GP 400 SC / QF PUR 400 Hz Aircraft Ground Power Cable covers single-core and quad-flex cable constructions for flexible ground power connections, mobile ground power units, PIT systems, and reeling interfaces.
Applications
Choose the SC design where a single power element with integrated control cores is required. Choose the QF construction where four marked power elements are needed. Both are designed for flexible routing between equipment, sleeves, plugs, and reeling systems.
Construction and Performance
- Tinned fine-stranded copper conductors to IEC 60228 Class 5.
- Red, black, green, and yellow control-core identification; red power cores.
- Red PUR inner sheath and yellow abrasion-resistant PUR outer sheath.
- Low-capacitance insulation; QF construction uses open stranding.
Technical Parameters
| Parameter | Specification |
|---|---|
| Nominal voltage | Uo/U 115/200 V |
| Maximum permissible operating voltage | Uo/U 0.6/1 kV |
| Test voltage | 4,000 V AC, 50 Hz core/core |
| Temperature range | Fixed −50 to +90 °C; flexible −40 to +90 °C; +110 °C limited to 7,500 h |
| Minimum bending radius | 4 × D fixed; 6 × D flexible |
| QF reference constructions | 4 × (35–95 mm² + 4–6 × 1.0 mm²) |
| QF outer diameter range | Approx. 38.6–47.3 mm, by configuration |
Selection Support
Provide the required SC or QF construction, conductor size, connector layout, and installation conditions. Request a Quote