The 6.55 mm mono conductor wireline cable is an armored downhole cable for logging, intervention, and other well-service operations that require an electrical conductor and high tensile strength in one compact construction. Its 16 AWG stranded conductor sits inside insulation, a 12-wire inner armor layer, and an 18-wire outer armor layer. TEBAOFLEX can support configuration review for the operating environment and insulation temperature requirement.
Key Features
- 16 AWG stranded center conductor with a 1.499 mm nominal conductor diameter.
- Two-layer steel armor construction with 12 inner wires and 18 outer wires, each specified at 0.0358 in.
- 1200 VDC rating and 457 MΩ·km minimum insulation resistance in the conventional construction data.
- 6.55 mm nominal outside diameter for compact handling on suitable downhole sheaves.
- Multiple insulation options with stated temperature ratings from 149 °C to 315 °C, depending on selected construction.
Applications
This mono conductor wireline cable is suited to downhole operations where a single electrical path and armored mechanical support are required. Confirm the selected insulation system, operational temperature, loading, fluid exposure, and sheave arrangement before specification.

Documented Construction Specifications
The referenced construction uses a 16 AWG, 19-strand center conductor with a 1.499 mm nominal conductor diameter. Its insulation outside diameter is 3.124 mm, followed by 12 inner armor wires and 18 outer armor wires, each specified at 0.0358 in. The conventional configuration is rated 1200 VDC and has a 6.55 mm nominal outside diameter.
Technical Parameters
| Parameter | Specification |
|---|---|
| Cable construction | 1/4 in (6.55 mm) mono conductor cable; 12 inner / 18 outer wire construction |
| Center conductor | 16 AWG, 19 x 0.0119 in stranded conductor |
| Conductor diameter | 0.059 in / 1.499 mm |
| Insulation outside diameter | 0.123 in / 3.124 mm |
| Inner armor | 12 wires x 0.0358 in; 0.186 in / 4.724 mm layer OD |
| Outer armor | 18 wires x 0.0358 in; 0.258 in / 6.553 mm layer OD |
| Rated voltage | 1200 VDC |
| DC conductor resistance at 20 °C | 13.1 Ω/km (conventional construction) |
| DC armor resistance at 20 °C | 9.84 Ω/km (conventional construction) |
| Minimum insulation resistance | 457 MΩ·km |
| Breaking strength, ends fixed | 3175 kg / 7000 lb (conventional construction) |
| Maximum working load | 1905 kg / 4200 lb (conventional construction) |
| Suggested minimum sheave diameter | 356 mm / 14 in |
| Outside diameter tolerance | 6.55 mm (+0.127 / -0.051 mm) |
| Insulation options | Polypropylene, ETFE, FEP/ETFE, PFA, or Q600 |
| Temperature range by insulation option | 149 °C to 315 °C |
Selection Guidance
Choose the insulation option according to the required temperature range and operating environment. Provide the intended working load, sheave size, well conditions, and required length so the TEBAOFLEX technical team can review the appropriate construction.
Request a Quote
Request a quote with the selected insulation type, working load, operating temperature, length, and application details.