Home » Industrial Flexible & Special Cable Products » (N)TSCGECWOEU 3.6/6–18/30 kV TBM Reeling Cable

(N)TSCGECWOEU 3.6/6–18/30 kV TBM Reeling Cable

(N)TSCGECWOEU is a medium-voltage reeling cable for tunnel boring machines (TBMs) and reel-fed tunnel power systems. The related (N)TSCGECWÖU spelling has a separate dimensional schedule; select the exact variant rather than treating the two schedules as interchangeable.

  • Voltage classes: 3.6/6 to 18/30 kV across the two documented variants; available sizes differ by schedule.
  • Core design: three Class 5 tinned-copper power cores, three control cores, protective-earth braids and a concentric monitoring conductor.
  • Outer sheath: red 5GM5 elastomer. Fixed-duty temperature: −40 to +90 °C; moving-duty lower limit depends on the selected variant.

Send Your Requirements with voltage, conductor size and reel duty for a build-specific review.

Medium-voltage TBM reeling cable for tunnel power supply

(N)TSCGECWOEU is a screened, flexible medium-voltage power cable designed for reel-fed tunnel boring machines. It combines three power cores with control, protective-earth and monitoring elements in one rubber-sheathed cable. This layout helps engineers specify TBM power transmission and cable-monitoring functions together, while the exact monitoring circuit and termination must be confirmed for the selected machine.

TEBAOFLEX has two related technical schedules: (N)TSCGECWOEU and (N)TSCGECWÖU. Their names look similar, but the listed diameters, weights and temperature limits are not identical. Quote or order against the exact schedule and core configuration.

Choose the correct voltage and source variant

Datasheet variantListed voltage gradesMoving-duty temperaturePublished dimension rows
(N)TSCGECWOEU6/10, 8.7/15, 12/20, 14/25 and 18/30 kV−20 to +90 °C6/10 through 18/30 kV, by listed configuration
(N)TSCGECWÖU3.6/6, 6/10, 8.7/15, 12/20 and 18/30 kV−25 to +90 °C3.6/6, 6/10 and 12/20 kV in the supplied schedule

The second schedule names 8.7/15 and 18/30 kV as voltage grades but does not supply dimensional rows for those grades. Ask for a build-specific drawing and datasheet before specifying them.

Where this cable is used

Typical applications are TBM power reels and mobile medium-voltage supplies in tunnel construction. The cable should be specified against the actual reel geometry, route, travel speed, pulling force and electrical load; the published limits are not a blanket approval for every mining, tunnelling or continuous-flex installation.

Cable construction and monitoring elements

ComponentDocumented construction
Power conductorsThree Class 5 tinned-copper conductors
Insulation and field controlEPR rubber with inner and outer semiconductive layers
Protective earthCopper/textile braid around each power core
Control coresThree control cores positioned in the outer interstices
Monitoring conductorOverall concentric copper-wire lay; confirm the monitoring circuit and termination with the equipment designer
SheathsGM1B inner sheath and red 5GM5 elastomer outer sheath
Cross-section diagram of (N)TSCGECWOEU TBM Medium-Voltage Reeling Cable with centered TEBAOFLEX CABLE watermark
Cross-section illustration; not to scale. Confirm the selected build before ordering.

Operating limits and engineering checks

Selection itemDocumented value or required check
Fixed-duty temperature−40 to +90 °C in both technical schedules
Moving-duty temperature−20 to +90 °C for (N)TSCGECWOEU; −25 to +90 °C for (N)TSCGECWÖU
Travel and torsionUp to 30 m/min and ±25°/m are stated in the technical schedules; verify duty cycle and selected build
Tensile loadingThe (N)TSCGECWOEU schedule states 15 N/mm² for reeling and 30 N/mm² for TBM duty; confirm the applicable operating case
Reel and bend geometryConfirm minimum bend radius, S-turn distance and reel dimensions for the chosen outside diameter and installation arrangement
Current ratingCheck conductor size against the installation method, ambient temperature, grouping and load. Any datasheet current figures apply only under their stated reference conditions.

Dimensions by voltage and configuration

Nominal values from the company datasheet. Dimensions and weights may vary within manufacturing tolerances; electrical ratings depend on the stated installation conditions.

