Home » Industrial Flexible & Special Cable Products » YSL11Y-JZ / LiY11Y-JZ 300/500 V Oil-Resistant PUR Flexible Industrial Control Cable

YSL11Y-JZ / LiY11Y-JZ 300/500 V Oil-Resistant PUR Flexible Industrial Control Cable

TEBAOFLEX YSL11Y-JZ / LiY11Y-JZ is a compact 300/500 V PVC-insulated, polyurethane (PUR 11Y) sheathed flexible industrial control cable engineered for CNC machine tools, wet assembly lines, cutting-oil splash zones, and abrasion-exposed actuator/sensor wiring.

Rated & Test Voltage300/500 V AC | 4,000 V Test
European ArchitectureYSL11Y-JZ / OZ (EN 50525-2-51 Ref.)
Conductors & CodingClass 5 Bare Cu | Black Numbered
Core / Sheath SystemPVC TI2 + Oil/Notch-Proof PUR 11Y
Temperature Range-5°C to +70°C Flex | -30°C Fixed
Min. Bending Radius12.5 × D Flexing | 4 × D Fixed

Send your core count (2×0.5 up to 61G or 4G16), jacket colour (Black RAL 9005 or Grey RAL 7001), and drum length to Request YSL11Y-JZ PUR Cable Quote.

TEBAOFLEX YSL11Y-JZ / LiY11Y-JZ 300/500 V PUR Industrial Control Cable combines EN 60228 Class 5 fine-stranded bare copper conductors and compact numbered PVC TI2 core insulation with a cut-, notch-, and oil-resistant polyurethane (PUR 11Y) outer sheath. Designed for wet and oily CNC machine tools, metalworking transfer lines, hydraulic valve manifolds, and industrial automation cells, it withstands mineral-oil lubricants, synthetic coolants, diluted acids, aqueous alkaline solutions, and floor abrasion where standard all-PVC control cables harden and split.

1. Application Scope & Industrial Control / Servo Cable Comparison

Hybrid PVC/PUR control architecture (YSL11Y-JZ / OZ) gives machine builders small termination diameters inside dense DIN-rail terminal blocks while armoring the external jacket against shop-floor fluids and mechanical wear:

  • CNC Machine Tools & Machining Cells: Solenoid valves, coolant-pump contactors, tool-changer sensors, and auxiliary actuator feeds exposed to cutting emulsions and metal swarf.
  • Assembly Lines, Packaging & Material Handling: Flexible cabinet-to-machine interconnects across wet washdown floors, conveyors, and transfer stations.
  • Measurement & Auxiliary Drive Wiring: 300/500 V control and instrumentation harnesses tested at 4,000 V AC.
TEBAOFLEX Control / Drive SeriesVoltage ClassShielding & SheathPrimary Machine Duty
YSL11Y-JZ / LiY11Y-JZ (This Page)300/500 V (4 kV Test)Unshielded | PVC TI2 + PUR 11YOily/wet machine tools, control valves & shop-floor automation
Heavy-Duty PUR Multi-Core Control300/500 V / 0.6/1 kVUnshielded Elastomer / PURSub-zero outdoor, reeling & high-flex mobile machinery control
SY Galvanized Steel-Braid Control300/500 VGSWB Mechanical Armour BraidCrush- & impact-exposed dry/indoor machine-tool interconnects
2YSLCY-JB EMC Shielded VFD Cable0.6/1 kVAl/PET Foil + Tinned Cu BraidMain PWM frequency-converter & AC servo spindle motor power

2. 4-Layer Cable Construction (YSL11Y-JZ / YSL11Y-OZ)

Constructed with short core lay lengths and high-grade polyurethane jacketing for smooth routing and clean gland sealing:

1. Conductors
Fine-stranded annealed bare electrolytic copper conforming to EN 60228 / IEC 60228 Class 5 (0.50 mm² up to 16 mm² and above).
2. PVC TI2 Core Insulation
Special thermoplastic PVC compound Type TI2 per EN 50363-3 / EN 50525-2-51 reference for thin radial wall and reliable ferrule crimping.
3. Core Coding (-JZ / -OZ)
Black cores printed with continuous sequential white numbers per DIN VDE 0293. JZ (G) configurations include one Green/Yellow protective earth core in the outer layer; 2-core OZ (×) configurations omit PE.
4. PUR 11Y Outer Sheath
Abrasion-, tear-, microbe-, coolant-, and mineral-oil-resistant polyurethane elastomer (PUR 11Y / TMPU) per EN 50363-10-2, supplied in Grey RAL 7001 or Matte Black RAL 9005.

