6.55 mm Mono Conductor Wireline Cable

6.55 mm mono conductor wireline cable with a 16 AWG center conductor and 12 inner / 18 outer armor wire construction for downhole operations.

The 6.55 mm mono conductor wireline cable is an armored downhole cable for logging, intervention, and other well-service operations that require an electrical conductor and high tensile strength in one compact construction. Its 16 AWG stranded conductor sits inside insulation, a 12-wire inner armor layer, and an 18-wire outer armor layer. TEBAOFLEX can support configuration review for the operating environment and insulation temperature requirement.

Key Features

  • 16 AWG stranded center conductor with a 1.499 mm nominal conductor diameter.
  • Two-layer steel armor construction with 12 inner wires and 18 outer wires, each specified at 0.0358 in.
  • 1200 VDC rating and 457 MΩ·km minimum insulation resistance in the conventional construction data.
  • 6.55 mm nominal outside diameter for compact handling on suitable downhole sheaves.
  • Multiple insulation options with stated temperature ratings from 149 °C to 315 °C, depending on selected construction.

Applications

This mono conductor wireline cable is suited to downhole operations where a single electrical path and armored mechanical support are required. Confirm the selected insulation system, operational temperature, loading, fluid exposure, and sheave arrangement before specification.

6.55 mm mono conductor wireline cable deployed from a logging winch to an oil and gas wellhead
A 6.55 mm mono conductor armored wireline cable is deployed from a wireline winch to a wellhead during a downhole operation.

Documented Construction Specifications

The referenced construction uses a 16 AWG, 19-strand center conductor with a 1.499 mm nominal conductor diameter. Its insulation outside diameter is 3.124 mm, followed by 12 inner armor wires and 18 outer armor wires, each specified at 0.0358 in. The conventional configuration is rated 1200 VDC and has a 6.55 mm nominal outside diameter.

Technical Parameters

ParameterSpecification
Cable construction1/4 in (6.55 mm) mono conductor cable; 12 inner / 18 outer wire construction
Center conductor16 AWG, 19 x 0.0119 in stranded conductor
Conductor diameter0.059 in / 1.499 mm
Insulation outside diameter0.123 in / 3.124 mm
Inner armor12 wires x 0.0358 in; 0.186 in / 4.724 mm layer OD
Outer armor18 wires x 0.0358 in; 0.258 in / 6.553 mm layer OD
Rated voltage1200 VDC
DC conductor resistance at 20 °C13.1 Ω/km (conventional construction)
DC armor resistance at 20 °C9.84 Ω/km (conventional construction)
Minimum insulation resistance457 MΩ·km
Breaking strength, ends fixed3175 kg / 7000 lb (conventional construction)
Maximum working load1905 kg / 4200 lb (conventional construction)
Suggested minimum sheave diameter356 mm / 14 in
Outside diameter tolerance6.55 mm (+0.127 / -0.051 mm)
Insulation optionsPolypropylene, ETFE, FEP/ETFE, PFA, or Q600
Temperature range by insulation option149 °C to 315 °C

Selection Guidance

Choose the insulation option according to the required temperature range and operating environment. Provide the intended working load, sheave size, well conditions, and required length so the TEBAOFLEX technical team can review the appropriate construction.

Request a Quote

Request a quote with the selected insulation type, working load, operating temperature, length, and application details.

Product Model

6.55 mm Mono Conductor Wireline Cable

Product Type

Mono conductor armored wireline cable

Conductor

16 AWG, 19 x 0.0119 in stranded conductor

Conductor Diameter

1.499 mm

Insulation OD

3.124 mm

Inner Armor

12 wires x 0.0358 in

Outer Armor

18 wires x 0.0358 in

Overall Diameter

6.55 mm (+0.127 / -0.051 mm)

Rated Voltage

1200 VDC

Suggested Minimum Sheave Diameter

356 mm

Temperature Rating

149 °C to 315 °C, depending on insulation type