The TEBAOFLEX (N)GFLCGÖU Screened Flat Festoon Cable is a flexible 300/500 V control cable for crane, lift, conveyor and festoon installations. Its flat profile supports compact routing, while the tinned copper braid screen helps reduce electromagnetic interference in control circuits.
Applications
- Crane and hoist festoon systems
- Lifts and elevators
- Floor conveyor and material-handling equipment
- Gantry crane systems where a flat cable profile is required
Key Features
- 300/500 V rated voltage for control and connection duties.
- EPR insulation and a black chloroprene rubber outer sheath for industrial service.
- Tinned copper wire braid screen for improved electromagnetic compatibility.
- Suitable for fixed installation from −50°C to +90°C and moving applications from −30°C to +90°C.
- Designed for festoon travel speeds up to 180 m/min; not intended for torsional service.
Construction and Technical Data
| Component | Specification |
|---|---|
| Conductor | Electrolytically annealed bare copper: Class 6 up to 25 mm²; Class 5 above 25 mm² |
| Insulation | EPR (ethylene propylene rubber) |
| Screen | Tinned copper wire braid |
| Outer sheath | Black CR chloroprene rubber, type 5GM3 |
| Rated voltage | 300/500 V |
| Minimum bending radius | 5 × overall diameter fixed; 10 × overall diameter moving |
| Maximum tensile load | 15 N/mm² |
| Conductor temperature | Maximum 90°C; maximum short-circuit temperature 250°C |
Indicative Current Ratings
| Number of Cores | Nominal Cross-Section | Permissible Current Rating |
|---|---|---|
| 4 | 1.5 mm² | 23 A |
| 4 | 2.5 mm² | 32 A |
| 4 | 4 mm² | 43 A |
| 4 | 6 mm² | 56 A |
| 4 | 10 mm² | 75 A |
| 4 | 16 mm² | 100 A |
| 4 | 25 mm² | 127 A |
| 4 | 35 mm² | 158 A |
| 4 | 50 mm² | 192 A |
| 4 | 70 mm² | 246 A |
| 8 | 1.5 mm² | 16 A |
| 12 | 1.5 mm² | 12 A |
| 12 | 2.5 mm² | 17 A |
Ratings are indicative and must be confirmed against the actual installation conditions, duty cycle and cable arrangement. For a tailored configuration or quotation, contact TEBAOFLEX with your core count, conductor size and travel requirements.