RG7H1R 3.6/6kV Airport Lighting Primary Cable
TEBAOFLEX RG7H1R is a medium-voltage primary cable for airfield lighting series circuits. It connects constant-current regulators with isolating transformers in airport ground-lighting installations, where dependable electrical performance, clear circuit identification and mechanical durability are essential.
The cable uses a compact stranded bare copper conductor, G7-type rubber insulation, semi-conductive layers and a red PVC sheath. Before specification, confirm the circuit voltage, installation route, conductor size and local project requirements.
Key Features
- Airport lighting application: designed for primary series circuits between constant-current regulators and isolating transformers.
- Medium-voltage construction: 3.6/6 kV rating for airfield ground-lighting cable systems.
- Screened design: semi-conductive layers and bare copper tape shielding support the specified construction.
- Red PVC sheath: provides clear visual identification for airport-lighting circuit routing.
Construction and Ratings
| Parameter | Specification |
|---|---|
| Product type | RG7H1R airport lighting primary cable |
| Rated voltage Uo/U | 3.6/6 kV |
| Conductor | Compact stranded bare copper |
| Inner semi-conductor | Extruded semi-conducting compound |
| Insulation | G7-type rubber compound |
| Outer semi-conductor | Extruded semi-conducting compound |
| Shield | Bare copper tapes |
| Outer sheath | Red PVC |
| Fixed-installation temperature rating | -50°C to +90°C |
| Minimum bending radius | 15 × overall diameter |
| Standard reference | EN 50575 |
Dimensions for the Listed Construction
| Nominal Cross-Sectional Area | Nominal Insulation Thickness | Minimum Shield Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight |
|---|---|---|---|---|---|
| 10 mm² | 2.3 mm | 0.075 mm | 1.4 mm | 14 mm | 305 kg/km |
These values describe the listed construction. Final dimensions and weight can vary with project-specific requirements, so TEBAOFLEX recommends reviewing the requested configuration before purchase.
Typical Applications
- Airfield ground-lighting primary circuits
- Series connections from constant-current regulators to isolating transformers
- Airport runway, taxiway and approach-lighting infrastructure
Selection Checklist
- Confirm the required 3.6/6 kV primary-circuit rating.
- Verify conductor size and the required route length.
- Allow for the 15 × overall-diameter minimum bend radius.
- Provide the installation environment and project standard for technical review.
Request a Quote
Send TEBAOFLEX the required conductor size, total length, installation conditions and delivery destination. Contact our technical sales team for an airport lighting cable quotation.
Related Cable Solutions
Explore industrial and control cables and high-temperature and specialty cables from TEBAOFLEX.
Frequently Asked Questions
What is RG7H1R cable used for?
It is used as a primary cable in airfield lighting series circuits, including connections between constant-current regulators and isolating transformers.
What is the voltage rating?
The listed RG7H1R construction is rated 3.6/6 kV.
Can TEBAOFLEX provide a technical review?
Yes. Provide the circuit rating, conductor size, length and installation conditions for review.