Home » Industrial Flexible & Special Cable Products » Fire Resistant LSZH Speaker & PA/GA Cable 300/500 V (BS 6387 Cat C) | TEBAOFLEX

Fire Resistant LSZH Speaker & PA/GA Cable 300/500 V (BS 6387 Cat C) | TEBAOFLEX

TEBAOFLEX 300/500 V Fire-Resistant LSZH Speaker & PA/GA Cable maintains emergency voice alarm (EVAC), public-address, and general-alarm audio circuit continuity during a fire. Engineered with annealed stranded tinned copper conductors, double-layer mica-glass fire barrier tape, cross-linked XLPE dielectric, and a grey low-smoke zero-halogen (LSZH) outer sheath tested to BS 6387 Category C (950°C for 3 hours).

Rated / Test Voltage300/500 V (2,000 V/min Test)
Fire Integrity RatingBS 6387 Cat C (950°C, 3 Hours)
Conductor & BarrierStranded Tinned Cu + Double Mica
Insulation / Outer JacketXLPE (Black/White) / Grey LSZH
Standard Cross-Sections2×1.5 to 2×6.0 mm² (+ 4-Core)
Operating Temperature-20°C to +105°C (-5°C Install)

Share your PA/VA speaker wattage, loop length, and fire-code specification to Request Fire-Resistant Speaker Cable Quote.

SKU: FIRE-RESISTANT-LSZH-SPEAKER Category: Tags: , , Brand:

TEBAOFLEX Fire-Resistant LSZH Speaker Cable (300/500 V) is a life-safety emergency voice alarm (EVAC), public-address, and general-alarm (PA/GA) audio cable engineered to maintain uninterrupted circuit integrity at 950°C for 3 hours under BS 6387 Category C. Combining annealed stranded tinned copper conductors, double-layer mica-glass fire barrier tape, thermoset XLPE insulation, and a grey low-smoke zero-halogen (LSZH) outer sheath, it ensures evacuation announcements remain audible while emitting minimal smoke and zero corrosive acid gases.

1. Application Scope & Life-Safety Cable Comparison

Emergency phased-evacuation and industrial PA/GA systems depend on speaker feeders remaining operational long after conventional PVC audio cables melt and short out:

  • Emergency Voice Alarm & Evacuation (EVAC / PA-VA): Constant-voltage 70 V / 100 V loudspeaker zones in metro stations, road/rail tunnels, airports, hospitals, and high-rise commercial complexes.
  • Industrial, Petrochemical & Power-Plant PA/GA Loops: Audible muster-alarm horns, beacons, and intercom circuits across refineries, LNG terminals, substations, and turbine halls.
  • Marine & Offshore Accommodation Modules: Low-smoke halogen-free audio distribution where tinned copper corrosion resistance and zero acid-gas emission protect personnel and sensitive control electronics.
TEBAOFLEX Safety / Signal CableVoltage RatingFire / Screen ArchitecturePrimary System Duty
Fire-Resistant LSZH Speaker — This Page300/500 VDouble Mica + XLPE + Grey LSZH (BS 6387 Cat C)100 V EVAC voice alarm & PA/GA loudspeaker loops
BFOU 0.6/1 kV Offshore Fire Cable0.6/1 kVMica + EPR + Halogen-Free Mud-Resistant SHF2IEC 60331-21 / NEK 606 offshore platform emergency power
Shielded Instrumentation Cable300/500 VOS / IS+OS Foil Screen (+ optional SWA / LSZH)4–20 mA / HART process telemetry & PLC analog pairs
SY LSZH Braided Control Cable300/500 VGalvanized steel wire braid (GSWB) + LSZHMechanically protected indoor/plant control interconnections

2. Cable Construction (Authentic 4-Layer Fire-Survival Build)

Each layer visible in the cutaway is engineered so inorganic fire barriers remain intact even after polymeric layers char during prolonged flame exposure:

1. Conductor
Annealed stranded tinned copper conductors providing low loop resistance, smooth conduit pulling, and superior resistance to humidity, sulphur, and high-temperature oxidation.
2. Double Fire Barrier
Double-layer phlogopite mica-glass fire barrier tape helically lapped with generous overlap over every conductor, forming a high-dielectric mineral shell at 950°C.
3. Core Insulation
Thermoset cross-linked polyethylene (XLPE) rated to +105°C operating temperature with high insulation resistance (≥ 2,000 MΩ-km); standard polarity pair in Black and White (Red/Black or 4-core A/B zone colour coding available).
4. Outer Sheath (LSZH)
Extruded grey Low-Smoke Zero-Halogen (LSZH) outer jacket (optional Red or Orange fire-identification sheath; optional overall Al/PET foil + tinned drain wire screen on request).

