The 8.89 mm Armored Downhole Wireline Cable is an armored electrical cable for downhole logging, intervention, and well-service applications. Its construction combines a stranded copper conductor, insulation, and two mechanical armor layers to carry an electrical signal while supporting controlled deployment in the well. TEBAOFLEX can review the required load, sheave diameter, temperature, fluid exposure, and length before configuration selection.
Key Features
- Armored mono conductor construction for electrical continuity and mechanical support.
- Specified voltage, resistance, and tensile data for the documented configuration.
- Multiple insulation options where stated in the technical data, allowing selection by temperature requirement.
- Suitable for controlled wireline deployment where the selected load and sheave arrangement remain within the documented limits.
Downhole Application

Wireline systems are used to lower and retrieve downhole tools while providing a reliable electrical path. Installation should follow the selected cable’s documented load limits, bend guidance, and environmental requirements.
Technical Parameters
| Parameter | Specification |
|---|---|
| Center conductor | 15 AWG, 19 x 0.0142 in; 0.071 in / 1.80 mm nominal diameter |
| Insulation outside diameter | 0.136 in / 3.445 mm |
| Inner armor layer | 11 steel wires x 0.0455 in |
| Outer armor construction | See configuration table; armored OD 0.302 in / 7.67 mm |
| Jacketed overall diameter | 0.350 in / 8.89 mm |
| Rated voltage | 1500 VDC |
| DC conductor resistance at 20 °C | 2.8 Ω/kft / 9.2 Ω/km |
| DC armor resistance at 20 °C | 3.4 Ω/kft / 11.2 Ω/km |
| Minimum insulation resistance | 1500 MΩ·kft / 457 MΩ·km |
| Breaking strength, fixed ends | 8,500 lb / 3,630 kg |
| Maximum working load | 4,250 lb / 1,932 kg |
| Suggested minimum sheave diameter | 26 in / 660 mm |
| Outside diameter tolerance | +0.003 / -0.002 in; +0.076 / -0.051 mm |
| Temperature rating | 375 °F / 190 °C |
Configuration and Insulation Options
| Construction | Outer armor configuration | Insulation | Capacitance | Weight in air / water |
|---|---|---|---|---|
| Hybrid protective-jacket construction | Six bundles, each with 3 x 0.020 in strands; or six 0.040 in steel strands | FEP/ETFE | 56 pF/ft / 184 pF/m | 252 / 188 kg/km |
| Standard armored construction | 12 bundles, each with 3 x 0.0200 in steel strands | FEP/ETFE | 56 pF/ft / 184 pF/m | 245 / 180 kg/km |
Select the exact outer armor construction according to load, handling, and mechanical protection requirements. The two documented configurations are distinct and should be confirmed during the quotation review.
Selection Guidance
Match the exact conductor, armor material, insulation system, working load, sheave diameter, temperature, and well environment to the project requirement. The listed values are configuration-specific; confirm the final construction before purchasing.
Request a Quote
Request a quote with the required length, operating conditions, load, temperature range, and target configuration.