3. Technical Characteristics

Confirmed electrical, mechanical, and chemical performance parameters for YSL11Y-JZ / LiY11Y-JZ 300/500 V:

ParameterEngineering Specification
Nominal Voltage (U0/U)300/500 V AC
AC Dielectric Test Voltage4,000 V AC (50 Hz high-margin insulation integrity test)
Operating Temperature RangeFlexible / occasional movement: -5°C to +70°C | Fixed installation: -30°C to +70°C
Minimum Bending RadiusFlexible routing: 12.5 × outer cable diameter | Fixed installation: 4 × outer cable diameter
Chemical & Oil ResistanceResistant to mineral oils (EN 60811-404), synthetic machining coolants, hydraulic fluids, diluted acids, and aqueous alkaline solutions
Mechanical & Weather DurabilityHigh notch, cut, and sliding-abrasion resistance; suitable for indoor wet zones and temporary outdoor use (Black RAL 9005 UV-stabilized)
Design ReferenceEN 50525-2-51 / DIN VDE 0285-525-2-51 core reference; RoHS & REACH compliant

EMC & Main Servo Power Selection Note: Use YSL11Y-JZ for unshielded 300/500 V machine-tool control, valve islands, limit switches, and auxiliary actuator circuits. Where frequency-converter PWM motor leads or analogue encoder signals require 360-degree copper EMC screening, view our screened control cables or full industrial & control cable catalog.

4. Standard Core Configuration, Diameter & Weight Schedule

Representative YSL11Y-OZ (2-core) and YSL11Y-JZ (3G to 25G, 0.50 mm² to 16 mm²) machine-tool sizes are listed below (custom core counts up to 61G available on request):

Part CodeConfiguration (mm²)Core CodingApprox. OD (mm)Copper Weight (kg/km)Approx. Cable Weight (kg/km)
YSL11Y-OZ-2X0.52 × 0.50 mm²OZ (2 Numbered, No PE)4.88.730
YSL11Y-JZ-3G0.53G × 0.50 mm²JZ (2 Numbered + G/Y)5.113.138
YSL11Y-JZ-7G0.57G × 0.50 mm²JZ (6 Numbered + G/Y)6.730.472
YSL11Y-JZ-3G0.753G × 0.75 mm²JZ (2 Numbered + G/Y)5.619.549
YSL11Y-JZ-5G0.755G × 0.75 mm²JZ (4 Numbered + G/Y)6.832.574
YSL11Y-JZ-12G0.7512G × 0.75 mm²JZ (11 Numbered + G/Y)10.178.0171
YSL11Y-JZ-4G1.04G × 1.00 mm²JZ (3 Numbered + G/Y)6.534.873
YSL11Y-JZ-7G1.07G × 1.00 mm²JZ (6 Numbered + G/Y)8.060.9118
YSL11Y-JZ-18G1.018G × 1.00 mm²JZ (17 Numbered + G/Y)13.2156.5311
YSL11Y-JZ-4G1.54G × 1.50 mm²JZ (3 Numbered + G/Y)7.350.998
YSL11Y-JZ-7G1.57G × 1.50 mm²JZ (6 Numbered + G/Y)9.189.1162
YSL11Y-JZ-25G1.525G × 1.50 mm²JZ (24 Numbered + G/Y)17.2318.3576
YSL11Y-JZ-4G2.54G × 2.50 mm²JZ (3 Numbered + G/Y)8.984.9152
YSL11Y-JZ-12G2.512G × 2.50 mm²JZ (11 Numbered + G/Y)14.8254.6443
YSL11Y-JZ-7G67G × 6 mm²JZ (6 Numbered + G/Y)16.5354.3566
YSL11Y-JZ-4G164G × 16 mm²JZ (3 Numbered + G/Y)18.8574.1852

5. Frequently Asked Engineering Questions

Why upgrade from standard YSLY-JZ (all-PVC) control cable to YSL11Y-JZ (PVC/PUR)?

