Ground-check anti-torsion reeling cable
A dedicated ground-check conductor distinguishes this yellow cable from the standard anti-torsion version. The phase, two earth and one ground-check conductors support power delivery and earth-continuity monitoring on heavy mobile mining equipment.
Where it is used
Trailing and reel-fed power to draglines, shovels, dredges and drills with a compatible ground-check monitoring circuit.
Cable construction
| Component | Specification |
|---|---|
| Phase conductor | Class 5 tinned copper |
| Earth / ground check | Two copper earth conductors plus one copper ground-check conductor |
| Insulation | Rubber compound with semi-conductive layers from 3.6/6 kV |
| Anti-torsion layer | Polyester braid between inner and outer sheath |
| Outer sheath | Yellow abrasion-resistant rubber compound |

Operating and selection data
| Parameter | Documented value / selection note |
|---|---|
| Rated voltage | 1.8/3, 3.6/6, 6/10, 8.7/15 and 12/20 kV |
| Fixed / flexed temperature | −40 to +90 °C / −25 to +90 °C |
| Minimum bending radius | 6 × OD fixed; 10 × OD flexed |
Dimensions by voltage and configuration
Nominal values from the company datasheet. Dimensions and weights may vary within manufacturing tolerances; electrical ratings depend on the stated installation conditions.
| Voltage (kV) | Core arrangement | Phase (mm²) | Earth (mm²) | Control / GC (mm²) | Conductor Ø (mm) | OD min (mm) | OD max (mm) | Tensile (N) | Weight (kg/km) |
|---|---|---|---|---|---|---|---|---|---|
| 1.8/3 | 3+2+1 | 25 | 25/2 | 10 | 6.8 | 38.2 | 42.3 | 1125 | 2530 |
| 1.8/3 | 3+2+1 | 35 | 25/2 | 10 | 7.8 | 39.7 | 44 | 1575 | 2930 |
| 1.8/3 | 3+2+1 | 50 | 25/2 | 10 | 9.4 | 42.7 | 47.2 | 2250 | 3540 |
| 1.8/3 | 3+2+1 | 70 | 35/2 | 10 | 11.2 | 48.1 | 53 | 3150 | 4730 |
| 1.8/3 | 3+2+1 | 95 | 50/2 | 10 | 12.7 | 53 | 58.3 | 4257 | 5930 |
| 1.8/3 | 3+2+1 | 120 | 70/2 | 10 | 14.4 | 57.4 | 63.1 | 5400 | 7270 |
| 1.8/3 | 3+2+1 | 150 | 70/2 | 10 | 16.3 | 63.8 | 70 | 6750 | 8920 |
| 1.8/3 | 3+2+1 | 185 | 95/2 | 10 | 17.6 | 65.6 | 71.9 | 8325 | 10220 |
| 3.6/6 | 3+2+1 | 25 | 25/2 | 10 | 6.8 | 45.4 | 50.1 | 1125 | 3300 |
| 3.6/6 | 3+2+1 | 35 | 25/2 | 10 | 7.8 | 46.7 | 51.5 | 1575 | 3710 |
| 3.6/6 | 3+2+1 | 50 | 25/2 | 10 | 9.4 | 51.5 | 56.7 | 2250 | 4600 |
| 3.6/6 | 3+2+1 | 70 | 35/2 | 10 | 11.2 | 55.2 | 60.7 | 3150 | 5710 |
| 3.6/6 | 3+2+1 | 95 | 50/2 | 10 | 12.7 | 58.9 | 64.8 | 4257 | 6820 |
| 3.6/6 | 3+2+1 | 120 | 70/2 | 10 | 14.4 | 65.1 | 71.4 | 5400 | 8540 |
| 3.6/6 | 3+2+1 | 150 | 70/2 | 10 | 16.3 | 69.9 | 76.3 | 6750 | 9890 |
| 6/10 | 3+2+1 | 25 | 25/2 | 10 | 6.8 | 48.1 | 53 | 1125 | 3640 |
| 6/10 | 3+2+1 | 35 | 25/2 | 10 | 7.8 | 49.5 | 54.6 | 1575 | 4070 |
| 6/10 | 3+2+1 | 50 | 25/2 | 10 | 9.4 | 54.2 | 59.7 | 2250 | 4980 |
| 6/10 | 3+2+1 | 70 | 35/2 | 10 | 11.2 | 57.9 | 63.6 | 3150 | 6070 |
| 6/10 | 3+2+1 | 95 | 50/2 | 10 | 12.7 | 61.6 | 67.7 | 4257 | 7280 |
| 8.7/15 | 3+2+1 | 25 | 25/2 | 10 | 6.8 | 53.9 | 59.3 | 1125 | 4490 |
| 8.7/15 | 3+2+1 | 35 | 25/2 | 10 | 7.8 | 55.3 | 60.8 | 1575 | 4920 |
| 8.7/15 | 3+2+1 | 50 | 25/2 | 10 | 9.4 | 58.5 | 64.2 | 2250 | 5700 |
| 8.7/15 | 3+2+1 | 70 | 35/2 | 10 | 11.2 | 64.2 | 70.5 | 3150 | 7200 |
| 8.7/15 | 3+2+1 | 95 | 50/2 | 10 | 12.7 | 67.9 | 74.4 | 4257 | 8480 |
| 12/20 | 3+2+1 | 25 | 25/2 | 10 | 6.8 | 58.2 | 63.9 | 1125 | 5110 |
| 12/20 | 3+2+1 | 35 | 25/2 | 10 | 7.8 | 59.8 | 65.7 | 1575 | 5580 |
| 12/20 | 3+2+1 | 50 | 25/2 | 10 | 9.4 | 64.6 | 70.9 | 2250 | 6550 |
| 12/20 | 3+2+1 | 70 | 35/2 | 10 | 11.2 | 68.3 | 74.8 | 3150 | 7800 |
Installation limits
Ground-check conductor size and monitoring compatibility must match the equipment circuit; the 1.8/3 kV construction is not interchangeable with higher-voltage insulation systems.
Technical datasheets
- (N)TSCGECEWÖU-GCC Ground-Check Reeling Cable | 1.8/3–6/10 kV Technical Datasheet
- (N)TSCGECEWÖU-GCC Ground-Check Reeling Cable | 8.7/15–12/20 kV Technical Datasheet
Standards named in the datasheets are design or test references; request the applicable certificate and test evidence for the exact product configuration.
Request a configuration review
Send the voltage, conductor size, core arrangement, moving or fixed duty, bend radius, environment, required length and quantity to TEBAOFLEX. We will confirm the construction and commercial details for the project.