The 8.18 mm Mono Conductor Wireline Cable is an armored electrical cable for downhole logging, intervention, and well-service applications. Its construction combines a stranded copper conductor, insulation, and two mechanical armor layers to carry an electrical signal while supporting controlled deployment in the well. TEBAOFLEX can review the required load, sheave diameter, temperature, fluid exposure, and length before configuration selection.
Key Features
- Armored mono conductor construction for electrical continuity and mechanical support.
- Specified voltage, resistance, and tensile data for the documented configuration.
- Multiple insulation options where stated in the technical data, allowing selection by temperature requirement.
- Suitable for controlled wireline deployment where the selected load and sheave arrangement remain within the documented limits.
Downhole Application

Wireline systems are used to lower and retrieve downhole tools while providing a reliable electrical path. Installation should follow the selected cable’s documented load limits, bend guidance, and environmental requirements.
Technical Parameters
| Parameter | Specification |
|---|---|
| Center conductor | 15 AWG, 19 x 0.0142 in; 0.071 in / 1.803 mm nominal diameter |
| Insulation outside diameter | 0.155 in / 3.937 mm |
| Inner armor layer | 12 galvanized steel wires x 0.0445 in; 0.233 in / 5.918 mm layer OD |
| Outer armor layer | 18 galvanized steel wires x 0.0445 in; 0.322 in / 8.179 mm layer OD |
| Rated voltage | 1500 VDC |
| DC conductor resistance at 20 °C | 2.8 Ω/kft / 9.2 Ω/km |
| DC armor resistance at 20 °C | 2.1 Ω/kft / 6.9 Ω/km |
| Minimum insulation resistance | 1500 MΩ·kft / 457 MΩ·km |
| Breaking strength, fixed ends | 11,300 lb / 5,125 kg |
| Maximum working load | 6,780 lb / 3,075 kg |
| Suggested minimum sheave diameter | 18 in / 457 mm |
| Outside diameter tolerance | +0.005 / -0.002 in; +0.127 / -0.051 mm |
| Stretch coefficient | 1.2 ft/kft/klb / 1.35 m/km/5 kN |
Configuration and Insulation Options
| Insulation type | Maximum temperature | Capacitance | Weight in air / water |
|---|---|---|---|
| Polypropylene | 300 °F / 149 °C | 46 pF/ft / 151 pF/m | 280 / 235 kg/km |
| FEP/ETFE | 500 °F / 260 °C | 48 pF/ft / 159 pF/m | 287 / 244 kg/km |
| PFA | 550 °F / 288 °C | 45 pF/ft / 148 pF/m | 292 / 247 kg/km |
| Q600 | 600 °F / 315 °C | 45 pF/ft / 148 pF/m | 292 / 247 kg/km |
Alternative corrosion-resistant alloy armor constructions are also listed in the supplied data. Confirm the selected armor alloy, load requirement, fluid exposure, and insulation system before ordering.
Selection Guidance
Match the exact conductor, armor material, insulation system, working load, sheave diameter, temperature, and well environment to the project requirement. The listed values are configuration-specific; confirm the final construction before purchasing.
Request a Quote
Request a quote with the required length, operating conditions, load, temperature range, and target configuration.