Home » Industrial Flexible & Special Cable Products » Type 245 Semiconductive Screened Cable (AS/NZS 1802) | 1.1/1.1 kV to 6.6/6.6 kV Longwall Shearer & 3-Pilot Mining Cable

Type 245 Semiconductive Screened Cable (AS/NZS 1802) | 1.1/1.1 kV to 6.6/6.6 kV Longwall Shearer & 3-Pilot Mining Cable

AS/NZS 1802 Type 245 semiconductive screened flexible rubber longwall shearer cable (1.1 kV, 3.3 kV, and 6.6 kV; 16–150 mm²) featuring fine 0.30–0.40 mm tinned copper stranding, three interstitial earth cores, and three central extensible pilots (28/0.25) for simultaneous earth-continuity monitoring and shearer control telemetry.

Standard & Sub-Types
AS/NZS 1802 (Type 245.1 / 245.3 / 245.6)
Rated Voltage Range
1.1/1.1 kV, 3.3/3.3 kV, 6.6/6.6 kV
Core & Multi-Pilot Design
3 Phase + 3 Interstitial Earths + 3 Central Pilots
Fine Shearer Stranding
133/0.40 up to 2146/0.30 Tinned Copper
Cradle / Reinforced Sheath
Semiconductive PCP + Open-Weave HD-85-PCP
Operating Temp & Flame
−25 °C to +90 °C | C1 Flame Retardant
Engineering Datasheet: AS/NZS 1802 Type 245 (PDF, 2 Pages)

Application & Operating Conditions

AS/NZS 1802 Type 245 is a semiconductive screened flexible rubber mining cable (1.1 kV to 6.6 kV, 16–150 mm²) engineered primarily for underground longwall shearers, continuous miners, and peripheral longwall face machinery requiring three central extensible pilots for simultaneous earth-continuity protection, remote stop/start control, and machine diagnostics.

Longwall Shearer Power & Telemetry

Three EPR-insulated central extensible pilots positioned along the neutral bending axis support earth-continuity relays plus two dedicated control or condition-monitoring channels along the armored face conveyor.

Continuous Miners & Face Peripherals

Fine 0.30 mm tinned copper stranding (703/0.30 on 50 mm² up to 2146/0.30 on 150 mm²) withstands continuous flexing on shearer haulage traverses, stage loaders, and crusher drives.

Cradle-Stabilized Wet Face Duty

A semiconductive PCP cradle separator and overall core filling lock core geometry beneath an open-weave reinforced HD-85-PCP sheath (with optional CPE/CSP sheathing for aggressive mine fluids).

Tight Bretby Cable-Chain Application? For 1.1 kV and 3.3 kV longwall shearer cable handler chains experiencing extreme tight-radius reverse bending (50–150 mm²), compare our specialized AS/NZS 1802 Type 245UF (Ultra-Flexible) shearer cable.

Cable Construction (AS/NZS 1802 Type 245)

Type 245 centers three extensible EPR-covered pilot cores inside a cushioned semiconductive PCP cradle, surrounded by three semiconductive-screened EPR phase cores, three interstitial earth conductors, open-weave reinforcement, and a heavy-duty PCP sheath.

Layer / ComponentMaterial & AS/NZS 1802 Specification
1. Phase ConductorsFlexible finely stranded tinned annealed copper, three phase cores (0.30–0.40 mm wires; up to 2,146 strands on 150 mm²)
2. Conductor ScreenExtruded semi-conductive compound for cables rated 3.3 kV (Type 245.3) and 6.6 kV (Type 245.6)
3. Insulation & ScreenR-EP-90 EPR thermosetting insulation enclosed in an extruded semi-conductive elastomer insulation screen
4. Three Central PilotsThree central extensible pilots laid at the cable center inside a semiconductive PCP cradle separator (each 28/0.25 mm tinned Cu with 0.8 mm EPR cover)
5. Interstitial Earths & FillThree semiconductive-PCP-covered flexible tinned copper earth cores (69/0.25 to 375/0.30) + semiconductive PCP overall core filling & covering
6. Reinforcement & SheathOpen-weave reinforcing yarns embedded beneath a black heavy-duty HD-85-PCP outer sheath (CPE/CSP sheath available on request)
Cross-section diagram of TEBAOFLEX AS/NZS 1802 Type 245 longwall shearer mining cable with three central extensible pilots

Type 245 Cross-Section Geometry: Note the distinctive trefoil bundle of three central extensible pilots cushioned inside the grey semiconductive PCP cradle between the three phase cores.

