Home » Industrial Flexible & Special Cable Products » YY / YSLY-JZ & -OZ 300/500 V Flexible PVC Control Cable | Industrial Automation & Machine Wiring

YY / YSLY-JZ & -OZ 300/500 V Flexible PVC Control Cable | Industrial Automation & Machine Wiring

TEBAOFLEX YY / YSLY-JZ & -OZ 300/500 V Control Cable is a multi-core unshielded flexible PVC interconnecting cable for PLC control cabinets, CNC machine tools, conveyor lines, and HVAC plant wiring. Manufactured to DIN VDE 0281 / BS EN 50525-2-11 design principles with IEC 60228 Class 5 bare copper conductors, white-numbered black TI1 PVC cores (plus Green/Yellow earth on JZ), and an oil-resistant grey RAL 7001 PVC outer sheath.

Core Coding VariantsYSLY-JZ (G/Y) | -OZ | -JB (Colour)
Rated / Test Voltage300/500 V (2,000–4,000 V AC Test)
Conductor StrandingIEC 60228 Class 5 Fine Bare Cu
Insulation / Outer SheathPVC TI1 / Grey PVC TM2 (RAL 7001)
Cross-Sections & Cores0.5 to 35 mm² | 2 to 61 Cores
Operating Temperature-40°C to +80°C Fixed | -5°C Flex

Send your core count, cross-section, JZ/OZ/JB coding preference, and drum quantities to Request YY / YSLY Cable Quote.

TEBAOFLEX YY / YSLY-JZ & -OZ (300/500 V) is the European-standard multi-core unshielded flexible PVC control and interconnecting cable for industrial automation, machine-tool wiring, PLC switchgear panels, conveyor lines, and HVAC control installations. Built in accordance with DIN VDE 0281 / BS EN 50525-2-11 / IEC 60227 principles using IEC 60228 Class 5 fine bare copper conductors, white-numbered black TI1 PVC cores, and a compact silver-grey RAL 7001 TM2 PVC outer jacket, it routes cleanly around tight 4 × D cabinet bends.

1. Application Scope & YY / SY / CY Control Cable Selection

OEM panel builders and plant maintenance engineers rely on YY (YSLY) wherever space-saving multi-core flexibility is required for fixed or occasionally flexed indoor control circuits:

  • PLC Switchgear & Control Cabinets: High-density multi-core terminal-strip interconnects (up to 61 cores) between main enclosures, remote I/O islands, limit switches, and operator push-button stations.
  • CNC Machine Tools, Packaging & Conveyor Lines: Fixed cable-tray runs and vibration-tolerant flexible drops feeding relays, pneumatic valve banks, and small three-phase auxiliary motors.
  • HVAC, Building Management & Process Instrumentation: Damper actuators, pump starters, and low-voltage telemetry in dry, damp, or lightly oil-misted plant rooms.
TEBAOFLEX Control / Automation TypeScreen / ArmourInsulation / SheathRecommended Plant Environment
YY / YSLY-JZ & -OZ — This PageUnshielded / UnarmouredPVC TI1 / Grey PVC TM2 (RAL 7001)General indoor automation, cabinets & machine drops
SY Steel-Wire-Braided CableGalvanized steel wire braid (GSWB)PVC or LSZH / Transparent jacketMachine-shop swarf, abrasion & mechanical crush zones
2YSLCY-JB EMC Shielded CableAl/PET Foil + Tinned Cu BraidLow-capacitance PE / PVCEMI-noisy VFD motor drives & EMC-sensitive cabinets
LSZH Round Automation CableUnshielded Low-Smoke Zero-HalogenHalogen-Free / Grey LSZHPublic buildings, tunnels & halogen-free cleanrooms

2. Cable Construction & YSLY Core Identification Codes

As seen in our factory cross-section photograph above, TEBAOFLEX YY / YSLY uses tightly concentric core stranding with zero bulky fillers for effortless gland termination:

1. Flexible Conductor
Fine-stranded annealed bare copper wires in accordance with IEC 60228 / DIN VDE 0295 Class 5.
2. Core Insulation
Extruded flexible PVC compound (type TI1 / YI2 per BS EN 50363-3 / DIN VDE 0207-4) with high dielectric strength and clean stripping.
3. Core Identification (VDE 0293)
YSLY-JZ (G): Black cores with sequential white numerals + 1 Green/Yellow protective-earth core in the outer layer (3 cores & up).
YSLY-OZ (×): All black cores with sequential white numerals, no Green/Yellow core (standard on 2-core and isolated DC control).
YSLY-JB / -OB: Colour-coded cores per HD 308 S2 / VDE 0293-308 with (JB) or without (OB) Green/Yellow earth.
4. Concentric Layer Assembly
Cores stranded in concentric layers with optimized pitch lengths and non-hygroscopic separating tape where required for circular gland sealing.
5. Outer Sheath
Flexible oil- and chemical-resistant PVC compound (type TM2 / YM2 per BS EN 50363-4-1) in standard silver-grey RAL 7001 (UV-stabilized Black RAL 9005 or Blue intrinsic-safety jacket available to order).