Source variantVoltage (kV)ConfigurationOD min (mm)OD max (mm)Weight (kg/km)
(N)TSCGECWOEU6/103×25 + 3×16/3E + 3×2.5ST + 6UELKON43463030
(N)TSCGECWOEU6/103×35 + 3×25/3E + 3×2.5ST + 6UELKON45.748.73600
(N)TSCGECWOEU6/103×50 + 3×25/3E + 3×2.5ST + 6UELKON47.951.94190
(N)TSCGECWOEU6/103×70 + 3×35/3E + 3×2.5ST + 6UELKON54.658.65550
(N)TSCGECWOEU6/103×95 + 3×50/3E + 3×2.5ST + 6UELKON58.362.36630
(N)TSCGECWOEU6/103×120 + 3×70/3E + 3×2.5ST + 6UELKON62.166.17840
(N)TSCGECWOEU6/103×150 + 3×70/3E + 3×2.5ST + 6UELKON66.670.68490
(N)TSCGECWOEU6/103×185 + 3×95/3E + 3×2.5ST + 6UELKON73.177.110860
(N)TSCGECWOEU6/103×240 + 3×120/3E + 3×2.5ST + 6UELKON80.784.713820
(N)TSCGECWOEU8.7/153×25 + 3×16/3E + 3×2.5ST + 6UELKON46.449.43210
(N)TSCGECWOEU8.7/153×35 + 3×25/3E + 3×2.5ST + 6UELKON48.752.73730
(N)TSCGECWOEU8.7/153×50 + 3×25/3E + 3×2.5ST + 6UELKON53.757.74700
(N)TSCGECWOEU8.7/153×70 + 3×35/3E + 3×2.5ST + 6UELKON58625990
(N)TSCGECWOEU8.7/153×95 + 3×50/3E + 3×2.5ST + 6UELKON61.665.67080
(N)TSCGECWOEU8.7/153×120 + 3×70/3E + 3×2.5ST + 6UELKON67.271.28490
(N)TSCGECWOEU12/203×25 + 3×16/3E + 3×2.5ST + 6UELKON48.852.83740
(N)TSCGECWOEU12/203×35 + 3×25/3E + 3×2.5ST + 6UELKON51.355.34270
(N)TSCGECWOEU12/203×50 + 3×25/3E + 3×2.5ST + 6UELKON56.760.75270
(N)TSCGECWOEU12/203×70 + 3×35/3E + 3×2.5ST + 6UELKON61.365.36390
(N)TSCGECWOEU12/203×95 + 3×50/3E + 3×2.5ST + 6UELKON66.470.47770
(N)TSCGECWOEU12/203×120 + 3×70/3E + 3×2.5ST + 6UELKON70.274.29160
(N)TSCGECWOEU12/203×150 + 3×70/3E + 3×2.5ST + 6UELKON71.175.19820
(N)TSCGECWOEU12/203×185 + 3×95/3E + 3×2.5ST + 6UELKON71.275.210200
(N)TSCGECWOEU12/203×240 + 3×120/3E + 3×2.5ST + 6UELKON74.578.511800
(N)TSCGECWOEU14/253×25 + 3×16/3E + 3×2.5ST + 6UELKON54.658.64100
(N)TSCGECWOEU14/253×35 + 3×25/3E + 3×2.5ST + 6UELKON57.161.14640
(N)TSCGECWOEU14/253×50 + 3×25/3E + 3×2.5ST + 6UELKON61655550
(N)TSCGECWOEU14/253×70 + 3×35/3E + 3×2.5ST + 6UELKON66.670.66860
(N)TSCGECWOEU14/253×95 + 3×50/3E + 3×2.5ST + 6UELKON70.274.28110
(N)TSCGECWOEU14/253×120 + 3×70/3E + 3×2.5ST + 6UELKON73.977.99450
(N)TSCGECWOEU18/303×25 + 3×16/3E + 3×2.5ST + 6UELKON58624490
(N)TSCGECWOEU18/303×35 + 3×25/3E + 3×2.5ST + 6UELKON60.764.75060
(N)TSCGECWOEU18/303×50 + 3×25/3E + 3×2.5ST + 6UELKON66.170.16220
(N)TSCGECWOEU18/303×70 + 3×35/3E + 3×2.5ST + 6UELKON70747330
(N)TSCGECWOEU18/303×95 + 3×50/3E + 3×2.5ST + 6UELKON73.977.98660
(N)TSCGECWOEU18/303×120 + 3×70/3E + 3×2.5ST + 6UELKON78.683.610250
(N)TSCGECWÖU3.6/63 x 25 + 3 x 16/3E + 3 x 2.5 ST + 6ÜL KON42.245.42770
(N)TSCGECWÖU3.6/63 x 35 + 3 x 25/3E + 3 x 2.5 ST + 6ÜL KON46.850.03200
(N)TSCGECWÖU3.6/63 x 50 + 3 x 25/3E + 3 x 2.5 ST + 6ÜL KON50.153.24040
(N)TSCGECWÖU3.6/63 x 70 + 3 x 35/3E + 3 x 2.5 ST + 6ÜL KON54.657.75035
(N)TSCGECWÖU3.6/63 x 95 + 3 x 50/3E + 3 x 2.5 ST + 6ÜL KON56.460.56270
(N)TSCGECWÖU3.6/63 x 120 + 3 x 70/3E + 3 x 2.5 ST + 6ÜL KON64.068.07400
(N)TSCGECWÖU6/103 x 25 + 3 x 16/3E + 3 x 2.5 ST + 6ÜL KON45.548.22975
(N)TSCGECWÖU6/103 x 35 + 3 x 25/3E + 3 x 2.5 ST + 6ÜL KON47.851.03420
(N)TSCGECWÖU6/103 x 50 + 3 x 25/3E + 3 x 2.5 ST + 6ÜL KON50.754.94260
(N)TSCGECWÖU6/103 x 70 + 3 x 35/3E + 3 x 2.5 ST + 6ÜL KON57.261.45270
(N)TSCGECWÖU6/103 x 95 + 3 x 50/3E + 3 x 2.5 ST + 6ÜL KON61.165.36540
(N)TSCGECWÖU6/103 x 120 + 3 x 70/3E + 3 x 2.5 ST + 6ÜL KON65.169.37840
(N)TSCGECWÖU12/203 x 25 + 3 x 16/3E + 3 x 2.5 ST + 6ÜL KON51.155.33600
(N)TSCGECWÖU12/203 x 35 + 3 x 25/3E + 3 x 2.5 ST + 6ÜL KON54.058.24140
(N)TSCGECWÖU12/203 x 50 + 3 x 25/3E + 3 x 2.5 ST + 6ÜL KON59.463.65030
(N)TSCGECWÖU12/203 x 70 + 3 x 35/3E + 3 x 2.5 ST + 6ÜL KON64.268.46200
(N)TSCGECWÖU12/203 x 95 + 3 x 50/3E + 3 x 2.5 ST + 6ÜL KON69.273.87520
(N)TSCGECWÖU12/203 x 120 + 3 x 70/3E + 3 x 2.5 ST + 6ÜL KON73.677.88740