Red / White / Blue Phases 3 Earths 3 Central Pilots

Technical Characteristics

Manufactured to AS/NZS 1802 across 1.1 kV, 3.3 kV, and 6.6 kV, Type 245 longwall shearer cables provide +90 °C continuous thermal rating, −25 °C cold bend capability, and C1 vertical flame retardancy.

ParameterAS/NZS 1802 Rated Value
Manufacturing StandardAS/NZS 1802 (Electric cables — Reeling and trailing — For underground coal mining applications)
Voltage Grades & Sub-TypesType 245.1 (1.1/1.1 kV) | Type 245.3 (3.3/3.3 kV) | Type 245.6 (6.6/6.6 kV)
Phase Cross-Section Range16–150 mm² (1.1 kV) | 25–150 mm² (3.3 kV) | 50–150 mm² (6.6 kV)
Central Pilot Configuration3 × extensible central pilots (28/0.25 mm tinned copper, 0.8 mm EPR insulation)
Max. Continuous Conductor Temp.+90 °C
Minimum Installation Temperature−25 °C
Primary Service ConditionsLongwall shearer, continuous miner, and peripheral longwall face cable service
Sheath Colour & Flame RatingBlack HD-85-PCP standard (custom colours / CPE / CSP on request) | C1 flame performance

Specification & Stranding Data (20 Standard Sizes)

Dimensional, wire stranding, insulation/sheath wall, and mass specifications for AS/NZS 1802 Type 245.1 (1.1 kV), Type 245.3 (3.3 kV), and Type 245.6 (6.6 kV) longwall shearer cables.

Sub-TypeVoltageArea RangePhase StrandEPR Insul.OD RangeMass (kg/100m)
Type 245.11.1/1.1 kV16–150 mm² (8)133/0.40 – 2146/0.301.6–2.3 mm42.6–70.5 mm235–915
Type 245.33.3/3.3 kV25–150 mm² (7)259/0.36 – 2146/0.303.0 mm51.1–75.2 mm338–1028
Type 245.66.6/6.6 kV50–150 mm² (5)703/0.30 – 2146/0.305.0 mm67.2–85.8 mm635–1210
Type 245.1 — Rated Voltage: 1.1/1.1 kV (16 mm² to 150 mm² | 8 Sizes)
Area (mm²)Phase Strand (No./mm)Insul. (mm)Earth Strand (No./mm)Screen / Cover (mm)Pilot Strand (3×)Pilot Cover (mm)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
3 × 16133 / 0.402.069 / 0.251.828 / 0.250.84.142.6235
3 × 25259 / 0.361.691 / 0.251.828 / 0.250.84.243.4269
3 × 35287 / 0.401.6140 / 0.251.428 / 0.250.84.445.6315
3 × 50703 / 0.301.7120 / 0.301.028 / 0.250.84.848.4390
3 × 70988 / 0.301.8180 / 0.301.028 / 0.250.85.153.9501
3 × 951332 / 0.302.0150 / 0.301.028 / 0.250.85.660.4630
3 × 1201702 / 0.302.1195 / 0.301.228 / 0.250.86.065.5765
3 × 1502146 / 0.302.3235 / 0.301.228 / 0.250.86.370.5915
Type 245.3 — Rated Voltage: 3.3/3.3 kV (25 mm² to 150 mm² | 7 Sizes)
Area (mm²)Phase Strand (No./mm)Insul. (mm)Earth Strand (No./mm)Screen / Cover (mm)Pilot Strand (3×)Pilot Cover (mm)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
3 × 25259 / 0.363.091 / 0.251.528 / 0.250.85.251.1338
3 × 35287 / 0.403.0140 / 0.251.028 / 0.250.85.454.5398
3 × 50703 / 0.303.0120 / 0.301.028 / 0.250.85.756.8490
3 × 70988 / 0.303.0180 / 0.301.228 / 0.250.86.061.2592
3 × 951332 / 0.303.0235 / 0.301.228 / 0.250.86.466.6739
3 × 1201702 / 0.303.0300 / 0.301.228 / 0.250.86.771.0870
3 × 1502146 / 0.303.0375 / 0.301.228 / 0.250.87.075.21028
Type 245.6 — Rated Voltage: 6.6/6.6 kV (50 mm² to 150 mm² | 5 Sizes)
Area (mm²)Phase Strand (No./mm)Insul. (mm)Earth Strand (No./mm)Screen / Cover (mm)Pilot Strand (3×)Pilot Cover (mm)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
3 × 50703 / 0.305.0120 / 0.301.428 / 0.250.86.767.2635
3 × 70988 / 0.305.0180 / 0.301.428 / 0.250.87.071.7755
3 × 951332 / 0.305.0235 / 0.301.428 / 0.250.87.477.1905
3 × 1201702 / 0.305.0300 / 0.301.428 / 0.250.87.781.31050
3 × 1502146 / 0.305.0375 / 0.301.428 / 0.250.88.085.81210

