Single-Core Rubber Interconnecting Cable for Industrial Power Connections
This flexible single-core rubber cable is specified for electrical interconnections between mobile or stationary industrial equipment where a single insulated power conductor is required. The construction combines fine-stranded tinned copper, rubber insulation and a black chloroprene outer sheath. Select the voltage class and conductor cross-section to match the installation, protective devices and project drawings.
Voltage and Size Options
| Rated voltage | Reference conductor cross-sections | Configuration |
|---|---|---|
| 0.6/1 kV | 1 × 35–300 mm² | Single core |
| 1.8/3 kV | 1 × 35–300 mm² | Single core |
| 3.6/6 kV | 1 × 35–400 mm² | Single core |
These are reference ranges from the source technical material, not a statement that every size is in stock. Confirm the selected variant, outer diameter and detailed construction before ordering.
Cable Construction
| Layer | Specified material |
|---|---|
| Conductor | Fine-stranded tinned copper, Class 5 |
| Separator | Separation foil |
| Insulation | Rubber compound |
| Outer sheath | Black chloroprene rubber compound |
Technical Data and Selection Boundaries
| Parameter | Reference value or selection note |
|---|---|
| Core count | 1 |
| Rated voltage | 0.6/1 kV; 1.8/3 kV; or 3.6/6 kV, depending on selected construction |
| Maximum conductor temperature | +90 °C |
| Low-temperature reference | Down to −40 °C in the source material; installation and handling limits require confirmation for the ordered construction |
| Minimum bending radius | Confirm for the selected outside diameter and movement regime |
| Applicable standard and certification | Specify the required edition and project approval; no certification is implied by this page |
Where This Cable Fits
Typical enquiries include flexible equipment interconnections, protected power links, industrial machinery and mining-related equipment. Distinguish a stationary interconnection from continuous reeling or trailing: dynamic movement, cable supports, weather exposure, oil contact and mechanical loads must be checked against the final construction. This single-core product is not a substitute for a screened medium-voltage mining trailing assembly without an engineering review.

Specify Your Cable
Send the rated voltage, required cross-section, route length, bend geometry, movement frequency, ambient conditions, termination details and required documentation. TEBAOFLEX can review conductor size, sheath marking, cut lengths and packing against the confirmed project specification.
Explore the industrial and control cable range or send your requirements for a technical quote.