV)SANS 1520-1 Type 61B (0.64/1.1kV): 0.64/1.1 kV 6-core (35–150 mm²) non-reeling coalface cable with triple-extruded RD 3 EPR, 80% tinned copper braid screens, 3 interstitial pilots, and RS 6 CR sheaths.
SANS 1520-2 Type 63 (1.9/3.3kV) (This Product)1.9/3.3 kV medium-voltage 6-core (25–240 mm², up to 520 A) composite-screened reeling & trailing cable for 3.3 kV continuous miners, shearers, and jumbo drills.
SANS 1520-2 Type 66 & 66-ECC (3.8/6.6kV)SANS 1520-2 Type 66 & 66-ECC (3.8/6.6kV): 3.8/6.6 kV screened reeling & section feeder cable (25–240 mm²) with 3 interstitial pilots (Type 66) or 2 pilots + 1 bare ECC earth conductor up to 17.0 kA 1s (Type 66-ECC).
SANS 1520-2 Type 611 & 611-ECC (6.35/11kV)SANS 1520-2 Type 611 & 611-ECC (6.35/11kV): 6.35/11 kV medium-voltage dragline, shovel, and reeling cable (25–240 mm²) with triple-extruded EPR insulation, strippable semi-con screen, and CR outer sheath.
SANS 1520-2 Type 622 & 622-ECC (12.7/22kV)SANS 1520-2 Type 622 & 622-ECC (12.7/22kV): 12.7/22 kV heavy-duty open-cast dragline, excavator, and mobile pit substation feeder cable (25–150 mm²) in 3-pilot or high-fault ECC topology.
SANS 1520-2 Type 633 & 633-ECC (19/33kV)SANS 1520-2 Type 633 & 633-ECC (19/33kV): 19/33 kV highest-voltage SANS 1520-2 screened reeling & pit feeder cable (25–120 mm²) delivering up to ~14.8 MVA three-phase bench capacity.

Frequently Asked Questions (FAQ)

Frequently asked engineering questions for 3.3 kV SANS 1520-2 Type 63 trailing and reeling cables.

How is SANS 1520-2 Type 63 decoded in the South African mining cable numbering system?

Under SANS 1520, the first digit “6” denotes a 6-core lay-up (3 individually screened power cores + 3 interstitial pilot/earth-continuity cores), and the following digits “3” indicate the 3.3 kV system voltage class (1.9/3.3 kV). Similarly, Type 66 is rated 3.8/6.6 kV, Type 611 is 6.35/11 kV, Type 622 is 12.7/22 kV, and Type 633 is 19/33 kV.

What is the difference between SANS 1520-2 Type 63 and UK BS 6708 Type 63?

Although both share the number “Type 63”, they belong to completely different national standards and voltage classes: South African SANS 1520-2 Type 63 is an unarmoured 1.9/3.3 kV flexible trailing/reeling cable for mobile machines, whereas British BS 6708 Type 63 is a 640/1100 V pliable galvanized-steel-wire armoured cable for semi-flexible roadway distribution.

Can SANS 1520-2 Type 63 be manufactured with a TPU outer sheath instead of CR?

Yes. Standard SANS 1520-2 Type 63 features a heavy-duty black Polychloroprene (CR) outer sheath for balanced flexibility, oil resistance, and flame retardance. For severe hard-rock shuttle-car or jumbo-drill reeling conditions, TEBAOFLEX can custom-extrude a high-visibility or black Thermoplastic Polyurethane (TPU) outer sheath.

How should current ratings be de-rated when Type 63 is coiled on a reeling drum?

The 130 A to 520 A values in Table 2 apply to single cables laid out straight in free air at 30 °C ambient. When operated dynamically on cylindrical or mono-spiral drums, apply SANS 1520-2 layer de-rating factors (typically 0.85 for 1 layer, 0.65 for 2 layers, and 0.45 for 3 layers) and ambient temperature correction above 30 °C.

Request a Quote for SANS 1520-2 Type 63 (1.9/3.3 kV) Cable

Send your required conductor cross-section (25 mm² to 240 mm²), coupler gland entry range, and drum cut lengths for direct factory pricing and routine HV test documentation.

Explore All Mining & Tunneling Cables
Standard

SANS 1520-2; SANS 1411-1; SANS 1411-3

Cable Type

Type 63 Medium Voltage Flexible Trailing & Reeling Mining Cable

Voltage Rating

1.9/3.3kV

Core Configuration

3 Composite-Screened MV Power Cores + 3 Unscreened Interstitial Pilots (25–240 mm²)

Conductor Material

Class 5 Flexible Stranded Tinned Annealed Copper

Insulation & Screen

3.3kV EPR Dielectric + Composite Tinned Copper / Nylon Braided Core Screens

Sheath Material

CR Inner Sheath + 16-String Open Nylon Braid + Heavy-Duty Black CR Outer Sheath

Application

3.3kV Continuous Miners, Longwall Shearers, Jumbo Drills, Reeling & Trailing Equipment