Selection: Type 245 vs. Type 245UF vs. Type 241

Selecting between AS/NZS 1802 semiconductive screened cables depends on pilot-core count (3 central pilots vs. 1 central pilot), system voltage (up to 6.6 kV vs. 3.3 kV), and shearer cable-chain bend radius.

Cable ModelKey Architecture & Best-Fit Longwall Duty
Type 245 (This Product)3 central extensible pilots, 16–150 mm², rated across 1.1 kV, 3.3 kV, and 6.6 kV. Ideal for high-voltage 6.6 kV shearers, continuous miners, and peripheral longwall drives needing multi-channel control/monitoring.
Type 245UF (Ultra-Flexible)Type 245UF covers 50–150 mm² at 1.1 kV & 3.3 kV with ultra-flexible lay geometry and ≤3 Ω/100m central pilots specifically optimized for tight articulated Bretby shearer cable handler chains.
Type 241 / Type 241SFWhere only a single central extensible pilot is required (up to 11/11 kV and 300 mm²), specify Type 241 or narrow-loop monorail Type 241SF.

Frequently Asked Questions (FAQ)

Technical answers covering Type 245 three-pilot geometry, 6.6 kV longwall shearer supply, and outer sheath compounds.

Why are the three pilots placed in the center of Type 245 rather than in the outer interstices?

On a reciprocating longwall shearer, the three outer interstices are occupied by large semiconductive-covered earth conductors in continuous fault-sensing contact with the phase screens. Grouping the three extensible control/monitoring pilots along the neutral center axis inside a semiconductive PCP cradle shields them from external crush loads and minimizes tensile strain during cyclic bending.

Does Type 245 support 6.6 kV high-output longwall shearers?

Yes. Type 245.6 (6.6/6.6 kV) is manufactured from 50 mm² to 150 mm² with extruded conductor screens, 5.0 mm R-EP-90 EPR insulation, semiconductive elastomer screens, and 6.7–8.0 mm reinforced HD-85-PCP sheathing for high-voltage longwall faces.

Can TEBAOFLEX manufacture Type 245 with high-visibility coloured or CPE/CSP sheaths?

Yes. Black HD-85-PCP is supplied as standard, and we custom-extrude CPE, CSP, or mine-specified visibility stripes/colours cut to exact longwall face lengths on export drums.

Request a Factory Quote for AS/NZS 1802 Type 245 Shearer Cables

Share your longwall face voltage (1.1 kV, 3.3 kV, or 6.6 kV), cross-section (16–150 mm²), and required cut length with TEBAOFLEX engineering sales.

Explore All Mining & Tunneling Cables
Product Model

Type 245 (Sub-Types 245.1, 245.3, 245.6)

Standard

AS/NZS 1802

Voltage Rating

1.1/1.1 kV (Type 245.1), 3.3/3.3 kV (Type 245.3), 6.6/6.6 kV (Type 245.6)

Nominal Conductor Area

16–150 mm² (1.1 kV), 25–150 mm² (3.3 kV), 50–150 mm² (6.6 kV)

Conductor Stranding

Extra-flexible tinned annealed copper (133/0.40 up to 2146/0.30)

Insulation & Screens

R-EP-90 EPR insulation + semiconductive elastomer screen (conductor screen >=3.3 kV)

Cradle & Core Screen

Semiconductive PCP cradle separator + semiconductive PCP overall core filling & covering

Central Pilot Conductors

3 central extensible EPR-covered tinned copper pilots (28/0.25 each, 0.8 mm cover)

Interstitial Earth Cores

3 semiconductive-PCP-covered flexible tinned copper earth cores (69/0.25 to 375/0.30)

Outer Sheath & Reinforcement

Open-weave reinforcing braid under heavy-duty black HD-85-PCP sheath (CPE/CSP optional)

Operating Temperature & Flame

−25 °C min. installation to +90 °C max. continuous conductor, C1 flame performance