How to specify the right TBM cable

Provide the exact variant spelling, rated voltage, power-core cross-section, protective-earth and control-core arrangement, monitoring interface, reel diameter, travel distance and speed, S-turn layout, expected tensile and torsional loads, installation temperature, cable length and quantity. State any exposure to water, oil, chemicals or abrasion so TEBAOFLEX can check the required construction rather than assume a performance level that has not been established for the selected build.

The two technical sheets use DIN VDE 0250-813 as a design reference. Referenced standards and tests do not, by themselves, establish third-party certification for every configuration. Request the applicable test evidence and certificate for the exact product offered.

Frequently asked selection questions

Are (N)TSCGECWOEU and (N)TSCGECWÖU interchangeable?

No. They are related TBM reeling constructions, but their published dimension schedules and moving-duty temperature limits differ. Specify the exact name and row from the relevant datasheet.

Does every voltage grade have a published size?

No. The available dimension rows depend on the source variant. For example, the (N)TSCGECWÖU schedule lists voltage grades beyond the 3.6/6, 6/10 and 12/20 kV rows shown here; request a drawing for an unlisted configuration.

What information is needed to select a TBM reeling cable?

Start with voltage, conductor size, load and protective-earth requirements. Then provide the reel and cable-path geometry, motion profile, environmental exposure and monitoring-circuit requirements. These determine whether a documented build is suitable or a project-specific configuration review is needed.

Technical datasheets

Request a configuration review

TEBAOFLEX can review the required voltage, conductor and monitoring arrangement, motion conditions and project quantity against the documented options. Final construction, tests, delivery and commercial terms are confirmed for the specific enquiry.

Send Your Requirements

Product Model

(N)TSCGECWOEU; (N)TSCGECWÖU

Product Type

Medium-voltage tunnel boring machine reeling cable

Rated Voltage

3.6/6 to 18/30 kV, variant-dependent

Core Configuration

Three power, three control, earth and monitoring

Outer Sheath

Red 5GM5 rubber

Temperature Range

−40 to +90 °C fixed; moving duty variant-dependent

Application

Reel-fed TBM and tunnel construction power supply with screened cores, control conductors and an overall monitoring conductor.

Conductor

Class 5 tinned copper

Insulation

EPR rubber with inner and outer semi-conductive layers