3. Technical Characteristics

Electrical, thermal, and mechanical ratings for TEBAOFLEX 300/500 V YY / YSLY Control Cable:

ParameterEngineering Specification
Rated Voltage U0/U300/500 V (heavy-duty 0.6/1 kV YSLY-JZ Black/Grey power-control build also available)
AC Dielectric Test Voltage4,000 V AC (50 Hz, 5 min per DIN VDE 0281 / 2,000 V routine spark/voltage test)
Minimum Insulation Resistance (20°C)≥ 20 MΩ-km
Operating Temperature RangeFixed installation: -40°C to +80°C; occasional free flexing: -5°C to +70°C
Maximum Short-Circuit Temperature+160°C on conductor (up to 5 seconds)
Minimum Bending RadiusFixed installation: 4 × cable diameter; occasional flexing without tensile stress: 15 × cable diameter
Flame Retardancy & ComplianceSelf-extinguishing per IEC 60332-1-2 / EN 60332-1-2; RoHS, REACH & CE Low-Voltage Directive compliant

Installation Boundary Note: Standard grey RAL 7001 YY / YSLY cable is engineered for indoor fixed tray/conduit routing and occasional tension-free movement, not continuous reciprocation inside energy chains or unshielded outdoor burial. For direct burial or concrete trenches, specify our CVV-SWA 600 V Steel-Wire-Armoured Control Cable; browse all options in industrial & control cables.

4. Popular YY / YSLY-JZ & -OZ Dimensional & Ampacity Schedule

Representative 300/500 V multi-core sizes from 0.5 mm² to 16 mm² are listed below (reference current ratings in air at 30°C for 3 loaded cores; apply multi-core grouping derating per DIN VDE 0298-4 for 5+ loaded control cores):

Part CodeCores × SizeCoding TypeNominal OD (mm)Min. Fixed Bend 4×D (mm)Copper Index (kg/km)Approx. Weight (kg/km)Ref. Current @ 30°C (A)
YSLY-OZ-2X0.52 × 0.5 mm²OZ (No G/Y)4.8209.6356
YSLY-JZ-3G0.53G0.5 mm²JZ (+ G/Y)5.12114.4426
YSLY-JZ-7G0.57G0.5 mm²JZ (+ G/Y)6.72733.6796
YSLY-JZ-12G0.512G0.5 mm²JZ (+ G/Y)8.93657.61316
YSLY-OZ-2X0.752 × 0.75 mm²OZ (No G/Y)5.32214.44410
YSLY-JZ-3G0.753G0.75 mm²JZ (+ G/Y)5.62321.65310
YSLY-JZ-5G0.755G0.75 mm²JZ (+ G/Y)6.72736.07910
YSLY-JZ-7G0.757G0.75 mm²JZ (+ G/Y)7.33050.410410
YSLY-JZ-12G0.7512G0.75 mm²JZ (+ G/Y)9.84086.417410
YSLY-JZ-3G1.03G1.0 mm²JZ (+ G/Y)5.92428.86312
YSLY-JZ-5G1.05G1.0 mm²JZ (+ G/Y)7.12948.09612
YSLY-JZ-7G1.07G1.0 mm²JZ (+ G/Y)8.03267.212912
YSLY-JZ-12G1.012G1.0 mm²JZ (+ G/Y)10.442115.221212
YSLY-JZ-18G1.018G1.0 mm²JZ (+ G/Y)12.550172.831012
YSLY-JZ-3G1.53G1.5 mm²JZ (+ G/Y)6.72743.28416
YSLY-JZ-4G1.54G1.5 mm²JZ (+ G/Y)7.33057.610416
YSLY-JZ-7G1.57G1.5 mm²JZ (+ G/Y)8.936100.816816
YSLY-JZ-12G1.512G1.5 mm²JZ (+ G/Y)11.948172.828216
YSLY-JZ-25G1.525G1.5 mm²JZ (+ G/Y)16.968360.057216
YSLY-JZ-4G2.54G2.5 mm²JZ (+ G/Y)8.93696.016122
YSLY-JZ-7G2.57G2.5 mm²JZ (+ G/Y)11.044168.026422
YSLY-JZ-25G2.525G2.5 mm²JZ (+ G/Y)20.683600.089522
YSLY-JZ-4G44G4 mm²JZ (+ G/Y)10.743153.624230
YSLY-JZ-5G65G6 mm²JZ (+ G/Y)13.856288.041838
YSLY-JZ-5G105G10 mm²JZ (+ G/Y)17.470480.068552
YSLY-JZ-5G165G16 mm²JZ (+ G/Y)21.285768.01,04569

5. Frequently Asked Engineering Questions

Are YY control cable and YSLY control cable the same specification?