Standard YSLY-JZ PVC control cables leach plasticizers, stiffen, and crack when exposed to CNC synthetic cutting emulsions, mineral hydraulic oils, diluted acids, alkaline washdowns, and metal-chip abrasion. YSL11Y-JZ retains compact, easy-stripping numbered PVC TI2 inner cores while replacing the outer jacket with notch-proof, oil- and microbe-resistant polyurethane (PUR 11Y).

What do the suffixes -JZ, -OZ, -JB, and -OB mean on YSL11Y control cables?

JZ denotes black numbered cores with a Green/Yellow protective earth core (3G and above); OZ denotes black numbered cores without a Green/Yellow core (standard on 2-core DC/valve leads such as 2 × 0.50 mm²). JB and OB denote colour-coded cores with or without Green/Yellow PE.

Can YSL11Y-JZ be used for servo motor or VFD power connections?

Unshielded YSL11Y-JZ (300/500 V, 4,000 V test voltage) is widely used for auxiliary servo actuator leads, 24 V brake/limit-switch circuits, stepper drives, and machine-tool control valves. However, main PWM inverter/VFD motor power leads above 300/500 V or EMC-regulated AC servo spindles should use our 0.6/1 kV EMC-shielded 2YSLCY-JB servo motor cable.

Which PUR outer sheath colours are available?

Both machine-tool Grey (RAL 7001) and UV-stabilized Matte Black (RAL 9005, as shown in our studio cutaway) are supplied as standard, with DESINA Orange (RAL 2003) or Blue (RAL 5015 intrinsically safe circuit coding) available on production runs.

Is YSL11Y-JZ suitable for continuous high-speed drag-chain duty?

Standard Class 5 YSL11Y-JZ is designed for fixed machine wiring and occasional free flexing (minimum bend radius 12.5 × D, -5°C to +70°C). If your application runs continuously inside high-cycle power drag chains or below -5°C, request our Class 6 extra-fine-stranded TPE/PUR drag-chain series.

What information is required to quote YSL11Y-JZ / OZ PUR control cable?

Provide the core count and conductor cross-section (e.g., 2 × 0.50 mm² OZ, 12G × 0.75 mm² JZ, or 25G × 1.50 mm² JZ), preferred jacket colour (Grey RAL 7001 or Black RAL 9005), exposure media (cutting oil, coolant, outdoor dampness), and total drum length.

Specify Your YSL11Y-JZ / LiY11Y-JZ 300/500 V PUR Control Cable

Share your required core count, conductor cross-section, Grey RAL 7001 or Black RAL 9005 jacket preference, coolant/oil exposure, and reel lengths. Our engineering team responds within 24 hours with datasheets and factory pricing.

Request PUR Control Cable Quote
Brand

TEBAOFLEX

Cable Designation

YSL11Y-JZ / YSL11Y-OZ (LiY11Y-JZ) PUR Control Cable

Cable Type

Oil- & Abrasion-Resistant Polyurethane (PUR) Industrial Control Cable

Rated Voltage

U0/U 300/500 V AC (Test Voltage: 4,000 V AC)

Conductor

Bare fine-stranded copper, EN 60228 Class 5

Core Insulation

Special PVC compound Type TI2

Core Identification

Black cores with continuous white numbers + Green/Yellow PE (-JZ) or without PE (-OZ)

Outer Sheath

Polyurethane (PUR 11Y / TMPU), Grey RAL 7001 or Black RAL 9005

Temperature Range

Flexible: -5°C to +70°C; Fixed installation: -30°C to +70°C

Minimum Bending Radius

12.5 × cable diameter (flexible); 4 × cable diameter (fixed)

Standards Reference

EN 50525-2-51 core reference; EN 60811-404 oil resistant; RoHS & REACH

Applications

CNC machine tools, wet/oily assembly lines, control panels & industrial automation