B101/B102/B103 Construction Lift Power and Control Cable

Hybrid construction lift power and control cable family for vertical drum, carriage and spring-drum applications. Available with flexible copper conductors, numbered control cores and power cores.

The B101/B102/B103 Construction Lift Power and Control Cable is a hybrid flexible cable family for vertical lifts used on construction sites. It combines power supply and numbered control circuits in one robust cable solution for lift platforms, tower installations and spring-drum systems.

Applications

Use this cable family to supply power and control vertical construction lifts during new-build and refurbishment projects. B101 is intended for drum-fed vertical drag-cable operation, B102 supports centre-fed carriage arrangements for greater heights, and B103 is designed for spring-loaded drum systems.

Construction and Performance

  • Extra-fine bare copper conductors for flexible movement.
  • Low-temperature flexible plastic core insulation and black special-plastic outer sheath.
  • Black numbered cores with a green-yellow protective conductor.
  • UV-resistant sheath; carriage configurations can include support braiding for enhanced resistance to wear, oil, hydrolysis and microbial attack.
  • Optional separate copper screening of control cores is available where the installation requires it.

Technical Parameters

ParameterSpecification
Control-core voltage300/500 V
Power-core voltage0.6/1 kV
AC test voltage, control cores1.5 kV at 50 Hz
AC test voltage, power cores3 kV at 50 Hz
Flexing temperature range-10°C to +80°C
Minimum bending radius10 x cable diameter
Sheath colourBlack

Available Configurations

VariantCore configurationApprox. outer diameterApprox. copper weightApprox. cable weight
B1015G2.5 + 10 x 1.020.0 mm220.0 kg/km306.0 kg/km
B1013G4 + 7 x 1.017.4 mm184.0 kg/km360.0 kg/km
B1014G6 + 10 x 1.021.0 mm340.0 kg/km575.0 kg/km
B1014G10 + 10 x 1.025.0 mm480.0 kg/km870.0 kg/km
B1014G16 + 6 x 1.026.1 mm700.0 kg/km1,250.0 kg/km
B1024G16 + 1 x 2.5 + 2 x 2 x 1.028.5 mm830.0 kg/km1,080.0 kg/km
B1024G25 + 1 x 2.5 + 2 x 2 x 1.033.4 mm1,176.0 kg/km1,500.0 kg/km
B1024G35 + 4 x 2.5 + 2 x 2 x 1.0 + 1 x 1.038.0 mm1,500.0 kg/km1,850.0 kg/km
B1034G2.5 + 3 x 1.013.0 mm125.0 kg/km230.0 kg/km
B1034G2.5 + 3 x 1.015.3 mm125.0 kg/km280.0 kg/km

Selection Support

Share your lift height, drum or carriage arrangement, required core configuration and installation conditions with TEBAOFLEX. Our team can help identify the appropriate B101, B102 or B103 configuration for your construction lift project.

Request a Quote

Model

B101 / B102 / B103

Rated Voltage

300/500 V control cores; 0.6/1 kV power cores

Conductor

Bare copper, extra-fine wire

Outer Sheath

Low-temperature flexible special plastic, black

Temperature Range

-10°C to +80°C (flexing)

Minimum Bending Radius

10 x cable diameter

Application

Vertical construction lifts