Yes. YY is the UK/BS nomenclature (PVC core insulation Y + PVC outer sheath Y), while YSLY is the continental European / VDE designation (Y PVC insulation + SL control cable + Y PVC sheath). Both describe the same 300/500 V unshielded Class 5 flexible copper multi-core industrial control cable with a grey RAL 7001 PVC outer jacket.

What do the suffixes YSLY-JZ, YSLY-OZ, YSLY-JB, and YSLY-OB mean?

In DIN VDE 0293 core coding: JZ (also denoted with G, e.g., 12G1.5) means black cores with white numbers plus one Green/Yellow protective-earth core in the outer layer; OZ (denoted with ×, e.g., 2×0.75) means black cores with white numbers and no Green/Yellow core; JB means colour-coded cores per HD 308 S2 with a Green/Yellow core; and OB means colour-coded cores without a Green/Yellow core.

How do I choose between YY (YSLY), SY, and CY control cables?

Choose YY / YSLY (this page) for general dry or damp indoor machine wiring, control cabinets, and conduit trays free from heavy mechanical impact or high electromagnetic interference (EMI). Choose SY (galvanized steel wire braid) where swarf, crushing, or foot traffic requires mechanical armour, and choose 2YSLCY / CY copper-screened cable where PLC analog signals or VFD motor leads require 360-degree EMC shielding.

Can YY / YSLY control cable be used in continuous drag chains or outdoors?

Standard YY / YSLY is designed for fixed installation (4 × D bend radius, -40°C to +80°C) and occasional free, non-recurring flexing without tensile load (15 × D bend radius, -5°C to +70°C), not continuous high-cycle drag chains or unprotected direct sunlight. For outdoor UV exposure specify our black UV-stabilized PVC sheath option, and for continuous drag chains request Class 6 PUR-sheathed motion cables.

What voltage and flame-retardant standards does TEBAOFLEX YY / YSLY meet?

Standard YY / YSLY control cables are rated 300/500 V (with 0.6/1 kV heavy-wall YSLY-JZ 1kV power/control variants available on request), factory dielectric-tested up to 4,000 V AC, and self-extinguishing in accordance with IEC 60332-1-2 / EN 60332-1-2.

What details are required for a YY / YSLY control cable factory quotation?

Provide your required core count and conductor size (e.g., 2×0.75 mm² OZ, 7G1.5 mm² JZ, 18G1.0 mm² JZ, or 5G6 mm² JZ), core identification code (JZ, OZ, JB, or OB), outer jacket colour (standard RAL 7001 grey or UV black), and drum or reel lengths.

Request a Factory Quote for YY / YSLY-JZ & -OZ 300/500 V Control Cable

Submit your multi-core BOM schedule, JZ/OZ/JB coding requirement, sheath colour, and OEM reel or export drum quantities. Our industrial control cable team will confirm pricing and lead times within 24 hours.

Request YY / YSLY Cable Quote
Brand

TEBAOFLEX

Product Model

YY / YSLY-JZ, YSLY-OZ, YSLY-JB & YSLY-OB Flexible Control Cable

Rated & Test Voltage

300/500 V (4,000 V AC dielectric test; 0.6/1 kV variant optional)

Conductor

Fine-stranded bare copper per IEC 60228 / DIN VDE 0295 Class 5

Core Insulation

PVC compound type TI1 / YI2 per BS EN 50363-3 / DIN VDE 0207-4

Core Identification

JZ: Black numbered + G/Y earth, OZ: Black numbered, JB/OB: Colour-coded

Outer Sheath

PVC compound type TM2 / YM2, Silver-Grey RAL 7001 (UV Black optional)

Cross-Section & Core Range

0.5 mm² to 35 mm²; 2 cores up to 61 cores

Operating Temperature

-40°C to +80°C fixed installation; -5°C to +70°C occasional flexing

Minimum Bending Radius

4 × cable diameter (fixed); 15 × cable diameter (occasional flexing)

Flame & Oil Performance

IEC 60332-1-2 / EN 60332-1-2 flame retardant; industrial oil & chemical resistant

Reference Standards

DIN VDE 0281 / 0285, BS EN 50525-2-11, IEC 60227, HD 21.13