Home » Industrial Flexible & Special Cable Products » H07RN-F 450/750V Heavy-Duty Flexible Rubber Power Cable | EN 50525-2-21 / IEC 60245-4

H07RN-F 450/750V Heavy-Duty Flexible Rubber Power Cable | EN 50525-2-21 / IEC 60245-4

TEBAOFLEX H07RN-F is a harmonized 450/750 V heavy-duty flexible EPR/PCP rubber power cable engineered to EN 50525-2-21 (DIN VDE 0285-525-2-21 / IEC 60245-4) for mobile generators, construction distribution skids, industrial machinery, stage power, and outdoor wet/dry worksites.

Rated Voltage450/750 V (0.6/1 kV Fixed Prot.)
Design StandardsEN 50525-2-21 / IEC 60245-4
ConductorClass 5 Flexible Copper (IEC 60228)
Insulation & Outer SheathEI4 EPR Rubber + EM2 Black PCP
Operating Temperature-25°C to +60°C Flex (-40°C Fixed)
Core & Size Range1 to 24+ Cores | 1.5 – 630 mm²

Send your core count (1×, 3G, 4G, 5G, or multi-core control), conductor cross-section, and drum length to Request H07RN-F Factory Datasheet & Quote.

TEBAOFLEX H07RN-F 450/750V Heavy-Duty Flexible Rubber Cable is manufactured in accordance with harmonized European standard EN 50525-2-21 (DIN VDE 0285-525-2-21 / IEC 60245-4 66) for medium-to-high mechanical stress in dry, damp, wet, and outdoor industrial service. Built with IEC 60228 Class 5 fine-stranded copper conductors, cross-linked EI4 EPR core insulation, and a rugged oil-, ozone-, and flame-resistant black EM2 polychloroprene (PCP) rubber outer sheath, it supports both 450/750 V portable feeders and 0.6/1 kV fixed protected installations.

1. Industrial Application Scope & Harmonized H07 Rubber Family Comparison

Where PVC site cables crack in winter cold or split under workshop impact and oil splash, H07RN-F remains supple and abrasion-resistant across repeated coiling, dragging, and outdoor weather exposure:

  • Rental Generators, Load Banks & Temporary Site Power: Single-core (1×35 to 1×630 mm² with Powerlock/camlock terminations) and 5-core three-phase distribution feeders (5G2.5 to 5G95 mm²) for construction sites, shipyards, and outdoor events.
  • Industrial Machinery, Workshops & Agricultural Equipment: Flexible power supply leads for mobile compressors, welding sets, woodworking/metalworking machines, heating plates, and portable inspection lamps.
  • Fixed Protected Crane, Hoist & Switchgear Wiring (Up to 0.6/1 kV): Vibration-resistant motor and busbar jumpers in conduits, plaster, or enclosed crane girders per HD 516 / DIN VDE 0298-300.

Explore related rubber cable options across our industrial and control cable range and flexible rubber cable catalog:

Harmonized H07 Rubber GradeVoltage RatingInsulation / SheathPrimary Engineering Distinction
H07RN-F (This Page)450/750 V (0.6/1 kV Fixed)EI4 EPR / EM2 PCPGeneral heavy-duty portable, outdoor, oil-splash & industrial power
H07RN8-F Submersible Rubber Cable450/750 VEI4 EPR / AD8 EM2 PCPAD8 continuous shallow-water immersion up to 10 m for submersible pumps
H07BN4-F / H07 Series Overview450/750 VEI7 EPR / EM7 ElastomerExtended +90°C continuous conductor thermal rating (H07BN4-F)

2. Concentric 4-Layer Cable Construction (EN 50525-2-21)

Matching the multi-core cross-section photograph above, TEBAOFLEX H07RN-F is built from electrolytic Class 5 copper outward with vulcanized thermoset elastomers that will not melt under overload or weld-splatter contact:

1. Class 5 Flexible Copper Conductor
Fine-stranded annealed bare copper per IEC 60228 / EN 60228 Class 5 (Class 5 tinned copper optional on request for marine dockside or sulfide-rich atmospheres), wrapped with a clean-strip separator tape on medium/large cross-sections.
2. EI4 EPR Rubber Core Insulation
Cross-linked ethylene propylene rubber compound Type EI4 per EN 50363-1, providing high dielectric strength, ozone immunity, and cold-bend elasticity without thermoplastic softening.
3. HD 308 S2 Core Identification
Color-coded per CENELEC HD 308 S2 up to 5 cores (G = including Green/Yellow protective earth, e.g., 5G: Green/Yellow, Blue, Brown, Black, Grey; X = without Green/Yellow); 6 cores and above use black cores with sequential white numbers plus Green/Yellow PE, laid up with central textile/elastomer filler where required for circularity.
4. EM2 Polychloroprene Outer Sheath
Vulcanized heavy-duty polychloroprene (PCP / chloroprene rubber) compound Type EM2 per EN 50363-2-1 in matte black, engineered for tear, cut, mineral-oil (EN 60811-404), UV, weather, and flame propagation resistance (IEC/EN 60332-1-2).

3. Electrical, Thermal & Mechanical Operating Parameters

ParameterSpecification ValueStandard / Engineering Condition
Nominal Voltage (U0/U)450/750 V ACStandard portable, free-flexing & temporary distribution service
Protected Fixed VoltageUp to 0.6/1 kV (600/1000 V AC)Fixed & mechanically protected routing in conduits/cranes per HD 516
Routine AC Test Voltage2,500 V AC (50 Hz, 5 min)EN 50525-2-21 / IEC 60245-4 factory dielectric test
Ambient Temperature Range-25°C to +60°C flexing | -40°C fixedMax. conductor temp +60°C (IEC 60245-4) / up to +85°C–90°C on EN 50525 review; 200°C short-circuit
Minimum Bending Radius4 × D (fixed) | 6 × D to 8 × D (flexing)HD 516 / DIN VDE 0298-300 (D = overall cable outer diameter)
Max. Static Tensile Load15 N/mm² × total copper cross-sectionDo not exceed during conduit pulling or catenary suspension
Flame, Oil & Weather RatingIEC/EN 60332-1-2 / EN 60811-404Self-extinguishing, mineral-oil & grease resistant, UV/ozone stable

Submersible vs. Dynamic Reeling Selection Boundary: Standard H07RN-F handles rain, wet ground, and splash exposure, but is not intended for permanent underwater pump immersion (specify H07RN8-F AD8 instead) or high-speed motorized crane/mining cable reels (specify braided PUR or VDE 0250-812 NSSHÖU reeling cables).

4. Representative H07RN-F Dimension, Copper Index & Weight Schedule

Nominal diameter windows and weights below cover high-demand single-core generator leads and 3-core to 5-core three-phase distribution sizes per EN 50525-2-21. Full schedules from 1×1.5 to 1×630 mm² and 2×1.0 to 24G2.5 mm² are available on request (all part designations use clean standard model codes):

Part DesignationCores × Size (mm²)Nom. EI4 Wall (mm)Nom. EM2 Sheath (mm)Outer Ø Min – Max (mm)Copper Index (kg/km)Approx. Weight (kg/km)
H07RN-F-1X161 × 161.21.910.7 – 13.8154245
H07RN-F-1X351 × 351.42.214.3 – 17.9336470
H07RN-F-1X701 × 701.62.618.6 – 23.3672885
H07RN-F-1X1201 × 1201.83.022.8 – 28.61,1521,430
H07RN-F-1X2401 × 2402.23.630.6 – 38.32,3042,760
H07RN-F-3G1.53G1.50.81.69.2 – 11.943135
H07RN-F-3G2.53G2.50.91.810.9 – 14.072195
H07RN-F-4G2.54G2.50.91.912.1 – 15.496245
H07RN-F-4G64G61.02.315.7 – 20.0230485
H07RN-F-5G2.55G2.50.92.013.3 – 17.0120295
H07RN-F-5G65G61.02.517.5 – 22.2288605
H07RN-F-5G165G161.23.226.4 – 33.37681,380
H07RN-F-5G355G351.43.835.2 – 44.21,6802,690
H07RN-F-5G705G701.64.846.8 – 58.63,3605,080

5. Frequently Asked Engineering Questions & Custom RFQ

What do the harmonized designation codes in H07RN-F stand for?