3. Electrical, Fire-Integrity & Mechanical Characteristics

Routine dielectric, fire-survival, and ageing test requirements for TEBAOFLEX 300/500 V Fire-Resistant LSZH Speaker Cable:

Test / ParameterVerified Engineering Requirement
Rated Voltage U0/U300/500 V
AC Dielectric Voltage Test2,000 V / min without breakdown
Minimum Insulation Resistance (20°C)≥ 2,000 MΩ-km
Fire-Resistance Circuit IntegrityBS 6387 Category C: no interruption of service at 950°C continuous flame for 3 hours (full BS 6387 CWZ & IEC 60331-21 builds available)
Smoke & Halogen PerformanceLow-smoke zero-halogen jacket compliant with IEC 60754-1/2 (halogen-free, low acidity) & IEC 61034-2 (high light transmittance)
Operating & Installation TemperatureOperating: -20°C to +105°C; installation pulling: -5°C to +75°C
Jacket Tensile & Elongation (Unaged)Tensile strength ≥ 10 MPa; elongation at break ≥ 125%
Thermal Ageing Retention & Cold BendAged tensile strength & elongation ≥ 70% of unaged value; cold bend at -20°C for 4 hours with no crack

4. Dimensional Schedule & 100 V Speaker Loop Sizing Guide

Standard two-core configurations and optional four-core dual-circuit (A+B redundant) PA/GA builds are listed below:

Part CodeConstructionXLPE Wall (mm)Core Insulation OD (mm)LSZH Jacket Wall (mm)Nominal Overall OD (mm)Max. Pull Tension (N)Max. DC Resistance @ 20°C (Ω/km)Approx. Weight (kg/km)
FR-LSZH-SPK-2X1.52 × 1.5 mm²0.74.20.810.018012.2112
FR-LSZH-SPK-2X2.52 × 2.5 mm²0.84.81.011.63007.6158
FR-LSZH-SPK-2X4.02 × 4.0 mm²0.85.21.012.44004.7205
FR-LSZH-SPK-2X6.02 × 6.0 mm²0.85.81.214.04503.1282
FR-LSZH-SPK-4X1.54 × 1.5 mm² (Dual A/B)0.74.21.012.236012.2196
FR-LSZH-SPK-4X2.54 × 2.5 mm² (Dual A/B)0.84.81.113.85507.6278

100 V Line Emergency Voice Alarm Maximum One-Way Route Length (10% Drop / ≤ 1 dB Loss at 20°C)

Conductor Cross-SectionLoop DC Resistance (2 × R @ 20°C)Max. Route @ 100 W Load (100 Ω)Max. Route @ 200 W Load (50 Ω)Max. Route @ 500 W Load (20 Ω)
2 × 1.5 mm²24.4 Ω/km450 m225 m90 m
2 × 2.5 mm²15.2 Ω/km720 m360 m145 m
2 × 4.0 mm²9.4 Ω/km1,170 m585 m235 m
2 × 6.0 mm²6.2 Ω/km1,770 m885 m355 m

Fire-Zone Support & Pulling-Tension Note: During conduit installation, never exceed the rated 180–450 N maximum pulling tension so the underlying double mica-glass fire barrier tape is not creased. Fix horizontal and vertical containment runs with stainless-steel fire-rated P-clips and ceramic terminal blocks rather than plastic cable ties. Explore our complete industrial & control cable catalog for companion fire-alarm and control circuits.

5. Frequently Asked Engineering Questions

How does double mica-glass tape keep a speaker circuit working at 950°C?