Under CENELEC HD 361 / EN 50525 coding, H denotes a harmonized standard, 07 specifies a 450/750 V nominal rating, R indicates cross-linked EPR rubber core insulation (EI4), N denotes a heavy-duty polychloroprene (PCP, EM2) outer sheath, and -F specifies an IEC 60228 Class 5 flexible fine-stranded copper conductor.

Can H07RN-F cable be operated at 0.6/1 kV (600/1000 V)?

Portable and free-flexing H07RN-F installations are rated 450/750 V AC. Under HD 516 / DIN VDE 0298-300 rules, H07RN-F may be operated up to 0.6/1 kV AC when installed in fixed, mechanically protected routing such as conduits, switchgear cabinets, or crane hoist motors.

What is the difference between H07RN-F and H07RN8-F rubber cables?

H07RN-F covers indoor, outdoor, damp, and splash worksite duty, whereas H07RN8-F uses an AD8 water-resistant compound tested per EN 50525-2-21 for continuous shallow-water immersion up to 10 m on submersible pumps.

Are TEBAOFLEX H07RN-F conductors bare copper or tinned copper?

Standard H07RN-F uses IEC 60228 Class 5 fine-stranded annealed bare copper conductors, matching the cross-section photo above. Class 5 tinned copper conductors can be manufactured to order for marine shore-power or corrosive chemical plants.

What is the minimum bending radius for H07RN-F?

Per HD 516 / DIN VDE 0298-300, minimum bending radius is 4 × D for fixed protected installations and 6 × D to 8 × D for flexible mobile handling (where D is finished cable outer diameter).

What sizes and core counts can TEBAOFLEX supply in H07RN-F?

TEBAOFLEX supplies single-core 1×1.5 mm² up to 1×630 mm², 2-core to 5-core power cables (3G1.5 to 5G300 mm²), and multi-core control builds from 7G1.5 up to 24G2.5 mm². Submit your core count, cross-section, drum length, and destination port for quotation.

Specify Your H07RN-F 450/750V Heavy-Duty Rubber Cable Order

Share your core count and cross-section (1×16–630 mm² or 3G–24G multi-core), bare or tinned copper preference, drum or coil lengths, and destination port. TEBAOFLEX returns a full EN 50525-2-21 datasheet and factory quotation within 24 hours.

Request H07RN-F Factory Quote
Brand

TEBAOFLEX

Model

H07RN-F (Harmonized code; 60245 IEC 66)

Standard Reference

EN 50525-2-21; DIN VDE 0285-525-2-21; IEC 60245-4

Voltage Rating

450/750 V AC (0.6/1 kV fixed protected per HD 516; 2,500 V AC test)

Conductor

Class 5 flexible fine-stranded bare copper per IEC 60228 (tinned optional)

Core Insulation

EI4 cross-linked ethylene propylene rubber (EPR)

Core Identification

HD 308 S2 color code (up to 5 cores, G = with G/Y PE) or black white-numbered (≥6 cores)

Outer Sheath

EM2 heavy-duty polychloroprene (PCP) rubber, black

Temperature Rating

-25°C to +60°C flexing / -40°C fixed (up to +85°C/+90°C max conductor temp on review)

Flame & Oil Resistance

IEC/EN 60332-1-2 flame retardant; EN 60811-404 oil, ozone & UV resistant

Core & Size Range

1-core (1.5–630 mm²), 2 to 5-core (1.0–300 mm²) & multi-core control (7–24+ cores)

Typical Applications

Portable generators, site power distribution, mobile machinery, stage/events & workshops