During a severe building, tunnel, or industrial plant fire, organic XLPE and LSZH polymers eventually pyrolyze into ash above 400–500°C. The overlapping double-layer phlogopite mica-glass tape wrapped directly over each stranded tinned-copper conductor sinters into an inorganic ceramic dielectric shell that prevents conductor-to-conductor short circuits at 950°C for 3 hours under BS 6387 Category C.

What is the difference between fire-retardant LSZH cable and fire-resistant LSZH cable?

A flame-retardant LSZH cable (IEC 60332-1 / IEC 60332-3) restricts flame spread and limits toxic halogen gas, but its circuit fails shortly after direct flame impingement. A fire-resistant LSZH cable adds double mica fire-barrier tapes so emergency voice alarm (EVAC) and PA/GA loudspeakers continue broadcasting evacuation instructions throughout a 3-hour 950°C fire.

How do I size 1.5 mm², 2.5 mm², 4.0 mm², or 6.0 mm² cable for a 100 V line PA/VA speaker loop?

On a 100 V constant-voltage voice alarm line (load impedance Z = 10,000 / Watts), keeping cable loop voltage drop within 10% (approx. 1 dB insertion loss) requires loop resistance R_loop ≤ 0.11 × Z. At 200 W speaker load (50 Ω), 2×1.5 mm² supports up to 225 m, 2×2.5 mm² up to 360 m, 2×4.0 mm² up to 585 m, and 2×6.0 mm² up to 885 m one-way route length at 20°C (apply a 1.35× temperature factor if sizing for hot-fire loop resistance).

Can TEBAOFLEX supply BS 6387 CWZ, foil-screened, or red/orange jacketed versions?

Yes. Beyond the standard unscreened grey LSZH BS 6387 Category C build, we manufacture full BS 6387 Category C, W, Z (950°C flame + water spray + mechanical shock), overall aluminium/PET foil + tinned-copper drain-wire screened PA/GA cables to eliminate 50/60 Hz hum near power trays, and red or orange LSZH jackets for fire-circuit visual segregation.

Why are stranded tinned copper conductors used instead of solid bare copper?

Stranded tinned copper pulls smoothly through tight containment conduits within the rated 180–450 N tension limits, resists moisture and salt-mist oxidation in coastal, tunnel, and offshore plant junction boxes, and avoids brittle copper scaling when exposed to high-temperature fire conditions.

What details should be submitted for a fire-resistant speaker cable quotation?

Send the core count and cross-section (e.g., 2×1.5 mm², 2×2.5 mm², 2×4.0 mm², 2×6.0 mm², or 4-core A/B loop), screening requirement (unscreened or AL/PET foil + drain wire), required fire test standard (BS 6387 Cat C, CWZ, or IEC 60331), outer jacket colour, and total drum or reel quantities.

Request a Factory Quote for Fire-Resistant LSZH Speaker & PA/GA Cable

Submit your speaker zone cross-sections, screening or BS 6387 CWZ / IEC 60331 fire-test specification, sheath colour, and drum quantities. Our engineering team will return a technical datasheet and quotation within 24 hours.

Request Fire-Resistant Cable Quote
Brand

TEBAOFLEX

Product Type

Fire-Resistant LSZH Speaker & Emergency PA/GA Cable

Rated & Test Voltage

300/500 V (2,000 V AC for 1 min dielectric test)

Conductor

Annealed stranded tinned copper (IEC 60228 Class 2 / flexible stranded)

Fire Barrier Layer

Double-layer phlogopite mica-glass fire barrier tape over each conductor

Core Insulation

Cross-linked polyethylene (XLPE), Black & White cores (4-core optional)

Outer Sheath

Grey Low-Smoke Zero-Halogen (LSZH) compound (Red / Orange optional)

Standard Sizes

2 × 1.5 mm², 2 × 2.5 mm², 2 × 4.0 mm², 2 × 6.0 mm² (+ 4 × 1.5 / 4 × 2.5 mm²)

Insulation Resistance

>= 2,000 MΩ-km at 20°C

Operating & Install Temp

-20°C to +105°C operating; -5°C to +75°C installation; -20°C 4h cold bend no crack

Mechanical Properties

>= 10 MPa tensile strength, >= 125% elongation (>= 70% retained after ageing)

Fire & Smoke Standards

BS 6387 Category C (950°C, 3h); CWZ, IEC 60331, IEC 60754 & IEC 61034 options